An effect of sampling rate to the time and frequency domain analysis of pulse rate variability

被引:0
|
作者
Yang Y.L. [1 ]
Shin H. [2 ]
机构
[1] Interdiciplanary Program of Biomedical Engineering, Chonnam National University
[2] Department of Biomedical Engineering, Chonnam National University
来源
Shin, Hangsik (hangsik.shin@jnu.ac.kr) | 1600年 / Korean Institute of Electrical Engineers卷 / 65期
关键词
Frequency domain analysis; Heart rate variability; Pulse rate variability; Sampling frequency; Time domain analysis;
D O I
10.5370/KIEE.2016.65.7.1247
中图分类号
学科分类号
摘要
This study aims to investigate the effect of sampling frequency to the time domain and frequency domain analysis of pulse rate variability (PRV). Typical time domain variables - AVNN, SDNN, SDSD, RMSSD, NN50 count and pNN50 - and frequency domain variables - VLF, LF, HF, LF/HF, Total Power, nLF and nHF - were derived from 7 down-sampled (250 Hz, 100 Hz, 50 Hz, 25 Hz, 20 Hz, 15 Hz, 10 Hz) PRVs and compared with the result of heart rate variability of 10 kHz-sampled electrocardiogram. Result showed that every variable of time domain analysis of PRV was significant at 25 Hz or higher sampling frequency. Also, in frequency domain analysis, every variable of PRV was significant at 15 Hz or higher sampling frequency. Copyright © The Korean Institute of Electrical Engineers.
引用
收藏
页码:1247 / 1251
页数:4
相关论文
共 50 条
  • [1] Time Domain And Frequency Domain Heart Rate Variability Analysis on Gyrocardiograms
    Siecinski, Szymon
    Kostka, Pawel S.
    Tkacz, Ewaryst J.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2630 - 2633
  • [2] EFFECT OF PROCAINAMIDE ON TIME AND FREQUENCY-DOMAIN ANALYSIS OF HEART-RATE-VARIABILITY
    BAILEY, JR
    CROSSLEY, GH
    SIMMONS, TW
    HAISTY, WK
    FITZGERALD, DM
    CIRCULATION, 1993, 88 (04) : 116 - 116
  • [3] Effect of EKG Sampling Rate on Heart Rate Variability Analysis
    Govindan, R. B.
    Massaro, An N.
    Kota, Srinivas
    Grabowski, Reagan C.
    Wilson, James D.
    du Plessis, Adre
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6780 - 6783
  • [4] Frequency Domain Analysis for Assessing Fluid Responsiveness by Using Instantaneous Pulse Rate Variability
    Lin, Pei-Chen
    Chang, Chia-Chi
    Hsu, Hung-Yi
    Hsiao, Tzu-Chien
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2016, 7 (02) : 229 - 233
  • [5] On the Minimal Adequate Sampling Frequency of the Photoplethysmogram for Pulse Rate Monitoring and Heart Rate Variability Analysis in Mobile and Wearable Technology
    Beres, Szabolcs
    Holczer, Lorine
    Hejjel, Laszlo
    MEASUREMENT SCIENCE REVIEW, 2019, 19 (05): : 232 - 240
  • [6] The influence of recording length on time and frequency domain analysis of heart rate variability
    Haaksma, J
    Dijk, WA
    Brouwer, J
    van den Berg, MP
    Dassen, WRM
    Mulder, B
    Crijns, HJGM
    COMPUTERS IN CARDIOLOGY 1998, VOL 25, 1998, 25 : 377 - 380
  • [7] Heart Rate Variability and Pulse Rate Variability: Do Anatomical Location and Sampling Rate Matter?
    Burma, Joel S.
    Griffiths, James K.
    Lapointe, Andrew P.
    Oni, Ibukunoluwa K.
    Soroush, Ateyeh
    Carere, Joseph
    Smirl, Jonathan D.
    Dunn, Jeff F.
    SENSORS, 2024, 24 (07)
  • [8] Sampling Rate Conversion in the Frequency Domain
    Bi, Guoan
    Mitra, Sanjit K.
    IEEE SIGNAL PROCESSING MAGAZINE, 2011, 28 (03) : 140 - 144
  • [9] On the Time Domain Error Caused By the Frequency Domain Sampling Rate in a Reverberation Chamber
    Xu, Jianhua
    Zhao, Yongjiu
    Xu, Qian
    IEEE ACCESS, 2019, 7 : 78223 - 78227
  • [10] JOINT TIME FREQUENCY DOMAIN ANALYSIS: A NOVEL APPROACH TO HEART RATE VARIABILITY RECOVERY
    Chatkoff, David K.
    Walter, Fawn A.
    Leonard, Michelle T.
    Maier, Karl J.
    Goetsch, Dianne M.
    Herman, Mindy E.
    PSYCHOSOMATIC MEDICINE, 2013, 75 (03): : A138 - A138