Sensitive fluorescent assay for copper(ii) determination in aqueous solution using quercetin-cyclodextrin inclusion

被引:0
|
作者
Yang S. [1 ,2 ]
Jiang W. [2 ,3 ]
Tang Y. [1 ,4 ]
Xu L. [2 ,5 ]
Gao B. [1 ]
Xu H. [3 ]
机构
[1] Advanced Analysis and Testing Center, Nanjing Forestry University, Nanjing
[2] Co-Innovation Center for Sustainable Forestry in Southern China, Nanjing Forestry University
[3] College of Chemical Engineering, Nanjing Forestry University
[4] College of Forestry, Nanjing Forestry University, Nanjing
[5] College of Science, Nanjing Forestry University, Nanjing
关键词
Compendex;
D O I
10.1039/C8RA06754F
中图分类号
学科分类号
摘要
Environmentally friendly probe materials for detecting copper ions were studied in this research. Fluorescent emission of quercetin (Q) was observed in the buffer solution (pH = 7.40), and (2-hydroxypropyl)-β-cyclodextrin (CD) could enhance the fluorescence intensity of Q. The UV/Vis spectrum showed that the Q-CD system was formed. After adding copper ions into the Q-CD system, the fluorescent emission intensity of Q-CD system generated quenching, and other metal ions could not bring change, which meant the Q-CD system showed good selectivity to copper ions. The fluorescence titration spectra showed that the concentration of copper ions was inversely proportional to fluorescence intensity, and gave a good linear change in fluorescence emission intensity in response to the concentration of copper ions ranging from 5.0 × 10−8 to 8.3 × 10−6 mol L−1. The calibration curve of the relationship between the intensity and copper ions concentration was y = −9.24x + 844.51 (R2 = 0.997). The detection limit of copper ions was measured to be 2.3 × 10−8 mol L−1. The probable mechanism was studied by UV/Vis spectrum and Job's plot method. The results indicated that Q-CD-Cu(ii) complex was formed and intramolecular charge transfer (ICT) took place. At last, the probe was successfully applied for determination of copper ions in water bodies, vegetables and fruits with good recovery. The study showed that Q-CD system could detect copper ions as a fluorescent probe with high selectivity, sensitivity and larger linearity range. © The Royal Society of Chemistry.
引用
收藏
页码:37828 / 37834
页数:6
相关论文
共 50 条
  • [1] Sensitive fluorescent assay for copper(II) determination in aqueous solution using quercetin-cyclodextrin inclusion
    Yang, Shilong
    Jiang, Weina
    Tang, Ying
    Xu, Li
    Gao, Buhong
    Xu, Haijun
    RSC ADVANCES, 2018, 8 (66): : 37828 - 37834
  • [2] Sensitive Fluorescent Assay for Determination of Cu2+ in Aqueous Solution Using Isorhamnetin-β-cyclodextrin Inclusion
    Yang Shi-Long
    Jiang Wei-Na
    Tang Ying
    Xu Li
    Gao Bu-Hong
    Xu Hai-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (06) : e19059 - e19065
  • [3] Sensitive fluorescent assay for copper (II) determination in aqueous solution using copper-specific ssDNA and Sybr Green I
    Zhan, Shenshan
    Xu, Hanchu
    Zhang, Weilin
    Zhan, Xuejia
    Wu, Yuangen
    Wang, Lumei
    Zhou, Pei
    TALANTA, 2015, 142 : 176 - 182
  • [4] Isorhamnetin-cyclodextrin inclusion: Sensitive fluorescent probe for copper (II)
    Yang, Shilong
    Xu, Li
    Sun, Xu
    Xue, Huayu
    Chen, Jichao
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [5] Determination of SDS Using Fluorescent γ-Cyclodextrin Based on TICT in Aqueous Solution
    Oka, Yoshikazu
    Nakamura, Shinnosuke
    Uetani, Yusuke
    Morozumi, Tatsuya
    Nakamura, Hiroshi
    ANALYTICAL SCIENCES, 2012, 28 (10) : 973 - 978
  • [6] Determination of SDS Using Fluorescent γ-Cyclodextrin Based on TICT in Aqueous Solution
    Yoshikazu Oka
    Shinnosuke Nakamura
    Yusuke Uetani
    Tatsuya Morozumi
    Hiroshi Nakamura
    Analytical Sciences, 2012, 28 : 973 - 978
  • [7] Highly sensitive and selective fluorescent probe for determination of Cu(II) in aqueous solution
    Yue, Yong-Kang
    Yin, Cai-Xia
    Huo, Fang-Jun
    JOURNAL OF COORDINATION CHEMISTRY, 2014, 67 (12) : 2039 - 2047
  • [8] Sensitive fluorescent chemosensor for Hg(II) in aqueous solution using 4’-dimethylaminochalcone
    Marco Mellado
    Nicole Roldán
    Rodrigo Miranda
    Luis F. Aguilar
    Manuel A. Bravo
    Waldo Quiroz
    Journal of Fluorescence, 2022, 32 : 1449 - 1456
  • [9] Sensitive fluorescent chemosensor for Hg(II) in aqueous solution using 4'-dimethylaminochalcone
    Mellado, Marco
    Roldan, Nicole
    Miranda, Rodrigo
    Aguilar, Luis F.
    Bravo, Manuel A.
    Quiroz, Waldo
    JOURNAL OF FLUORESCENCE, 2022, 32 (04) : 1449 - 1456
  • [10] A Zinc(II) Schiff Base Complex as Fluorescent Chemosensor for the Selective and Sensitive Detection of Copper(II) in Aqueous Solution
    Oliveri, Ivan Pietro
    Attina, Agostino
    Di Bella, Santo
    SENSORS, 2023, 23 (08)