CONCRETE CONE FAILURE CAPACITY OF POST-INSTALLED ANCHORS ADHERED TO FROST-DAMAGED CONCRETE

被引:0
|
作者
Yuga Y. [1 ]
Yuya T. [2 ]
Takahide A. [3 ]
Muneomi T. [4 ]
Taito S. [1 ]
Yutaro I. [3 ]
Tsutomu I. [4 ]
机构
[1] Division of Sustainable and Environmental Engineering, Muroran Institute of Technology
[2] College of Design and Manufacturing Technology, Muroran Institute of Technology
[3] Research Institute of Technology, TOBISHIMA Corporation
[4] Sales Engineering Division, Hilti Japan, Ltd
关键词
Cone failure; Frost-damage deterioration; Post-installed anchors;
D O I
10.3130/aijt.30.757
中图分类号
学科分类号
摘要
Although post-installed anchors are used for seismic reinforcement and installation of equipment, there is concern that the anchorage performance of anchor bolts anchored to base concrete with a surface layer that has been subjected to frost-damage will deteriorate. In this study, pull-out tests of post-installed anchors anchored to a specimen with a simulated surface layer subjected to frost-damaged concrete were conducted to investigate cone fracture of concrete. The results showed that the tensile strength of the deteriorated specimens was lower than that of the non-damaged specimens. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:757 / 761
页数:4
相关论文
共 50 条
  • [1] Performance of Post-Installed Anchors in a Progressively Damaged Concrete Shear Wall
    Faraone, Gloria
    Hutchinson, Tara C.
    Piccinin, Roberto
    Silva, John
    ACI STRUCTURAL JOURNAL, 2019, 116 (06) : 293 - 306
  • [2] Post-installed anchors in concrete strengthened by post-installed reinforcement under tensile load
    Siamakani, Seyed Yaser Mousavi
    Sahamitmongkol, Raktipong
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2022, 26 (13) : 6563 - 6582
  • [3] Modeling and analysis of the shear capacity of adhesive anchors post-installed into uncracked concrete
    Gesoglu, Mehmet
    Guneyisi, Esra Mete
    Guneyisi, Erhan
    Yilmaz, Muhammet Enes
    Mermerdas, Kasim
    COMPOSITES PART B-ENGINEERING, 2014, 60 : 716 - 724
  • [4] Tensile and shear capacity of post-installed chemical adhesive anchors in lightweight concrete
    Du, Hongkai
    Wang, Haimeng
    Wang, Jinyu
    Wang, Yuandong
    Yang, Fuxiong
    STRUCTURES, 2024, 61
  • [5] Design Recommendations for Concrete Pryout Capacity of Headed Steel Studs and Post-Installed Anchors
    Jebara, Khalil
    Sharma, Akanshu
    Ozbolt, Josko
    CIVILENG, 2023, 4 (03): : 782 - 807
  • [6] Performance and design of post-installed large diameter anchors in concrete
    Wang, Dongpo
    Wu, Dongsheng
    Ouyang, Chaojun
    Zhai, Mingang
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 114 : 142 - 150
  • [7] Concrete cone failure of bonded anchors in thermally damaged concrete
    Hlavicka, Viktor
    Lubloy, Eva
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 171 : 588 - 597
  • [8] Residual bearing capacity of the frost-damaged reinforced concrete beams
    Hassanzadeh, Manouchehr
    NORDIC CONCRETE RESEARCH, 2015, 53 (02): : 69 - 72
  • [9] Tensile Capacity of Post-Installed Rebars in Concrete Structure
    Wang, Chi-Ping
    Wu, Shengmin
    Wang, Chih Kang
    Pan, Hong-Yu
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 289 - +
  • [10] Development and challenges in finite element modelling of post-installed anchors in concrete
    Neupane, Chandani Chandra
    Lee, Jessey
    Pokharel, Tilak
    Tsang, Hing-Ho
    Gad, Emad