Study on floor-response spectrum of nuclear power plants considering soil-structure interactions

被引:0
|
作者
Gao Y.-W. [1 ]
Wang T. [2 ]
Dai J.-W. [2 ]
Jin B. [2 ]
机构
[1] China Earthquake Disaster Prevention Centre, Beijing
[2] Institute of Engineering Mechanics, China Earthquake Administration, Key Laboratory of Earthquake Engineering and Engineering Vibration of China Earthquake Administration, Harbin
来源
Gongcheng Lixue/Engineering Mechanics | 2020年 / 37卷 / 10期
关键词
Floor response spectrum; Seismic intensity; Seismic margin analysis; Shaking table test; Soil-structure interaction;
D O I
10.6052/j.issn.1000-4750.2019.11.0675
中图分类号
学科分类号
摘要
Floor response spectrum plays an important role in the seismic design and in the seismic margin analysis for the facilities and pipes inside a nuclear power plant (NPP). This study presents the results of a set of shaking table tests on a scaled nuclear power plant structure of 1:25, with the underlying soil simulated by a multi-functional laminated shear container where the viscous-elastic boundary has been well reproduced. A group of 10 ground motion records are selected as the input. The peak ground accelerations (PGA) of these motions are scaled to the operational basis earthquake (OBE 0.15 g), the safely shutdown earthquake (SSE 0.30 g), and the ultimate earthquake beyond the design basis standard (ULE 0.75 g), respectively. Considering the soil-structure interaction, the change of floor response spectra caused by the input intensity has been studied. The standard input earthquake for floor response analysis suggested by the "Code for seismic design of nuclear power plants" is also discussed accordingly. According to the analysis of equipment response, it is revealed that the evaluation method of seismic margin of existing nuclear power plant equipment is conservative. Especially the equipment response ratio of 1/1.5 ~ 1.5, the existing seismic margin assessment method to obtain the equipment seismic margin may be less than the qualified ground motion. In order to obtain the true seismic margin of the equipment, it is suggested that these kinds of equipment should be analyzed in a more detail.s of equipment should be analyzed in a more detail. Copyright ©2020 Engineering Mechanics. All rights reserved.
引用
收藏
页码:116 / 124
页数:8
相关论文
共 22 条
  • [1] Liu Yanjun, Lin Gao, Li Jianbo, Et al., A direct method for computation of floor response spectrum of a nuclear power plant, World Earthquake Engineering, 27, 2, pp. 93-99, (2011)
  • [2] Li Zhongxian, Li Zhongcheng, Shen Wangxia, Sensitivity analysis for floor response spectra of nuclear reactor buildings [J], Nuclear Power Engineering, 26, 1, pp. 44-50, (2005)
  • [3] Li Jianbo, Lin Gao, Zhong Hong, Et al., Analyses of effect of parameter uncertainty in NPP design on computation of floor response spectra [J], Journal of Dalian University of Technology, 51, 5, pp. 725-730, (2011)
  • [4] Xie Junfei, The learning from the large scale Lotong soil-structure interaction experiments (I), World Earthquake Engineering, 3, pp. 41-52, (1993)
  • [5] Xie Junfei, The learning from the large scale Lotong soil-structure interaction experiments (II), World Earthquake Engineering, 4, pp. 49-59, (1993)
  • [6] EPRI-TR-103959, Methodology for Developing Seismic Fragilities, (1994)
  • [7] EPRI-1002988, Seismic Fragility Application Guide [R], (2002)
  • [8] A methodology for assessment of nuclear power plant seismic margin (Revision1), (1991)
  • [9] EPRI-1019200, Seismic Fragility Application Update Guide [R], (2002)
  • [10] Hu Xiaoying, Study on seismic margin of protection system cabinet for nuclear power plants [J], Nuclear Power Engineering, 35, 5, pp. 28-30, (2014)