Establishment and verification of theoretical model of fast measurement method for potential radon concentration in soil

被引:0
|
作者
机构
[1] Peng, Jun-Zhe
[2] Zhao, Gui-Zhi
[3] Xiao, De-Tao
[4] Fu, Yan
[5] Chen, Ze-Guang
[6] Fu, Shi
[7] Sun, Hao
来源
Zhao, G.-Z. (872853371@qq.com) | 1600年 / Atomic Energy Press卷 / 47期
关键词
Soil surveys - Radon;
D O I
10.7538/yzk.2013.47.05.0860
中图分类号
学科分类号
摘要
The potential radon concentration in soil (the maximum radon concentration in soil) is directly related to indoor radon levels, and the depth of direct measurement normally takes up to several meters. The measurement is very difficult, and it's necessary to find a way to get the potential radon concentration in soil fast. In this paper, a theoretical model which can get the potential radon concentration in soil fast by taking advantage of the radon concentration in the shallow soil and the radon exhalation rate of soil surface (dual-source method) was established and verified by experiments. The results prove that this model is reliable. The establishment of this model provides a foundation for the research of fast measurement method for the potential radon concentration in soil.
引用
收藏
相关论文
共 50 条
  • [1] Study on radon concentration measurement in soil
    Zhao, Gui-Zhi
    Xiao, De-Tao
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (03): : 583 - 587
  • [2] Soil gas radon concentration measurement in estimating the geogenic radon potential in Abeokuta, Southwest Nigeria
    Samuel, Tunde Daniel
    Farai, Idowu Peter
    Awelewa, Ayodele Samuel
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (02) : 55 - 58
  • [3] Measurement of radon potential from soil using a special method of sampling
    Cosma, Constantin
    Papp, Botond
    Moldovan, Mircea
    Cosma, Victor
    Cindea, Ciprian
    Suciu, Liviu
    Apostu, Adelina
    ACTA GEOPHYSICA, 2010, 58 (05) : 947 - 956
  • [4] Measurement of radon potential from soil using a special method of sampling
    Constantin Cosma
    Botond Papp
    Mircea Moldovan
    Victor Cosma
    Ciprian Cindea
    Liviu Suciu
    Adelina Apostu
    Acta Geophysica, 2010, 58 (5) : 947 - 956
  • [5] Fast measurement of radon concentration in water with Lucas cell
    Machaj, B
    Bartak, J
    NUKLEONIKA, 2004, 49 (01) : 29 - 31
  • [6] Intercomparison measurement of soil-gas radon concentration
    Neznal, M
    Neznal, M
    Smarda, J
    RADIATION PROTECTION DOSIMETRY, 1997, 72 (02) : 139 - 144
  • [7] Fast Measurement of Methanol Concentration in Ionic Liquids by Potential Step Method
    Hainstock, Michael L.
    Tang, Yijun
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 2015
  • [8] Measurement of radon concentration in soil gas of the city of Rivne (Ukraine)
    Lebed, O. O.
    Lysytsya, A., V
    Myslinchuk, V. O.
    Pryshchepa, A. M.
    Dejneka, O. Yu
    UKRAINIAN JOURNAL OF ECOLOGY, 2018, 8 (04): : 158 - 164
  • [9] ELECTRET METHOD FOR CONTINUOUS MEASUREMENT OF THE CONCENTRATION OF RADON IN WATER
    DUA, SK
    HOPKE, PK
    KOTRAPPA, P
    HEALTH PHYSICS, 1995, 68 (01): : 110 - 114
  • [10] Measurement of Radon concentration in the air of underground establishment with solid state track detector
    Deng Fuwei
    Guo Huiping
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, 2007, : 157 - 160