摘要
A VCSEL wavelength locked loop of CPT atomic clock was designed by using the method of VCSEL wavelength locking based on multi-wavelength Doppler absorption spectroscopy and the Cs D2 line was used as the reference frequency of VCSEL wavelength locking. The control precision of VCSEL wavelength locked loop is better than 0.000 6 nm, while the stability of VCSEL wavelength locked loop is better than 2.84×10-7, and the signal-to-noise of CPT is improved. The VCSEL wavelength locked loop is applied to the CPT atomic clock experiment system and the frequency stability test result shows that the performance of VCSEL wavelength locked loop can meet the needs of the CPT atomic clock. © 2017, Editorial Board of Atomic Energy Science and Technology. All right reserved.
引用
收藏
页码:1140 / 1144
页数:4
相关论文
共 11 条
  • [1] Wang X., Fan Q., Du Z., Et al., Numerical analysis of influence of laser parameters on CPT Rb clock signals, Journal of Time and Frequency, 31, 2, pp. 86-91, (2008)
  • [2] Vanier J., Atomic clock based on coherent population trapping: A review, Applied Physics B, 81, 4, pp. 421-442, (2005)
  • [3] Vanier J., Coherent population trapping for the realization of a small stable atomic clock, IEEE International Frequency Control Symposium & PDA Exhibition, pp. 424-434, (2002)
  • [4] Vanier J., Coherent population trapping in cesium: Dark lines and coherent microwave emission, Physical Review A, 58, 3, pp. 2345-2358, (1998)
  • [5] Vanier J., Audoinr C., The Quantum Physics of Atomic Frequency Standards, (1989)
  • [6] Vanier J., Practical realization of a passive coherent population trapping frequency standard, IEEE Transactions on Instrumentation & Measurement, 54, 6, pp. 92-99, (2004)
  • [7] Stec D.A.K., Cesium D line data, (2010)
  • [8] Vanier J., The passive optically pumped Rb frequency standard: The laser approach, Applied Physics Laser and Optics B, 87, 4, pp. 1346-1351, (2007)
  • [9] Vanier J., On the use of intensity optical pumping and coherent population trapping techniques in the implementation of atomic frequency standards, Transactions on Instrumentation & Measurement, 52, 3, pp. 822-831, (2001)
  • [10] HFAN-08.2.0: How to control and compensate a thermoelectric cooler (TEC)