Axial compressive behaviors of partial deteriorated strength concrete columns confined with CFRP

被引:0
|
作者
Wei, Hua [1 ,2 ]
Wu, Zhi-Min [1 ]
Guo, Xia [1 ]
机构
[1] State Key Laboratory of Coastal and Offshore Engineering, Dalian University of Technology, Dalian 116024, China
[2] Henan Provincial Communications Quality Control Institute, Zhengzhou 450006, China
关键词
Columns (structural) - Concretes - Compressive strength;
D O I
暂无
中图分类号
学科分类号
摘要
This paper aims to present an effective method to partial deteriorated strength columns, and to investigate the mechanical behavior of the defect part. Five groups of 150×150 mm×mm plain square columns are cast; each specimen has two different strengths, the lower strength in the middle segment and higher strength in both ends. The lower strength is to simulate the status of partial deteriorated region. Different layers of CFRP sheets have been wrapped just on the lower strength part to gain the reinforcement with CFRP sheets, and to verify the practicability of partial confinement. Specimens are subjected to monotonic axial compression until failure. Axial load, axial and transverse strains are measured to compare the different behaviors between the two parts. Experimental results show that partial confinement can significantly enhance the strength and the ductility of the deteriorated strength part, then, the load capacity of the whole column can be increased subsequently. Test data indicate that the ultimate load of the confined column is higher than that of the original column without deterioration; partial confinement on weakness is a feasible approach.
引用
收藏
页码:363 / 368
相关论文
共 50 条
  • [1] Axial compressive behaviors of partial deteriorated strength concrete columns confined with CFRP
    魏华
    吴智敏
    郭夏
    Journal of Harbin Institute of Technology, 2010, 17 (03) : 363 - 368
  • [2] Axial compressive behaviors of partial deteriorated strength concrete columns confined with CFRP
    魏华
    吴智敏
    郭夏
    Journal of Harbin Institute of Technology(New series), 2010, (03) : 363 - 368
  • [3] Axial Experiment on CFRP Confined Steel Reinforced Concrete Columns with Partial Deteriorated Strength
    Wei, Hua
    Wu, Zhimin
    Zhang, Peng
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2010, 29 (06) : 874 - 882
  • [4] Behavior of CFRP wrapped concrete columns with partial deteriorated strength
    Wei, Hua
    Li, Jisheng
    Guo, Xia
    MULTI-FUNCTIONAL MATERIALS AND STRUCTURES, PTS 1 AND 2, 2008, 47-50 : 1282 - +
  • [5] Experimental study on partially deteriorated strength concrete columns confined with CFRP
    Wei, Hua
    Wu, Zhimin
    Guo, Xia
    Yi, Fumin
    ENGINEERING STRUCTURES, 2009, 31 (10) : 2495 - 2505
  • [6] Axial Compressive Behavior of CFRP-Confined Expansive Concrete Columns
    Cao, Qi
    Tao, Jinju
    Ma, Zhongguo John
    Wu, Zhimin
    ACI STRUCTURAL JOURNAL, 2017, 114 (02) : 475 - 485
  • [7] Axial Compressive Performance of CFRP-Confined Corroded Reinforced Concrete Columns
    Chen, Xiaochuan
    Xi, Banglu
    Guo, Yang
    Liu, Hanghang
    Xu, Dan
    Zhang, Xun
    BUILDINGS, 2024, 14 (08)
  • [8] Axial compressive behavior of grouted concrete block masonry columns confined by CFRP jackets
    Alotaibi, Khalid Saqer
    Galal, Khaled
    COMPOSITES PART B-ENGINEERING, 2017, 114 : 467 - 479
  • [9] New empirical approaches for compressive strength assessment of CFRP confined rectangular concrete columns
    Sharifi Y.
    Moghbeli A.
    Composite Structures, 2021, 262
  • [10] Compressive behavior of CFRP-confined partially encased concrete columns under axial loading
    Liang, Jiong-Feng
    Zou, Wan-Jie
    Wang, Zeng-Liang
    Liu, Da-wei
    COMPOSITE STRUCTURES, 2019, 229