A phase extraction algorithm in wavelength tuning interferometry

被引:0
|
作者
Liu, Jian [1 ]
Tian, Ailing [1 ]
Liu, Bingcai [1 ]
Wang, Hongjun [1 ]
机构
[1] Liu, Jian
[2] Tian, Ailing
[3] Liu, Bingcai
[4] Wang, Hongjun
来源
Tian, A. (tian21964@sohu.com) | 1600年 / Chinese Optical Society卷 / 34期
关键词
Calibration - Extraction - Iterative methods;
D O I
10.3788/AOS201434.0312001
中图分类号
学科分类号
摘要
Phase extraction precision directly affects the accuracy of phase-shift interferometry. In the wavelength tuning interferometry, a phase calibration is necessary for the test system, because phase shift is determined by interference cavity length and wavelength variation. But an accurate phase calibration is not easy to achieve. The phase shift error can be caused by an inaccurate calibration, which can decrease the phase extraction precision. A phase extraction algorithm based on iteration is proposed. This iteration algorithm does not need to calibrate the phase of the test system, and it can obtain the testing phase and phase shifts through alternate iteration method under the condition that the testing phase and phase shift are unknown. A series of simulations are done to compare the phase extraction accuracy, and the results suggest that the phase extraction accuracy of the proposed algorithm is quite better than that of the traditional four-step phase shift algorithm.
引用
收藏
相关论文
共 50 条
  • [1] Design of new window function of phase extraction algorithm in wavelength tuning Fizeau interferometer
    Kim, Yangjin
    Hibino, Kenichi
    Sugita, Naohiko
    Mitsuishi, Mamoru
    INTERFEROMETRY XVII: TECHNIQUES AND ANALYSIS, 2014, 9203
  • [2] Carrier squeezing interferometry with π/2 phase shift at the synthetic wavelength: Phase extraction in simultaneous dual-wavelength interferometry
    Cheng, Jinlong
    Yuan, Qun
    Chen, Ming
    Hu, Jie
    Yao, Yanxia
    Huang, Jialing
    Yang, Zhongming
    Gao, Zhishan
    OPTICS AND LASERS IN ENGINEERING, 2018, 107 : 288 - 298
  • [3] Carre Phase Shifting Algorithm for Wavelength Scanning Interferometry
    Muhamedsalih, Hussam
    Tang, Dawei
    Kumar, Prashant
    Jiang, Xiangqian
    MACHINES, 2022, 10 (02)
  • [4] An accurate phase shift extraction algorithm for phase shifting interferometry
    Zhai, Zhongsheng
    Zhou, Li
    Zhang, Yanhong
    Dong, Zhengqiong
    Wang, Xuanze
    Lv, Qinghua
    OPTICS COMMUNICATIONS, 2018, 429 : 144 - 151
  • [5] A self-tuning phase-shifting algorithm for interferometry
    Estrada, Julio C.
    Servin, Manuel
    Quiroga, Juan. A.
    OPTICS EXPRESS, 2010, 18 (03): : 2632 - 2638
  • [6] Generalized experimental phase extraction algorithm for speckle interferometry
    Barcelata-Pinzon, A.
    Meneses Fabian, C.
    Juarez-Salazar, R.
    Robledo Sanchez, C. I.
    Duran-Sanchez, M.
    Alvarez-Tamayo, R. I.
    PRACTICAL HOLOGRAPHY XXIX: MATERIALS AND APPLICATIONS, 2015, 9386
  • [7] In vivo intraocular ranging by wavelength tuning interferometry
    Hitzenberger, CK
    Kulhavy, M
    Lexer, F
    Baumgartner, A
    Fercher, AF
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS II, PROCEEDINGS OF, 1998, 3251 : 47 - 51
  • [8] Wavelength-tuning interferometry of intraocular distances
    Lexer, F
    Hitzenberger, CK
    Fercher, AF
    Kulhavy, M
    APPLIED OPTICS, 1997, 36 (25): : 6548 - 6553
  • [9] Absolute interferometry for surface shapes with large steps by wavelength tuning with a mechanical phase shift
    Hibino, Kenichi
    Tani, Yosuke
    Takatsuji, Toshiyuki
    Bitou, Youichi
    Warisawa, Shinichi
    Mitsuishi, Mamoru
    INTERFEROMETRY XIII: TECHNIQUES AND ANALYSIS, 2006, 6292
  • [10] Error analysis and comparison of wavelength tuning phase shifting interferometry of transparent optical flats
    Chang, Lin
    Gao, Jiehua
    Yu, Yingjie
    AOPC 2023:OPTIC FIBER GYRO, 2023, 12968