Deviation of geometric parameter from its design value of cone-beam computed tomography (CT) would result in image quality degradation. An analytical geometric parameter calibration method for cone-beam CT system was developed to improve the accuracy. The algorithm uses few assumptions, a simple calibration phantom and several projections to analytically estimate the geometric CT parameters. Simulations and experiments demonstrate that the algorithm is very accurate with the offset of the projection position of the rotation center being less than 0.1 pixel. A sensitivity analysis shows the robustness of the algorithm which is easy to implement and of great practical significance.
引用
收藏
页码:418 / 421
相关论文
共 50 条
  • [1] Iterative geometric parameter calibration algorithm for the helical trajectory in cone-beam CT
    Han, Yu
    Yan, Bin
    Li, Lei
    Li, Yongli
    Li, Jianxin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2013, 34 (07): : 1573 - 1580
  • [2] An Analytical Geometric Calibration Method for Circular Cone-Beam Geometry
    Xu, Jingyan
    Tsui, Benjamin M. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (09) : 1731 - 1744
  • [3] An analytic geometric calibration method for circular cone-beam CT
    Xu, Jingyan
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [4] GEOMETRIC CALIBRATION OF A CONE-BEAM CT SYSTEM WITHOUT EPID
    Vingerhoets, R.
    Wopereis, A.
    Welleweerd, H.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S434 - S434
  • [5] An interval subdividing based method for geometric calibration of cone-beam CT
    Tan, Shengqi
    Cong, Peng
    Liu, Ximing
    Wu, Zhifang
    NDT & E INTERNATIONAL, 2013, 58 : 49 - 55
  • [6] Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT
    Zhao, Jintao
    Hu, Xiaodong
    Zou, Jing
    Hu, Xiaotang
    SENSORS, 2015, 15 (09) : 22811 - 22825
  • [7] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [8] Geometric misalignment and calibration in cone-beam tomography
    von Smekal, L
    Kachelriess, M
    Stepina, E
    Kalender, WA
    MEDICAL PHYSICS, 2004, 31 (12) : 3242 - 3266
  • [9] Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    Daly, M. J.
    Siewerdsen, J. H.
    Cho, Y. B.
    Jaffray, D. A.
    Irish, J. C.
    MEDICAL PHYSICS, 2008, 35 (05) : 2124 - 2136
  • [10] Study on the geometric calibration method for static cone-beam CT imaging system
    Huang, Qiuhong
    Cao, Guohua
    Zhao, Min
    Qiu, Zongming
    Zhu, Lingjian
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2015, 36 (10): : 2339 - 2346