Peri-Implant Tissue Stability: A Series of Five Case Reports on an Innovative Implant Design

被引:0
|
作者
Bianchini, Marco Aurelio [1 ]
Escobar, Mario [1 ,2 ]
Galarraga-Vinueza, Maria Elisa [3 ,4 ]
Balduino, Thalles Yurgen [1 ]
Gehrke, Sergio Alexandre [5 ,6 ]
机构
[1] Fed Univ Santa Catarina UFSC, Ctr Educ & Res Dent Implants CEPID, Dept Dent, BR-88040900 Florianopolis, Brazil
[2] Santiago Guayaquil Catholic Univ UCSG, Dept Dent, Guayaquil 090615, Ecuador
[3] Tufts Univ, Dept Prosthodont, Sch Dent Med, Boston, MA 02111 USA
[4] Univ Amer UDLA, Sch Dent, Quito 170125, Ecuador
[5] Univ Miguel Hernandez Elche, Dept Bioengn, Alicante 03202, Spain
[6] Univ Catolica Murcia, Dept Implantol, Bioface Postgrad Odontol, Montevideo 11100, Uruguay
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 18期
关键词
dental implants; clinical cases; new implant design; bone level; keratinized mucosa; KERATINIZED MUCOSA; DENTAL IMPLANTS; FOLLOW-UP; HEALTH; SOFT; IMPACT; WIDTH; HARD;
D O I
10.3390/app14188354
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background/Aim: The stability of peri-implant tissues is crucial for the long-term success of dental implant treatments. A new cervical implant design has been developed to address the challenges associated with peri-implant tissue stability, featuring a concave cervical portion to increase tissue volume in this area. The present study aimed to clinically evaluate the effectiveness of the new cervical implant design in maintaining peri-implant tissue stability. Materials and Methods: Five clinical cases involving completely edentulous patients were selected, in which 25 implants were installed. The marginal bone level around each implant was assessed at three different time points-T0: immediately after the prosthesis installation, T1: 6 months post installation, and T2: at the last control visit, up to 38 months later. Measurements were taken to analyze changes in marginal bone levels (MBLs) and the keratinized mucosa (KM) over time. Furthermore, the keratinized mucosa (KM) around the implants was evaluated. Results: The mean and standard deviation values of the marginal bone levels at each time point were as follows-T0: 0.59 +/- 0.55 mm; T1: 1.41 +/- 0.59 mm; T2: 1.76 +/- 0.69 mm. Statistical analysis showed significant differences across the time points (ANOVA p < 0.0001). The overall mean KM values were 3.85 mm for T1 and T2, showing the stability of the peri-implant soft tissues at >= 1-year controls. Conclusion: Within the limitations of the present study, the results showed that the Collo implants presented measured MBL values increasing within the time range analyzed in each case but within the normal values cited in the literature for these types of rehabilitation treatments. However, the measured KM values presented, in all cases, an average above the values referenced in the literature as a minimum for maintaining the health of the peri-implant tissues.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Revisiting peri-implant soft tissue - histopathological study of the peri-implant soft tissue
    Silva, Eduarda
    Felix, Sergio
    Rodriguez-Archilla, Alberto
    Oliveira, Pedro
    dos Santos, Jose Martins
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2014, 7 (02): : 611 - 618
  • [2] Peri-Implant Mucosal Creeping: Two Case Reports
    Parra, Carlos
    Capri, Diego
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2018, 38 (02) : 227 - 233
  • [3] Peri-implant tissue conditions at implants treated with Sub-periosteal Peri-implant Augmented Layer technique: A retrospective case series
    Trombelli, Leonardo
    Pramstraller, Mattia
    Severi, Mattia
    Simonelli, Anna
    Farina, Roberto
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (10) : 992 - 1001
  • [4] Apoptosis in peri-implant tissue
    Stea, S
    Visentin, M
    Granchi, D
    Cenni, E
    Ciapetti, G
    Sudanese, A
    Toni, A
    BIOMATERIALS, 2000, 21 (13) : 1393 - 1398
  • [5] Impact of implant surfaces on peri-implant hard tissue
    Stadlinger, B.
    Belibasakis, G. N.
    Bierbaum, S.
    MKG-CHIRURG, 2014, 7 (04): : 281 - 299
  • [6] Influence of peri-implant bone quality on implant stability
    Schiuma, Damiano
    Plecko, Michael
    Kloub, Martin
    Rothstock, Stephan
    Windolf, Markus
    Gueorguiev, Boyko
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (01) : 82 - 87
  • [7] The influence of peri-implant keratinized mucosa on brushing discomfort and peri-implant tissue health
    Souza, Andre B.
    Tormena, Mariana
    Matarazzo, Flavia
    Araujo, Mauricio G.
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (06) : 650 - 655
  • [8] Influence of Implant transmucosal design on early peri-implant tissue responses in beagle dogs
    Huh, Jung-Bo
    Rheu, Gun-Bak
    Kim, Young-Soo
    Jeong, Chang-Mo
    Lee, Jeong-Yeol
    Shin, Sang-Wan
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 962 - 968
  • [9] Influence of Implant Neck Design on Peri-Implant Tissue Dimensions: A Comparative Study in Dogs
    Luis Calvo-Guirado, Jose
    Jimenez-Soto, Raul
    Perez Albacete-Martinez, Carlos
    Fernandez-Dominguez, Manuel
    Alexandre Gehrke, Sergio
    Eduardo Mate-Sanchez de Val, Jose
    MATERIALS, 2018, 11 (10)
  • [10] Healing of Peri-Implant Tissue following Flapless Implant Surgery
    Bagde, Hiroj
    Pawar, Sangeeta K.
    Hotchandani, Kamal
    Malik, Nida
    Awasthi, Vijaya
    Patil, Mohit V.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1139 - S1141