Low-powered microwave thermospray nebulizer for inductively coupled plasma atomic emission spectrometry

被引:0
|
作者
Ding, Lan [1 ]
Liang, Feng [2 ]
Huan, Yanfu [2 ]
Cao, Yanbo [2 ]
Zhang, Hanqi [2 ]
Jin, Qinhan [2 ]
机构
[1] Center of Analysis and Test, Jilin University, Changchun 130023, China
[2] Department of Chemistry, Jilin University, Changchun 130023, China
来源
| 1600年 / Royal Soc of Chemistry, Cambridge, United Kingdom卷 / 15期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] A low-powered microwave thermospray nebulizer for inductively coupled plasma atomic emission spectrometry
    Ding, L
    Liang, F
    Huan, YF
    Cao, YB
    Zhang, HQ
    Jin, QH
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (03) : 293 - 296
  • [2] A microwave powered thermospray nebulizer for liquid sample introduction in inductively coupled plasma atomic emission spectrometry
    Bordera, L
    Todoli, JL
    Mora, J
    Canals, A
    Hernandis, V
    ANALYTICAL CHEMISTRY, 1997, 69 (17) : 3578 - 3586
  • [3] A novel low microwave-powered thermospray nebulizer for liquid sample introdution in inductively coupled plasma atomic emission spectrometry
    Ding, L
    Jin, HY
    Xu, WQ
    Liang, F
    Cao, YB
    Jin, QH
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1999, 20 (12): : 1874 - 1876
  • [4] Aerosol desolvation studies with a thermospray nebulizer coupled to inductively coupled plasma atomic emission spectrometry
    Mora, J
    Todolí, JL
    Rico, I
    Canals, A
    ANALYST, 1998, 123 (06) : 1229 - 1234
  • [5] Comparison of a low microwave-powered thermospray nebulizer and a meinhard-pneumatic nebulizer for inducrively coupled plasma-atomic emission spectrometry
    Ding, L
    Wang, ST
    Ren, NQ
    Zhang, HQ
    Jin, QH
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (12) : 1458 - 1461
  • [6] A LOW CONSUMPTION THERMOSPRAY NEBULIZER WITH A FUSED-SILICA VAPORIZER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    ELGERSMA, JW
    MAESSEN, FJMJ
    NIESSEN, WMA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (11) : 1217 - 1220
  • [7] USE OF A THERMOSPRAY NEBULIZER AS A SAMPLE INTRODUCTION SYSTEM FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    VERMEIREN, KA
    TAYLOR, PDP
    DAMS, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (04) : 383 - 387
  • [8] Modified Babington Nebulizer for Inductively Coupled Plasma Atomic Emission Spectrometry
    Hirofumi Isoyama
    Tetsuo Uchida
    Takashi Nagashima
    Osamu Ohira
    Analytical Sciences, 2003, 19 : 593 - 598
  • [9] Sonic Spray Nebulizer for Inductively Coupled Plasma Atomic Emission Spectrometry
    Min Huang
    Hisao Kojima
    Atsumu Hirabayashi
    Hideaki Koizumi
    Analytical Sciences, 1999, 15 : 265 - 268
  • [10] THE CONESPRAY NEBULIZER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    IVALDI, JC
    VOLLMER, J
    SLAVIN, W
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (6-7) : 1063 - 1072