Study on the improvement of air conditioning system using mathematical principle method control technology

被引:0
|
作者
Yoshida Y. [1 ]
Fujinuma Y. [2 ]
机构
[1] Tokyo University of Science, Collaborating Researcher, National Institute for Environmental Studies
关键词
BAC-net; BEMS; Energy saving; Improvement; Office model; VAX System;
D O I
10.3130/aije.75.455
中图分类号
学科分类号
摘要
Building and Energy Management System (BEMS) has being focused on climate change mitigation in the 1PCC 4th report, in order to reduce Co 2 emissions in commercial sector in Japan, the project driven by NIES, National Institute for Environmental Studies, has developed the next generation BEMS that is configured with the environment measurement, the calculation of building energy and mathematical planning, and equipment control. This study is performed as a part of air conditioning control system development by real lime heat load and system simulation in the real building. Regional forecast weather data, number of persons staying in the room and electricity consumption are fed to this simulation for input data. Several sensors are set in this building for feeding input data of real time simulation. We studied the energy consumption of the office to simulate and forecast the energy saving and evaluated an office model using indoor air-conditioning control system. We tried to optimal control for the indoor office model.
引用
收藏
页码:455 / 464
页数:9
相关论文
共 50 条
  • [1] A study on control method of air conditioning system using occupants' thermal requests
    New Product Technologies Development Department, Matsushita Electric Works, Ltd., Japan
    不详
    不详
    J. Environ. Eng., 2008, 626 (535-542):
  • [2] Performance improvement of VAV air conditioning control system through diagonal matrix decoupling and Lonworks technology
    Wang, J
    Wang, Y
    Shao, HH
    ENERGY AND BUILDINGS, 2005, 37 (09) : 911 - 919
  • [3] The predictive control method of VAV air conditioning system
    Li, J. (814686683@qq.com), 1600, Universitas Ahmad Dahlan, Jalan Kapas 9, Semaki, Umbul Harjo,, Yogiakarta, 55165, Indonesia (11):
  • [4] Optimization Control Method of VAV Air Conditioning System
    Zhang, Xiaocheng
    Wang, Ronghao
    Xing, Jianchun
    PROCEEDINGS OF THE 2016 12TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2016, : 1105 - 1110
  • [5] Performance improvement of VAV air conditioning system through soft measurement technology
    Wang, Jun
    Wang, Yan
    Yan, Wei-Wu
    Shao, Hui-He
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2007, 41 (03): : 428 - 431
  • [6] Solar Air Conditioning System Using Desiccant Wheel Technology
    Rachman, Arfidian
    Mat, Sohif
    Iskandar, Taib
    Yahya, M.
    Zaharim, Azami
    Sopian, Kamaruzzaman
    SELECTED TOPICS IN SYSTEM SCIENCE AND SIMULATION IN ENGINEERING, 2010, : 419 - 423
  • [7] A Study on Fuzzy Control Technology of Constant Temperature and Constant Humidity Air-Conditioning System
    Kan, Ankang
    Han, Houde
    Ji, Jun
    Liu, Houmin
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 278 - 285
  • [8] Design of central air conditioning control system based on LonWorks technology
    Yang Liuqing
    Wang Qingyang
    Xu Bugong
    Chen Zhizhong
    Proceedings of the 24th Chinese Control Conference, Vols 1 and 2, 2005, : 1396 - 1398
  • [9] Development and Application of the Control Technology for VAV Air-conditioning System
    Yang, Shizhong
    Ren, Qingchang
    Li, Xia
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 543 - +
  • [10] Experimental study on the improvement of CO2 air conditioning system performance using an ejector
    Lee, Jae Seung
    Kim, Mo Se
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1614 - 1625