The partial volume effects (PVE) make the lesion distorted in PET images, which influences clinical diagnosis. A PVE correction method was set up in this study. According to the principle causing PVE, the relationships between the characteristic profiles of the transversal slice and the image of one dimension lesion were investigated based on a large of simulate experiment results for cylindrical lesions. The PVE correction for two dimension lesion image was simplified to perform with one dimension lesion image. It was named one dimension correction. Then the correction method was evaluated with the phantom study. Results: (1) One dimension correction method: The procedure of PVE correction consisted of three steps and the corrected value of lesion' size and radioactivity concentration were formulated. (2) Results of evaluation with the phantom study: The lesions' sizes and radioactivity concentrations were corrected satisfactorily, and the differences between the corrected and the true values were within 6% and 7% for the lesions larger than the system resolution (FWHM). For the smaller lesion, because of the heavier PVE there were much difference between the uncorrected and the true values of lesion' sizes and radioactivity concentrations, it reached more than 80%; it was reduced to about half after correction. A PVE correction approach for PET images of two dimension lesions, the one dimension correction, was proposed. It was simple and fast, and the correction results were satisfactory.
引用
收藏
页码:1231 / 1238
相关论文
共 50 条
  • [1] A simple correction method for the partial volume effect in Discovery STE PET/CT
    Mitsumoto, Tatsuya
    Mizoguchi, Noriko
    Himuro, Kazuhiko
    Sakaguchi, Yuichi
    Kaneko, Koichiro
    Onizuka, Yoshihiko
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [2] A recovery coefficient method for partial volume correction of PET images
    Srinivas, Shyam M.
    Dhurairaj, Thiruvenkatasamy
    Basu, Sandip
    Bural, Gonca
    Surti, Suleman
    Alavi, Abass
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (04) : 341 - 348
  • [3] A recovery coefficient method for partial volume correction of PET images
    Shyam M. Srinivas
    Thiruvenkatasamy Dhurairaj
    Sandip Basu
    Gonca Bural
    Suleman Surti
    Abass Alavi
    Annals of Nuclear Medicine, 2009, 23 : 341 - 348
  • [4] Correction for partial volume effect in PET blood flow images
    Gage, HD
    Fahey, FH
    Santago, P
    Harkness, BA
    Keyes, JW
    MEDICAL IMAGING 1996: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1996, 2709 : 244 - 253
  • [5] Partial Volume Correction in PET Images: A Single Correction Method Applied for Multiple Source to Background Ratios
    Piper, J.
    Shen, G.
    Nelson, A. D.
    Nelson, A. S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [6] Reproducibility of radiomics features in partial volume correction of PET images
    Azimi, Mohammad-Saber
    Kamali-Asl, Alireza
    Ay, Mohammad-Reza
    Hosseini, Mahboube Sadat
    Khorshidi, Fatemeh
    Arabi, Hossein
    Rahmim, Arman
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [7] Correction of partial volume effect of cerebral glucose metabolism images measured by PET/MRI
    Ito, Hiroshi
    Nambu, Takeyuki
    Matsubara, Keisuke
    Kubo, Hitoshi
    Oriuchi, Noboru
    Ishii, Shirou
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [8] Deriving resolution-compensated PET images from the GTM partial volume correction method
    Rousset, Olivier
    Nandi, Ayon
    Zhu, Yansong
    Rahmim, Arman
    Wong, Dean
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [9] Correction of partial volume effect in the projections in PET studies
    Guillette, Nicolas
    Sarrhini, Otman
    Lecomte, Roger
    Bentourkia, M'hamed
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3541 - 3543
  • [10] Regional deconvolution method for partial volume correction in brain PET
    Rusinek, H
    Tsuia, WH
    de Leon, MJ
    MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2001, 4321 : 409 - 418