Modified controls for grid-connected wind-turbine Doubly Fed Induction Generator under Unbalanced Voltage Dip for Torque Stability and Reduction of Current Harmonic

被引:0
|
作者
20144800261625
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
108927
引用
收藏
相关论文
共 50 条
  • [1] Modified Controls for Grid-Connected Wind-Turbine Doubly Fed Induction Generator under Unbalanced Voltage Dip for Torque Stability and Reduction of Current Harmonic
    Truc Pham-Dinh
    Hai Nguyen-Thanh
    Uchida, Kenko
    Nguyen Gia Minh Thao
    2014 PROCEEDINGS OF THE SICE ANNUAL CONFERENCE (SICE), 2014, : 1493 - +
  • [2] Comparison between Modifications of SFOC and DPC in Control of Grid-Connected Doubly Fed Induction Generator under Unbalanced Voltage Dip
    Truc Pham-Dinh
    Hai Nguyen-Thanh
    Uchida, Kenko
    Nguyen Gia Minh Thao
    2013 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2013, : 2581 - 2588
  • [3] Robust Current Control of Doubly Fed Wind Turbine Generator under Unbalanced Grid Voltage Conditions
    Wang, Yun
    Gong, Wenming
    Wu, Qiuwei
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [4] A Synergetic Control Approach to Grid-Connected, Wind-Turbine Doubly-Fed Induction Generators
    Yu, Xunwei
    Jiang, Zhenhua
    Zhang, Yu
    2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 2070 - 2076
  • [5] Modified Controls for Doubly Fed Induction Generator under Unbalanced Voltage Distortion for Torque Stability and PI-Fuzzy Controller
    Hai Nguyen-Thanh
    Cuong Vo-Viet
    PROCEEDINGS OF THE 2015 7TH IEEE INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS (CIS) AND ROBOTICS, AUTOMATION AND MECHATRONICS (RAM), 2015,
  • [6] Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    Brekken, Ted K. A.
    Mohan, Ned
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 129 - 135
  • [7] Adaptive Backstepping Control of Grid-Connected Doubly-Fed Induction Generator during Grid Voltage Dip
    Adekanle, Oluwaseun
    Guisser, M.
    Abdelmounim, E.
    Aboulfatah, M.
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES (ICEIT 2017), 2017,
  • [8] Modeling and control of wind-turbine driven doubly-fed induction generators under harmonic grid voltage conditions
    Xu, Hailiang
    Hu, Jiabing
    He, Yikang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (11): : 20 - 26
  • [9] Low Voltage Ride through Method to Enhance DC-link Voltage Stability in Grid-Connected Doubly Fed Induction Generator Wind Turbine
    Ngom, Ibrahima
    Mboup, Alioune Baadara
    Diop, Moustapha
    Ndiaye, Alphousseyni
    Thiam, Mouhamadou
    Thiaw, Lamine
    INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND ENERGY TECHNOLOGIES (ICECET 2021), 2021, : 384 - 388
  • [10] Stability Analysis and Control of a Grid Connected Wind Turbine Based on Doubly Fed Induction Generator
    Hassan, Marwa
    Stone, Oliver
    Monaco, Salvator
    El-Amary, Noha
    2019 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2019 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2019,