Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys

被引:0
|
作者
Song H. [1 ]
Ruan D. [2 ]
Liu W. [2 ]
Stenger V.A. [3 ]
Pohmann R. [4 ]
Fernández-Seara M.A. [5 ]
Nair T. [6 ]
Jung S. [7 ]
Luo J. [8 ]
Motai Y. [9 ]
Ma J. [1 ]
Hazle J.D. [1 ]
Gach H.M. [10 ]
机构
[1] Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, 77030, TX
[2] Departments of Radiation Oncology, Biomedical Physics and Bioengineering, UCLA, Los Angeles, 90095, CA
[3] Department of Medicine, University of Hawai’i at Manoa, Honolulu, 96813, HI
[4] High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tubingen
[5] Department of Radiology, University of Navarra Hospital, Pamplona
[6] DMC R&D Center, Samsung Electronics Inc., Seocho-gu, Seoul
[7] Department of Statistics, University of Pittsburgh, Pittsburgh, 15213, PA
[8] Department of Surgery, Washington University in St. Louis, St. Louis, 63110, MO
[9] Department of Electrical and Computer Engineering, Virginia Commonwealth University, Richmond, 23284, VA
[10] Departments of Radiation Oncology and Radiology, Washington University, St. Louis, 63110, MO
来源
Gach, H. Michael (gachhm@wustl.edu) | 1600年 / John Wiley and Sons Ltd卷 / 44期
基金
美国国家卫生研究院;
关键词
arterial spin label; artificial neural network; kidney; magnetic resonance imaging; respiratory motion prediction;
D O I
10.1002/MP.12099
中图分类号
学科分类号
摘要
Purpose: Respiratory motion prediction using an artificial neural network (ANN) was integrated with pseudocontinuous arterial spin labeling (pCASL) MRI to allow free-breathing perfusion measurements in the kidney. In this study, we evaluated the performance of the ANN to accurately predict the location of the kidneys during image acquisition. Methods: A pencil-beam navigator was integrated with a pCASL sequence to measure lung/di-aphragm motion during ANN training and the pCASL transit delay. The ANN algorithm ran concur-rently in the background to predict organ location during the 0.7-s 15-slice acquisition based on the navigator data. The predictions were supplied to the pulse sequence to prospectively adjust the axial slice acquisition to match the predicted organ location. Additional navigators were acquired immedi-ately after the multislice acquisition to assess the performance and accuracy of the ANN. The technique was tested in eight healthy volunteers. Results: The root-mean-square error (RMSE) and mean absolute error (MAE) for the eight volunteers were 1.91 ± 0.17 mm and 1.43 ± 0.17 mm, respectively, for the ANN. The RMSE increased with transit delay. The MAE typically increased from the first to last prediction in the image acquisi-tion. The overshoot was 23.58% ± 3.05% using the target prediction accuracy of ± 1 mm. Conclusion: Respiratory motion prediction with prospective motion correction was successfully demonstrated for free-breathing perfusion MRI of the kidney. The method serves as an alternative to multiple breathholds and requires minimal effort from the patient. © 2017 American Association of Physicists in Medicine.
引用
收藏
页码:962 / 973
页数:11
相关论文
共 50 条
  • [1] Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys
    Song, Hao
    Ruan, Dan
    Liu, Wenyang
    Stenger, V. Andrew
    Pohmann, Rolf
    Fernandez-Seara, Maria A.
    Nair, Tejas
    Jung, Sungkyu
    Luo, Jingqin
    Motai, Yuichi
    Ma, Jingfei
    Hazle, John D.
    Gach, H. Michael
    MEDICAL PHYSICS, 2017, 44 (03) : 962 - 973
  • [2] Patient specific prospective respiratory motion correction for efficient, free-breathing cardiovascular MRI
    Bush, Michael A.
    Ahmad, Rizwan
    Jin, Ning
    Liu, Yingmin
    Simonetti, Orlando P.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3662 - 3674
  • [3] Exploiting Quasiperiodicity in Motion Correction of Free-Breathing Myocardial Perfusion MRI
    Wollny, Gert
    Ledesma-Carbayo, Maria J.
    Kellman, Peter
    Santos, Andres
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (08) : 1516 - 1527
  • [4] Respiratory motion correction in free-breathing ultrasound image sequence for quantification of hepatic perfusion
    Zhang, Ji
    Ding, Mingyue
    Meng, Fan
    Yuchi, Ming
    Zhang, Xuming
    MEDICAL PHYSICS, 2011, 38 (08) : 4737 - 4748
  • [5] Arterial spin-labeled perfusion MRI in basic and clinical neuroscience
    Detre, John A.
    Wang, Jiongjiong
    Wang, Ze
    Rao, Hengyi
    CURRENT OPINION IN NEUROLOGY, 2009, 22 (04) : 348 - 355
  • [6] Real-Time Prediction in Free-Breathing Perfusion MRI
    Song, H.
    Liu, W.
    Ruan, D.
    Jung, S.
    Gach, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 440 - +
  • [7] Free-Breathing Myocardial Perfusion MRI Using SW-CG-HYPR and Motion Correction
    Ge, Lan
    Kino, Aya
    Griswold, Mark
    Carr, James C.
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (04) : 1148 - 1154
  • [8] Free-breathing pediatric MRI with nonrigid motion correction and acceleration
    Cheng, Joseph Y.
    Zhang, Tao
    Ruangwattanapaisarn, Nichanan
    Alley, Marcus T.
    Uecker, Martin
    Pauly, John M.
    Lustig, Michael
    Vasanawala, Shreyas S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 407 - 420
  • [9] BRAIN DEVELOPMENT OF ADHD USING ARTERIAL SPIN-LABELED PERFUSION MRI
    Lim, You Bin
    Park, So Hyun
    Song, Huijin
    Lee, Hyunjoo
    Kwon, Seo Young
    Sohn, Chul-Ho
    Do, Ryemi
    Kim, Bung-Nyun
    JOURNAL OF THE AMERICAN ACADEMY OF CHILD AND ADOLESCENT PSYCHIATRY, 2024, 63 (10): : S216 - S217
  • [10] Free-breathing Arterial Spin Labeling MRI for the Detection of Pulmonary Embolism
    Othman, Ahmed E.
    Liang, Cecilia
    Komma, Yasmin
    Munz, Max
    Kolb, Manuel
    Rath, Dominik
    Gueckel, Brigitte
    Pohmann, Rolf
    Nikolaou, Konstantin
    Schwartz, Martin
    Kuestner, Thomas
    Martirosian, Petros
    Seith, Ferdinand
    RADIOLOGY, 2023, 307 (03)