Potential accuracy of target coordinates determination in a bistatic angle-measuring passive system

被引:0
|
作者
Okhrimenko, A.G. [1 ]
机构
[1] Poltavskij Inst. Svyazi, Poltava, Ukraine
关键词
Computer simulation - Errors - Estimation - Radar measurement - Signal processing - Statistical methods;
D O I
暂无
中图分类号
学科分类号
摘要
Synthesis and analysis are carried out of joint estimates distribution density of the signal sources coordinates obtained with the help of measured azimuths processing in a bistatic system. The influence of signals source location, measurements accuracy and correlation on the passive system accuracy is studied. The recommendations are given on application of the obtained results.
引用
收藏
页码:40 / 45
相关论文
共 50 条
  • [1] Determination of coordinates of signal resources in angle-measuring passive location systems
    Okhrimenko, AG
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1998, 41 (11-12): : A31 - A36
  • [2] UNAMBIGUOUS ACCURACY OF AN INTERFEROMETER ANGLE-MEASURING SYSTEM
    KENDALL, WB
    IEEE TRANSACTIONS ON SPACE ELECTRONICS AND TELEMETRY, 1965, SE11 (02): : 62 - &
  • [4] Potential accuracy of the determination of target coordinates in 2-position goniometric passive systems
    Okhrimenko, AG
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 2002, 45 (11-12): : A40 - A45
  • [5] POTENTIAL ACCURACY OF THE ANGLE-MEASURING CHANNEL OF A COMPLEX RADIO SHORT-RANGE NAVIGATION SYSTEM.
    Papkov, A.I.
    Telecommunications and Radio Engineering (English translation of Elektrosvyaz and Radiotekhnika), 1983, 37-38 (03): : 87 - 89
  • [6] CCD precision angle-measuring system
    Wang, Fu
    Cheng, Shoucheng
    Liu, Bingqi
    Shen, Xueju
    Chinese Acad Sci, Sichuan, China (24):
  • [7] Error mechanism analysis and accuracy enhancement method for circular gratings angle-measuring system
    Li, Yuan-xi
    Ren, Shun-qing
    Liu, Qing -bo
    Wang, Chang-hong
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 370
  • [8] Comparison of target classification accuracy according to the aspect angle and the bistatic angle in bistatic sonar
    Choo, Yeon-Seong
    Byun, Sung-Hoon
    Choo, Youngmin
    Choi, Giyung
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2021, 40 (04): : 330 - 336
  • [9] EFFECT OF THE ROTOR PATTERN ON THE ACCURACY OF THE PHOTOELECTRIC ANGLE-MEASURING SYSTEM OF A GIMBALLESS ELECTROSTATIC GYROSCOPE.
    Koval, S.T.
    Klimchuk, L.S.
    Osmolovskiy, Yu.F.
    Sigida, Yu.A.
    1600, (39):
  • [10] ANGLE-MEASURING SYSTEM FOR TESTING PHOTOELECTRIC AUTOCOLLIMATION TELESCOPES
    BEYER, W
    PAHL, W
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1974, 82 (06): : 267 - 269