Calibration experiments of infrared detecting system with fixed focal length

被引:0
|
作者
Zou Q. [1 ]
Liu L. [1 ]
Chen Q. [1 ]
Xu Z. [1 ]
Chen J. [1 ]
Yao M. [1 ]
机构
[1] Luoyang Electronic Equipment Test Center, Luoyang
关键词
Calibration experiment; Calibration method; Infrared detecting system;
D O I
10.3788/IRLA201645.1204004
中图分类号
学科分类号
摘要
The calibration data are meaningful in measurement of infrared radiometric characteristics for target and its background. They also play an important role in IR imaging guiding simulation test application. The field radiometric calibration methods for infrared detecting system with fixed focal length are analyzed at first. Three kinds of methods were briefly introduced and compared, and the applicability of different methods was pointed out. In order to compare the characteristic change of three methods, short distance radiometric calibration, a certain distance radiometric calibration and radiometric calibration using of extended area blackbody and collimator were used in this research. And then the experiments by different radiometric calibration methods were investigated. The short distance radiometric calibration results show that it isn't suitable for infrared reconnaissance and warning detecting system. The certain distance radiometric calibration results show that it needs further calculation of environment radiation, path radiation and path transmission. Then, the environmental parameters is loaded in MODTRAN soft ware to predict environment radiation, path radiation and path transmission. But it's difficult to obtain very accurate calculating results. To measure the target radiation characteristics, radiometric calibration using of extended area blackbody and collimator is necessary. The research is useful for technical innovation of the out-field radiometric calibration of infrared detecting system. It also can be applied to system design of target characteristics measuring system. © 2016, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
引用
收藏
页数:5
相关论文
共 11 条
  • [1] Bai Y., Liao Z., Ji H., Et al., Application of the chalcogenide glass in modern infrared thermal imaging systems, Chinese Optics, 7, 3, pp. 449-454, (2014)
  • [2] Han G., Cao L., Zhang W., Design of ground-based optical radiation signature measurement system, Infrared and Laser Engineering, 43, 2, pp. 551-556, (2014)
  • [3] Liu D., Zhang G., Flight test measurement of infrared radiation characteristics of an airplane, Flight Test, 19, 2, pp. 22-26, (2003)
  • [4] Wei H., Chen X., Zhan J., Et al., Atmospher correction in the measurement of infrared radiance, Journal of Atmosphere and Environmental Optics, 2, 6, pp. 472-478, (2007)
  • [5] Han Y., Xuan Y., Effect of atmosphere trans-mission on IR radiation feature of target and background, Applied Optics, 23, 6, pp. 8-11, (2002)
  • [6] Li N., Zhang Y., Liu C., Et al., Calibration of 1 m aperture infrared theodolite, Optics and Precision Engineering, 22, 8, pp. 2054-2060, (2014)
  • [7] Sun Z., Chang S., Zhu W., Et al., Radiation calibration of infrared system by amendment of inner and outer calibrations, Optics and Precision Engineering, 22, 8, pp. 2254-2260, (2015)
  • [8] Sun Z., Chang S., Zhu W., Simplifying method of radiance calibration for MWIR detector, Infrared and Laser Engineering, 43, 7, pp. 2132-2137, (2015)
  • [9] Liu M., Wang S., He Y., Et al., Bullet radiation detection range analysis based on multiple infrared visual range prediction models, Chinese Optics, 8, 4, pp. 636-642, (2015)
  • [10] Wang Y., Huang J., Wei X., Infrared imaging simulation of space target in orbit, Infrared and Laser Engineering, 44, 9, pp. 2594-2597, (2015)