Noninvasive monitoring of intracranial pressure

被引:29
|
作者
Popovic, Djordje [1 ,3 ]
Khoo, Michael [1 ]
Lee, Stefan [2 ]
机构
[1] Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, United States
[2] Department of Neurosurgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States
[3] Advanced Brain Monitoring Inc., Carlsbad, CA, United States
来源
关键词
Acoustic emissions - Human resource management - Ultrasonics - Acoustic properties - Acoustic emission testing - Eye protection - Brain;
D O I
10.2174/1874764710902030165
中图分类号
学科分类号
摘要
Increased intracranial pressure (ICP) is one of the major causes of secondary brain ischemia that accompanies a variety of pathological conditions, most notably, traumatic brain injury (TBI), stroke, and intracranial hemorrhages. However, aside from a few Level I trauma centers, ICP monitoring is rarely a part of the clinical management of patients with these conditions because of the invasiveness of the standard monitoring methods (which require insertion of a catheter into the cranium), additional risks they present for patients, high costs associated with the procedure, and the limited access to trained personnel, i.e., a neurosurgeon. Alternative methods have therefore been sought with which ICP can be measured noninvasively. This article reviews nearly 30 such methods patented over the past 25 years, which included ultrasound time-of-flight techniques, transcranial Doppler, methods based on acoustic properties of the cranial bones, EEG, MRI, tympanic membrane displacement, oto-acoustic emission, ophthalmodynamometry, and ultrasound measurements of optic nerve sheath diameter. At present, none of the methods is sufficiently accurate to allow for routine clinical use although several hold promise. Future developments should integrate further refinements of the existing methods, combined use of multiple sensors and/or technologies, and large clinical validation studies on relevant populations. © 2009 Bentham Science Publishers Ltd.
引用
收藏
页码:165 / 179
相关论文
共 50 条
  • [1] Noninvasive monitoring of intracranial pressure
    Paulat, K
    Maur, U
    Brucher, R
    Russell, D
    STROKE, 2004, 35 (01) : 337 - 337
  • [2] The Future of Noninvasive Intracranial Pressure Monitoring
    Luis Pinedo-Portilla, Juan
    REVISTA DEL CUERPO MEDICO DEL HOSPITAL NACIONAL ALMANZOR AGUINAGA ASENJO, 2021, 14 (01): : 108 - 109
  • [3] NONINVASIVE INTRACRANIAL-PRESSURE MONITORING
    PITLYK, PJ
    PIANTANIDA, TP
    PLOEGER, DW
    NEUROSURGERY, 1985, 17 (04) : 581 - 584
  • [4] Review: pathophysiology of intracranial hypertension and noninvasive intracranial pressure monitoring
    Canac, Nicolas
    Jalaleddini, Kian
    Thorpe, Samuel G.
    Thibeault, Corey M.
    Hamilton, Robert B.
    FLUIDS AND BARRIERS OF THE CNS, 2020, 17 (01)
  • [5] Noninvasive intracranial pressure monitoring in women with migraine
    Rossi, Denise Martineli
    Bevilaqua-Grossi, Debora
    Mascarenhas, Sergio
    Dutra de Souza, Hugo Celso
    Carvalho, Gabriela Ferreira
    Carmona Vendramim, Ana Carolina
    Philbois, Stella Vieira
    Dach, Fabiola
    Tallarico, Francisco Jose
    de Oliveira, Anamaria Siriani
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Noninvasive intracranial pressure monitoring in women with migraine
    Denise Martineli Rossi
    Débora Bevilaqua-Grossi
    Sérgio Mascarenhas
    Hugo Celso Dutra de Souza
    Gabriela Ferreira Carvalho
    Ana Carolina Carmona Vendramim
    Stella Vieira Philbois
    Fabíola Dach
    Francisco José Tallarico
    Anamaria Siriani de Oliveira
    Scientific Reports, 12
  • [7] Review: pathophysiology of intracranial hypertension and noninvasive intracranial pressure monitoring
    Nicolas Canac
    Kian Jalaleddini
    Samuel G. Thorpe
    Corey M. Thibeault
    Robert B. Hamilton
    Fluids and Barriers of the CNS, 17
  • [8] Noninvasive Intracranial Pressure Monitoring: Are We There Yet?
    Rajajee, Venkatakrishna
    NEUROCRITICAL CARE, 2024, 41 (2) : 332 - 338
  • [9] NONINVASIVE MONITORING OF INTRACRANIAL-PRESSURE - FACT OR FANCY
    KAISER, AM
    WHITELAW, AGL
    DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 1987, 29 (03): : 320 - 326
  • [10] NONINVASIVE INTRACRANIAL PRESSURE MONITORING IN NICU - AN OBSERVATIONAL STUDY
    Pradeep, M.
    Pradeep, S.
    Embramadathil, D.