Design and test of short centerline probe in continuous transonic wind tunnel

被引:0
|
作者
Deng H. [1 ]
Xiong B. [1 ]
Luo X. [1 ]
Hong S. [1 ]
Li T. [1 ]
Zhang L. [1 ]
Han X. [1 ]
机构
[1] High Speed Aerodynamics Institute, China Aerodynamics Research and Development Center, Sichuan, Mianyang
来源
关键词
configuration design; flow quality; short centerline probe; transonic wind tunnel; wind tunnel test;
D O I
10.13224/j.cnki.jasp.20210109
中图分类号
学科分类号
摘要
Several types of short centerline probes were designed without need of cable fixa-tion. The characteristics of the measured values were studied by wind tunnel test. The results showed that the difference of Mach number root-mean-square deviation between short centerline probe and long centerline probe with different shape parameters was less than 0.0003,the difference of Mach number correction was less than 0.0008,and the measurement curve had no obvious change when the Mach number was below 0.95;There were great differences between short centerline probe and long centerline probe of different shape parameters When the Mach number was between 1.0 and 1.4,changing the shape parameters of short centerline probe or increasing probe length can reduce the interference of head to flow field to some extent. © 2022 BUAA Press. All rights reserved.
引用
收藏
页码:1171 / 1180
页数:9
相关论文
共 18 条
  • [1] pp. 282-283, (2003)
  • [2] (1991)
  • [3] JACKSON F M., Calibration of the AEDC-PWT 16-ft transonic tunnel at test section wall porosities of two, four, and six percent, (1976)
  • [4] REED T D., Calibration of transonic and supersonic wind tunnels, (1977)
  • [5] DICK R S., The influence of several cable-type supports upon the static pressures along the centerline tube in a transonic wind tunnel, (1955)
  • [6] JACKSON F M., Supplemental calibration results for the AEDC propulsion wind tunnel(l6T), (1970)
  • [7] LI Feng, GAO Chao, ZHANG Zhengke, Et al., The test of characteristics of flow area and calibration model in NF - 6 pressurized continuous transonic wind tunnel, Journal of Experiments in Fluid Mechanics, 27, 1, pp. 61-64, (2013)
  • [8] CHEN Dehua, WANG Weixin, WANG Jinjun, Et al., Investigation on flow-field debugging for 2.4 m transonic wind tunnel, Acta Aerodynamica Sinica, 22, 3, pp. 279-282, (2004)
  • [9] CHEN Dehua, WANG Ruibo, LIU Guangyuan, Et al., The test and flow field calibration of 2.4 m transonic wind tunnel slotted test section, Journal of Experiments in Fluid Mechanics, 27, 4, pp. 66-70, (2013)
  • [10] JACKSON C M, CORLETT W A, MONTA W J., Description and calibration of the Langley unitary plan wind tunnel, (1981)