Design of Reflective Optical Fiber Oil Contamination Detection Sensor

被引:0
|
作者
Zhang P. [1 ]
Liang J. [1 ]
Sun T. [1 ]
Tong K. [1 ]
机构
[1] School of Mechanical and Electrical Engineering, Xi'an University of Architecture and Technology, Xi'an
关键词
mathematical model; oil contamination; output characteristics; reflective optical fiber; sensor;
D O I
10.16450/j.cnki.issn.1004-6801.2023.04.009
中图分类号
学科分类号
摘要
In view of the fact that 70% of the faults of hydraulic equipment caused by oil contamination,solid particles are the main contamination. Most of the commonly used oil contamination detection technology and equipment have the status of complex structure,expensive price and inconvenient online detection. Herein,a reflective optical fiber oil contamination detection sensor is designed. According to the attenuation of light intensity caused by the blocking of light by contamination particles,combined with the propagation characteristics of light in liquid,the working principle of oil contamination degree reflective optical fiber detection is proposed. The mathematical model of the sensor is established according to the approximate Gaussian distribution of the optical field at the end of the optical fiber. The influence of different parameters on the output characteristics of the sensor is analyzed. The structure of the sensor probe is determined. The reflective optical fiber sensor for oil contamination detection is designed. Based on the sensor test platform,the standard oil is configured according to different contamination levels to verify the characteristics of the sensor. Experimental results show that the sensor can detect the hydraulic contaminated oil with different contamination level standards. © 2023 Nanjing University of Aeronautics an Astronautics. All rights reserved.
引用
收藏
页码:692 / 697+827
相关论文
共 17 条
  • [1] NG F,, HARDING J A,, GLASS J., Improving hydraulic excavator performance through in line hydraulic oil contamination monitoring[J], Mechanical Systems and Signal Processing, 83, pp. 176-193, (2017)
  • [2] WU Sailong, LIN Sen, REN Zhichao, Et al., Detection of hydraulic oil pollution degree based on optical fiber sensing[J], Fluid Transmission and Control, 5, pp. 27-30, (2016)
  • [3] KONG Lingren, LU Jixia, SU Zilong, Et al., Design of oil contamination detection system based on filter clogging[J], Lubrication and Sealing, 42, 3, pp. 107-110, (2017)
  • [4] ZENG L, ZHANG H P,, WANG Q,, Et al., Monitoring of non-ferrous wear debris in hydraulic oil by detecting the equivalent resistance of inductive sensors [J], Micromachines, 9, 3, pp. 1-8, (2018)
  • [5] REN Song, XU Xueru, OUYANG Xun, Et al., Oil intelligent analysis and health monitoring of rotary drilling rig equipment[J], Journal of Vibration,Measurement & Diagnosis, 40, 3, pp. 597-603, (2020)
  • [6] PENG Feng, WANG Liyong, WU Jianpeng, Et al., Development status and trend of on-line monitoring technology for oil-liquid abrasive particles[J], Equipment Management and Maintenance, pp. 26-28, (2016)
  • [7] Non-dispersive infrared sensor for online condition monitoring of gearbox oil[J], Sensors, 17, 2, pp. 399-408, (2017)
  • [8] WEN Huanxiao, FU Jingye, Study on the measurement of particle pollution in oil by photoresistance method[J], Aerospace Measurement Technology, 22, 6, pp. 38-41, (2002)
  • [9] XIONG Zilun, LU Jide, LI Qi, Et al., Using capacitors to verify the pollution degree of oil[J], Physics Experimentation, 38, 12, pp. 48-50, (2018)
  • [10] FAROOQ K,, FOWLER R., Comparison of water measurement results in polyol ester-based lubricating fluids determined by the coulometric Karl Fischer method and a thin-film polymer capacitive water sensor [J], Tribotest, 8, 2, pp. 151-161, (2001)