The effects of different body positions on the accuracy of ultra-short-term heart rate variability indexes

被引:10
|
作者
Holmes C.J. [1 ]
Fedewa M.V. [1 ]
Dobbs W.C. [1 ,2 ]
Liu Y. [1 ]
Flatt A.A. [3 ]
Nakamura F.Y. [4 ]
Esco M.R. [1 ]
机构
[1] Department of Kinesiology, Exercise Physiology Laboratory, The University of Alabama, Tuscaloosa, AL
[2] Department of Exercise & Sport Science, University of Wisconsin – La Crosse, La Crosse, WI
[3] Department of Health Sciences and Kinesiology, Georgia Southern University, Savannah, GA
[4] Department of Medicine and Aging Sciences, “G. d'Annunzio” University of Chieti-Pescara, Chieti
来源
Journal of High Technology Management Research | 2020年 / 31卷 / 01期
关键词
Autonomic modulation; Non-invasive; Parasympathetic activity; Portable devices; Sympathovagal balance;
D O I
10.1016/j.hitech.2020.100375
中图分类号
R318.08 [生物材料学]; Q [生物科学];
学科分类号
07 ; 0710 ; 0805 ; 080501 ; 080502 ; 09 ;
摘要
Purpose: With the increasing popularity of ultra-short heart rate variability (HRV) measurements being utilized with mobile devices outside of controlled, research settings, it is important to determine the proper methodology to ensure accuracy. Therefore, the purpose of this study was to examine the validity of ultra-short-term HRV metrics across three different body positions in recreationally active individuals. Methods: Twenty-six subjects (12 males: 24.1 ± 3.6 yrs., 178.6 ± 6.4 cm, 82.9 ± 8.7 kg; 15 females: 21.3 ± 1.2 yrs., 170.7 ± 10.5 cm, 71.6 ± 18.9 kg) participated in 10-min electrocardiogram recordings in the supine, seated, and standing positions. HRV analysis using a variety of time, frequency, and non-linear parameters were performed following traditional recommendations (i.e., last 5 min of each 10-min recording) and ultra-short-term recordings (i.e., 1-min epoch following a 1-min stabilization period). Results: Slight decreases (e.g., “near perfect” to “very large”) in intraclass correlations (ICC) and increases in the limits of agreement (LOA) were noted for most of the HRV metrics as position changed to sitting and then standing. However, throughout all three positions, the highest ICC values (0.88 to 0.92) and tightest LOA (CE ± 1.96 SD) were displayed in RMSSD. Conclusions: This study supports the use of RMSSD and SD1 for assessing HRV under ultra-short-term recordings of 1 min regardless of position. However, practitioners should be consistent with the preferred position for measurements and not use them interchangeably to reduce potential errors during long-term monitoring. © 2020
引用
收藏
相关论文
共 50 条
  • [1] Suitability of Ultra-Short-Term Heart Rate Variability in Military Trainees
    Alalyan, Mubarak J.
    Alkahtani, Shaea A.
    Habib, Syed Shahid
    Flatt, Andrew A.
    HEALTHCARE, 2020, 8 (04)
  • [2] Ultra-Short-Term Heart Rate Variability is Sensitive to Training Effects in Team Sports Players
    Nakamura, Fabio Y.
    Flatt, Andrew A.
    Pereira, Lucas A.
    Ramirez-Campillo, Rodrigo
    Loturco, Irineu
    Esco, Michael R.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2015, 14 (03) : 602 - 605
  • [3] Ultra-short-term analysis of heart rate variability for epileptic seizures prediction
    Paredes, Alejandro H.
    Buscema, Ignacio A.
    Arguello, Erick J. P.
    2021 IEEE 2ND INTERNATIONAL CONGRESS OF BIOMEDICAL ENGINEERING AND BIOENGINEERING (CI-IB&BI 2021), 2021,
  • [4] The Validity of Ultra-Short-Term Heart Rate Variability during Cycling Exercise
    Tanoue, Yukiya
    Nakashima, Shihoko
    Komatsu, Tomohiro
    Kosugi, Miki
    Kawakami, Saki
    Kawakami, Shotaro
    Michishita, Ryoma
    Higaki, Yasuki
    Uehara, Yoshinari
    SENSORS, 2023, 23 (06)
  • [5] A Critical Review of Ultra-Short-Term Heart Rate Variability Norms Research
    Shaffer, Fred
    Meehan, Zachary M.
    Zerr, Christopher L.
    FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [6] Ultra-short-term heart rate variability during resistance exercise in the elderly
    Areas, G. P. T.
    Caruso, F. C. R.
    Simoes, R. P.
    Castello-Simoes, V
    Jaenisch, R. B.
    Sato, T. O.
    Cabiddu, R.
    Mendes, R.
    Arena, R.
    Borghi-Silva, A.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2018, 51 (06)
  • [7] Ultra-Short-Term Heart Rate Variability Indexes at Rest and Post-Exercise in Athletes: Evaluating the Agreement with Accepted Recommendations
    Esco, Michael R.
    Flatt, Andrew A.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2014, 13 (03) : 535 - 541
  • [8] Is Ultra-Short-Term Heart Rate Variability Valid in Non-static Conditions?
    Kim, Jin Woong
    Seok, Hyeon Seok
    Shin, Hangsik
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [9] Ultra-Short-Term Heart Rate Variability Analysis on Accelerometric Signals from Mobile Phone
    Landreani, Federica
    Morri, Mattia
    Martin-Yebra, Alba
    Casellato, Claudia
    Pavan, Esteban
    Frigo, Carlo
    Caiani, Enrico G.
    2017 IEEE INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2017, : 241 - 244
  • [10] Using Ultra-Short-Term Heart Rate Variability (HRV) Analysis to Track Posture Changes
    Mohammadpoor Faskhodi, Mahtab
    Fernandez-Chimeno, Mireya
    Garcia-Gonzalez, Miguel Angel
    IEEE ACCESS, 2024, 12 : 129994 - 130006