The micro topology and statistical analysis of the forces of walking and failure of an ITAP in a femur

被引:0
|
作者
Langford E. [1 ]
Griffiths C.A. [2 ]
Rees A. [2 ]
Bird J. [3 ]
机构
[1] The Defence Science and Technology Laboratory (DSTL), Fareham
[2] College of Engineering, Swansea University, Swansea
[3] Department of Mechanical Engineering, University of Bath, Bath
关键词
Additive manufacture; ANSYS; ITAP; MATLAB; Micro topology; Prostheses;
D O I
10.3390/mi1203029
中图分类号
学科分类号
摘要
This paper studies the forces acting upon the Intraosseous Transcutaneous Amputation Prosthesis, ITAP, that has been designed for use in a quarter amputated femur. To design in a failure feature, utilising a safety notch, which would stop excessive stress, a, permeating the bone causing damage to the user. To achieve this, the topology of the ITAP was studied using MATLAB and ANSYS models with a wide range of component volumes. The topology analysis identified critical materials and local maximum stresses when modelling the applied loads. This together with additive layer manufacture allows for bespoke prosthetics that can improve patient outcomes. Further research is needed to design a fully functional, failure feature that is operational when extreme loads are applied from any direction. Physical testing is needed for validation of this study. Further research is also recommended on the design so that the a within the ITAP is less than the yield stress, as, of bone when other loads are applied from running and other activities. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] The Micro Topology and Statistical Analysis of the Forces of Walking and Failure of an ITAP in a Femur
    Langford, Euan
    Griffiths, Christian Andrew
    Rees, Andrew
    Bird, Josh
    MICROMACHINES, 2021, 12 (03)
  • [2] Internal forces and moments in the femur during walking
    Duda, GN
    Schneider, E
    Chao, EYS
    JOURNAL OF BIOMECHANICS, 1997, 30 (09) : 933 - 941
  • [3] Internal forces and moments in the femur during walking
    Biomechanics Section, Technical University Hamburg-Harburg, Hamburg, Germany
    不详
    不详
    J. BIOMECH., 9 (933-941):
  • [4] A Statistical Approach for Modeling Individual Vertical Walking Forces
    Pancaldi, Fabrizio
    Bassoli, Elisa
    Milani, Massimo
    Vincenzi, Loris
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [5] The forces in the distal femur and the knee during walking and other activities measured by telemetry
    Taylor, SJG
    Walker, PS
    Perry, JS
    Cannon, SR
    Woledge, R
    JOURNAL OF ARTHROPLASTY, 1998, 13 (04): : 428 - 437
  • [6] Pedestrian detection by walking topology structure analysis
    Zuo, Hang
    Yang, Bo
    Gao, Lin
    Sheng, Peng
    Wang, Jun-Feng
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2010, 21 (05): : 749 - 753
  • [7] ANALYSIS OF FORCES PRODUCING FRACTURES OF THE PROXIMAL END OF THE FEMUR
    HIRSCH, C
    FRANKEL, VH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1960, 42 (03): : 633 - 640
  • [8] ANALYSIS OF MECHANICAL FORCES ACTING ON THE PROXIMAL END OF THE FEMUR
    HIRSCH, C
    ANATOMICAL RECORD, 1960, 136 (02): : 211 - 211
  • [9] Statistical Analysis of Forces Developed by Fingers
    Cotoros, Diana
    Druga, Cornel
    Stanciu, Anca
    2017 IEEE INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2017, : 21 - 24
  • [10] Statistical and engineering analysis of transmission system topology's influence on large autotransformer failure rates
    Gonzalez, R
    Weisberg, S
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59 - PTS I AND II, 1997, 59 : 423 - 427