Experimental study on performance of grouted sleeve connection with surfacing forming under high stress repeated tension-compression load

被引:0
|
作者
Gao Q. [1 ]
Zhao W. [2 ]
机构
[1] School of Civil Engineering, Shenyang Jianzhu University, Shenyang
[2] College of Civil Engineering and Architecture, Zhejiang University, Hangzhou
关键词
Connection performance; Grouted sleeve connection; High stress repeated tension-compression test; Surfacing forming;
D O I
10.14006/j.jzjgxb.2020.0331
中图分类号
学科分类号
摘要
In order to study the mechanical properties and working mechanism of grouted sleeve connection under the high stress repeated tension-compression action, four splice specimens were designed and manufactured by using sleeves with surfacing welding and slotted rebars. The high stress cyclic loading test and uniaxial tensile test were carried out. The results show that the residual deformation of specimens is about 0.1 mm after 20 cycles. The splice has a relatively stable and reliable performance. The high stress repeated tension-compression has no effect on the failure mode and bearing capacity of the splice, but has a certain influence on the deformation performance of the splice. The stiffness of the splice before rebar yielding is reduced by about 40%, and the elongation at failure is increased by about 26%. The strain distribution curve of the steel rebar in the sleeve end section is obviously different under tension and compression. After 20 cycles, the strain values of the rebars in the sleeve end section tend to be the same under the maximum tension load. The high stress repeated tension-compression has no effect on the axial strain and circumferential strain of the sleeve. The restraint effect of the sleeve before the rebar yielding is not obvious. © 2022, Editorial Office of Journal of Building Structures. All right reserved.
引用
收藏
页码:220 / 227
页数:7
相关论文
共 18 条
  • [1] ZHENG Yongfeng, GUO Zhengxing, Experimental study and finite element analysis on the behavior of deformed gout-filled pipe splice, Journal of Building Structures, 37, 3, pp. 94-102, (2016)
  • [2] Technical specification of grout sleeve splicing for rebars: JGJ 335-2015, (2015)
  • [3] Recommendations for Design, Fabrication and Evaluation of Anchorages and Joints in Reinforcing Bars, (2007)
  • [4] Building code requirements for structural concrete and commentary: ACI 318-11, (2011)
  • [5] HENIN E, MORCOUS G., Non-proprietary bar splice sleeve for precast concrete construction, Engineering Structures, 83, pp. 154-162, (2015)
  • [6] BRESLER B, BERTERO V., Behavior of reinforced concrete under repeated load, Journal of the Structural Division, 94, 6, pp. 1567-1592, (1968)
  • [7] ASO T, KANAKUBO T., Study on bond behavior of reinforced concrete under cyclic loading, Paper Collection of Concrete Engineering, 32, 2, pp. 589-594, (2010)
  • [8] LI Rui, ZHENG Yimin, ZHAO Yong, Experimental research on seismic performance of precast concrete columns with 500 MPa reinforcements splicing by grout-filled coupling sleeves, Journal of Building Structures, 37, 5, pp. 255-263, (2016)
  • [9] QIAN Jiaru, PENG Yuanyuan, ZHANG Jingming, Et al., Tests on seismic behavior of precast shear walls with vertical reinforcements spliced by grout sleeve, Building Structure, 41, 2, pp. 1-6, (2011)
  • [10] ZHENG Yongfeng, GUO Zhengxing, Structural performance of innovative grout sleeve splicing for rebars under cyclic loading, Journal of Hunan University(Natural Sciences), 43, 11, pp. 131-140, (2016)