Axial Compressive Behavior of Ultra-high-Strength Steel Fiber-Reinforced Concrete-Filled Square Steel Columns

被引:0
|
作者
Zhang B. [1 ]
Hu H. [2 ,3 ]
Yang Z. [2 ]
机构
[1] CCCC Construction Group Co.,Ltd., Beijing
[2] College of Civil Engineering, Huaqiao University, Xiamen
[3] Key Laboratory for Structural Engineering and Disaster Prevention of Fujian Province, Huaqiao University, Xiamen
关键词
axial compressive behavior; concrete‑filled steel column; ductility; steel fiber‑reinforced concrete; ultra‑high‑strength concrete;
D O I
10.3969/j.issn.1007-9629.2023.05.013
中图分类号
学科分类号
摘要
To study the compressive behavior of ultra‑high‑strength concrete‑filled square steel columns,12 square steel columns filled with ultra‑high‑strength steel fiber‑reinforced concrete were tested under axial compression. The test variables included the yield strength and thickness of the steel column,the strength of the matrix concrete and the content of steel fiber. The results indicate that the addition of steel fiber doesn't change the failure modes of the specimens. For the columns with the concrete compressive strength between 80 MPa and 150 MPa and the confinement index between 0.33 and 1.43,the compressive strength of the concrete in the steel square is close to that of the corresponding unconfined concrete. The effect of the steel fiber on improving the ductility of square concrete‑filled steel columns decreases as the concrete strength and confinement index increases. When the concrete compressive strength is 130 MPa and the confinement index is 0.90,the addition of steel fiber with 1.5% volume content ratio has no effect on improving the ductility of square concrete‑filled steel columns. © 2023 Tongji University. All rights reserved.
引用
收藏
页码:547 / 554
页数:7
相关论文
共 16 条
  • [1] SAKINO K,, NAKAHARA H, MORINO S,, Et al., Behavior of centrally loaded concrete‑filled steel‑tube short columns[J], Journal of Structural Engineering, 130, 2, (2004)
  • [2] XIAO Jianzhuang, YANG Jie, HUANG Yijie, Et al., Experimental study on recycled concrete confined by steel tube under axial compression[J], Journal of Building Structures, 32, 9, (2011)
  • [3] LI Lijian, XU Lihua, CHI Yin, Et al., Fatigue performance of ultra‑high performance concrete containing coarse aggregate under uniaxial cyclic compression[J], Journal of Building Materials, 25, 4, (2022)
  • [4] YANG Liyun, LIN Changyu, ZHANG Fei, Et al., Effect of basalt fiber on failure of reactive powder concrete under uniaxial compression[J], Journal of Building Materials, 25, 5, (2022)
  • [5] WANG Long, CHI Yin, XU Lihua, Et al., Size effect of mechanical properties of hybrid fiber ultra‑high performance concrete[J], Journal of Building Materials, 25, 8, (2022)
  • [6] TAO Z,UY B,, HAN L H,, Et al., Analysis and design of concrete‑filled stiffened thin‑walled steel tubular columns under axial compression[J], Thin‑Walled Structures, 47, 12, (2009)
  • [7] TOKGOZ S,DUNDAR C., Experimental study on steel tubular columns in‑filled with plain and steel fiber reinforced concrete[J], Thin‑Walled Structures, 48, 6, (2010)
  • [8] GULER S, YAVUZ D, AYDIN M., Hybrid fiber reinforced concrete‑filled square stub columns under axial compression[J], Engineering Structures, 198, (2019)
  • [9] HUANG D M,, LIU Z Z,, LU Y Y,, Et al., Behavior of steel‑fiber‑reinforced concrete‑filled square steel tube stub columns under eccentric compression[J], The Structural Design of Tall and Special Buildings, 31, 5, (2022)
  • [10] YAN Yanxiang, XU Lihua, CAI Heng, Et al., Calculation methods of axial bearing capacity of short square UHPC filled high strength steel tubular columns[J], Journal of Building Structures, 40, 12, (2019)