Test research on far-infrared extinction performance of graphene

被引:0
|
作者
Li H. [1 ]
Wang X. [1 ]
Liu Z. [1 ]
Sun S. [2 ]
Dong W. [1 ]
机构
[1] Institute of NBC Defence, Beijing
[2] 32238 Army, Nanjing
关键词
carbon material; graphene; infrared; mass extinction coefficient; smoke screen;
D O I
10.3788/IRLA20220263
中图分类号
学科分类号
摘要
In order to investigate the infrared extinction properties of graphene, graphene was prepared by redox method. The structure of graphene was also confirmed by scanning electron microscope images and X-ray diffraction mapping. The infrared extinction properties of graphene were tested using the smoke box test and potassium bromide compression method, and compared with those of graphite and carbon fibres under the same conditions. The results show that the infrared extinction performance of graphene in the far infrared band is excellent. For the 8-14 μm far infrared band, its average mass extinction coefficient is approximately 2.10 m2/g, which is 2.39 times of that of the the average mass extinction coefficient of graphite and 3.56 times that of carbon fiber under the same conditions, providing better infrared interference than conventional carbon material smoke screens. Potassium bromide press tests also show that graphene exhibits very good infrared extinction in both mid and far infrared bands, outperforming traditional carbon material smoke screens. © 2023 Chinese Society of Astronautics. All rights reserved.
引用
收藏
相关论文
共 21 条
  • [1] Li Y., Research on test method of infrared smoke shielding effect [D], (2020)
  • [2] Liu G S, Guan H, Lv H P, Et al., Effect of diameter graphite particles on infrared & 10.6 μm laser attenuation performance, Chinese Journal of Energetic Materials, 2, pp. 9-12, (2009)
  • [3] Cai W B, Wang N Y, Song D M, Et al., Effect of diameter graphite particles on IR extinction characteristics, Infrared Technology, 25, 5, pp. 68-71, (2003)
  • [4] Zhang J Y, Song X P., Research on application of carbon fiber in interferenceand energetic materials [J], Electro-Optic Technology Application, 37, 1, pp. 40-43, (2022)
  • [5] Appleyard P G., Infrared extinction performance of high aspectratio carbon nanoparticles, Journal of Optics A: Pure and Applied Optics, 8, pp. 101-113, (2006)
  • [6] Wang X Y, Dong W J, Pang M H, Et al., Granular characteristics and infrared extinction coefficients of graphite aerosol, Procedia Engineering, 102, pp. 1238-1244, (2015)
  • [7] Sun Y Y, Wang X Y, Dong W J, Et al., Study on the influence of carbon fiber’s particle size on infrared/millimeter wave interference performance, Infrared and Laser Engineering, 51, 3, (2022)
  • [8] Chen N, Pan G P, Gua H., Study on IR extinction performance of graphite micro-powder smoke in vacuum, Initiators and Pyrotechnics, 3, pp. 34-36, (2007)
  • [9] Ning G T, Li P, Cui Y L, Et al., Flowability and infrared interference properties of modified graphite flake with hydrophobic nano-silica, Chinese Journal of Energetic Materials, 23, 12, pp. 1217-1220, (2015)
  • [10] Zhang D Z., Research on the composite technology and performance of multi-spectrum interference materials, (2012)