A plate-like sensor for the identification of sample viscoelastic properties using contact resonance atomic force microscopy

被引:1
|
作者
Aureli, Matteo [1 ]
Tung, Ryan [1 ]
机构
[1] Department of Mechanical Engineering, University of Nevada, Reno, 1664 N. Virginia Street, Reno,NV,89557, United States
来源
关键词
18;
D O I
10.1115/1.4049538
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Contact force identification using the subharmonic resonance of a contact-mode atomic force microscopy
    Abdel-Rahman, EM
    Nayfeh, AH
    NANOTECHNOLOGY, 2005, 16 (02) : 199 - 207
  • [2] Viscoelastic properties of cells: Modeling and identification by atomic force microscopy
    Ragazzon, Michael R. P.
    Gravdahl, J. Tommy
    Vagia, Marialena
    MECHATRONICS, 2018, 50 : 271 - 281
  • [3] Measurement of Viscoelastic Loss Tangent with Contact Resonance Modes of Atomic Force Microscopy
    Hurley, Donna C.
    Campbell, Sara E.
    Killgore, Jason P.
    Cox, Lewis M.
    Ding, Yifu
    MACROMOLECULES, 2013, 46 (23) : 9396 - 9402
  • [4] Quantitative Viscoelastic Mapping of Polyolefin Blends with Contact Resonance Atomic Force Microscopy
    Yablon, Dalia G.
    Gannepalli, Anil
    Proksch, Roger
    Killgore, Jason
    Hurley, Donna C.
    Grabowski, Jean
    Tsou, Andy H.
    MACROMOLECULES, 2012, 45 (10) : 4363 - 4370
  • [5] Plate geometries for contact resonance atomic force microscopy: Modeling, optimization, and verification
    Aureli, Matteo
    Ahsan, Syed N.
    Shihab, Rafiul H.
    Tung, Ryan C.
    JOURNAL OF APPLIED PHYSICS, 2018, 124 (01)
  • [6] Hydrodynamic corrections to contact resonance atomic force microscopy measurements of viscoelastic loss tangent
    Tung, Ryan C.
    Killgore, Jason P.
    Hurley, Donna C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (07):
  • [7] Intermittent contact resonance atomic force microscopy
    Stan, Gheorghe
    Gates, Richard S.
    NANOTECHNOLOGY, 2014, 25 (24)
  • [8] Viscoelastic Property Mapping with Contact Resonance Force Microscopy
    Killgore, J. P.
    Yablon, D. G.
    Tsou, A. H.
    Gannepalli, A.
    Yuya, P. A.
    Turner, J. A.
    Proksch, R.
    Hurley, D. C.
    LANGMUIR, 2011, 27 (23) : 13983 - 13987
  • [9] Relationship between Q-factor and sample damping for contact resonance atomic force microscope measurement of viscoelastic properties
    Yuya, P. A.
    Hurley, D. C.
    Turner, J. A.
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (11)
  • [10] Contact resonance atomic force microscopy using long elastic tips
    Zimron-Politi, Nadav
    Tung, Ryan C.
    NANOTECHNOLOGY, 2024, 35 (07)