Temporally and spatially resolved X-ray densitometry in a shock tube

被引:0
|
作者
Shaik, R.A. [1 ]
Kastengren, A.L. [2 ]
Tranter, R.S. [3 ]
Lynch, P.T. [1 ]
机构
[1] Shaik, R.A.
[2] Kastengren, A.L.
[3] Tranter, R.S.
[4] Lynch, P.T.
来源
Lynch, P.T. (ptlynch@uic.edu) | 1600年 / Elsevier Inc.卷 / 224期
基金
美国国家科学基金会;
关键词
Shock tubes - Transmissions - X ray absorption spectroscopy - Boundary layer flow - Image reconstruction - Density of gases - Signal to noise ratio;
D O I
暂无
中图分类号
学科分类号
摘要
Gas densities were measured by x-ray absorption spectroscopy to examine spatial inhomogeneity in density behind incident and reflected shock waves in a miniature (12.7 mm bore) high repetition rate shock tube. Shock waves were generated in argon. The pressure and temperature behind the incident shock were P2 ~ 1.72 bar and T2 ~ 800 K, while those behind the reflected shock were P5 ~ 6.5 bar and T5 ~ 1480 K. Time-resolved line-of-sight transmission measurements using x-rays at 9 keV photon energy were made along various axial and transverse locations covering the entire shock tube cross section. The x-ray transmission at each location was converted to pathlength-integrated densities, which in some conditions could be further converted to pathlength-averaged densities. The measured gas densities were compared with those calculated by the normal shock wave relations, and good agreement was found in the pre-shock and immediately behind the incident shock regions. Similar agreement was found for reflected shock conditions very near the endwall. However, increasingly large differences between the measured and calculated gas densities were found as distance from the endwall increased. Reconstruction by Abel inversion allowed time and radially resolved densities to be obtained from the transverse measurements. While the profiles measured in this experiment are of insufficient signal-to noise level and resolution to definitively assign boundary layer thicknesses, future improvements may be able to do this. The radially resolved densities reveal growing sidewall thermal boundary layers in gases behind the reflected shock. These reconstructions were compared with a model of the thermal boundary layer and are consistent with values of the thermal boundary layer thickness being between 0.25 mm and 1 mm at 0.7 ms after shock reflection. © 2020
引用
收藏
页码:136 / 149
相关论文
共 50 条
  • [1] Temporally and spatially resolved X-ray densitometry in a shock tube
    Shaik, R. A.
    Kastengren, A. L.
    Tranter, R. S.
    Lynch, P. T.
    COMBUSTION AND FLAME, 2021, 224 : 136 - 149
  • [2] X-ray diffraction in temporally and spatially resolved biomolecular science
    Helliwell, John R.
    Brink, Alice
    Kaenket, Surasak
    Starkey, Victoria Laurina
    Tanley, Simon W. M.
    FARADAY DISCUSSIONS, 2015, 177 : 429 - 441
  • [3] Spatially resolved X-ray photoelectron spectroscopy
    Blomfield, CJ
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2005, 143 (2-3) : 241 - 249
  • [4] Spatially Resolved X-ray Fluorescence Analysis with a Pyroelectric X-ray Emitter
    So Hatakeyama
    Shinsuke Kunimura
    Nobuharu Sasaki
    Takashi Yamamoto
    Jun Kawai
    Analytical Sciences, 2008, 24 : 847 - 850
  • [5] Spatially resolved X-ray fluorescence analysis with a pyroelectric X-ray emitter
    Hatakeyama, So
    Kunimura, Shinsuke
    Sasaki, Nobuharu
    Yamamoto, Takashi
    Kawai, Jun
    ANALYTICAL SCIENCES, 2008, 24 (07) : 847 - 850
  • [6] Spatially resolved X-ray emission of EQ Pegasi
    Robrade, J
    Ness, JU
    Schmitt, JHMM
    ASTRONOMY & ASTROPHYSICS, 2004, 413 (01) : 317 - 321
  • [7] Spatially resolved x-ray spectroscopy of CsI deposits
    Coluzza, C.
    Almeida, J.
    Berger, H.
    Perez, L.
    Margaritondo, G.
    Paic, G.
    Braem, A.
    Piuz, F.
    Di Mauro, A.
    Nappi, E.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A343 (01): : 152 - 158
  • [8] Spatially resolved X-ray spectroscopy of Vela shrapnel A
    Katsuda, S
    Tsunemi, H
    ASTROPHYSICAL JOURNAL, 2006, 642 (02): : 917 - 922
  • [9] Spatially resolved X-ray excited optical luminescence
    Martinez-Criado, G.
    Alen, B.
    Sans, J. A.
    Homs, A.
    Kieffer, I.
    Tucoulou, R.
    Cloetens, P.
    Segura-Ruiz, J.
    Susini, J.
    Yoo, J.
    Yi, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 284 : 36 - 39
  • [10] Spatially resolved X-ray spectra of NGC 4258
    Yang, Y.
    Li, B.
    Wilson, A. S.
    Reynolds, C. S.
    ASTROPHYSICAL JOURNAL, 2007, 660 (02): : 1106 - 1117