Assessment on credible capacity of hybrid microgrid containing wind/photovoltaic/storage based on sequence operation

被引:0
|
作者
Wu M. [1 ]
Ji Y. [1 ]
Zheng N. [1 ]
Wu H. [2 ]
Pan J. [2 ]
Xu B. [3 ]
机构
[1] China Electric Power Research Institute, Beijing
[2] School of Electrical Engineering and Automation, Hefei University of Technology, Hefei
[3] State Grid Anhui Electric Power Research Institute, Hefei
来源
关键词
Cluster analysis; Distributed power generation; Microgrids; Monte Carlo methods; Wind PV storage;
D O I
10.19912/j.0254-0096.tynxb.2018-1085
中图分类号
学科分类号
摘要
Reliability and credible capacity are the important indices of AC/DC hybrid microgrid. Considering the meteorological conditions classified by cluster analysis, a probabilistic power output model of wind/photovoltaic/storage of the AC/DC hybrid microgrid is established in this paper. A sequential operation theory is proposed to calculate the expected energy not supplied(EENS) value of AC/DC hybrid microgrid. With the iterative method, the credible capacity is solved. And the influence of wind farm/photovoltaic capacity ratio and DC load sensitivity are analyzed. The results are compared with Monte Carlo methods so that the validity and feasibility of the proposed method are verified with the example system. © 2021, Solar Energy Periodical Office Co., Ltd. All right reserved.
引用
收藏
页码:251 / 258
页数:7
相关论文
共 18 条
  • [1] WANG X J, ZHAO B, WU H B, Et al., Optimal sizing analysis of grid-connected AC-DC hybrid microgrid, Automation of electric power systems, 40, 13, pp. 55-62, (2016)
  • [2] ZHAO H Y, ZHAO H S., Analysis on the effect of microgrid access to the power supply reliability of distribution network, Electrical measurement & instrumentation, 53, 8, pp. 7-12, (2016)
  • [3] LUO Y, WANG L J, WANG G., Power network topological analysis based on incidence matrix notation method and loop matrix, Automation of electric power systems, 38, 12, pp. 34-38, (2014)
  • [4] XIE L, XIE K G, HE J, Et al., Reliability evaluation of grid-connected microgrid considering control strategies, Power system protection and control, 41, 15, pp. 102-109, (2013)
  • [5] CUI Y, LI H Q, ZHANG J T, Et al., Capacity evaluation method of clustering PV power plants considering power correlation, Acta energiae solaris sinica, 38, 4, pp. 1039-1044, (2017)
  • [6] DING M, CHU M J, PAN H, Et al., Operation optimization modeling and uncertainty analysis for hybrid AC DC microgrids, Automation of electric power systems, 41, 5, pp. 1-7, (2017)
  • [7] ZHU Y Q, TANG Q., Analysis of factors affecting reliability of hybrid AC/DC, Smart power, 46, 4, pp. 11-15, (2018)
  • [8] ZHANG N, KANG C Q, CHEN Z P, Et al., Wind power credible capacity evaluation model based on sequence operation, Proceedings of the CSEE, 31, 25, pp. 1-9, (2011)
  • [9] KANG C Q, XIA Q, XIANG N D, Et al., Sequence operation theory and its applications, Automation of electric power systems, 26, 17, pp. 6-11, (2002)
  • [10] BAI X., Probabilistic production simulation of wind/photovoltaic/energy storage power system and reliablity of PV-assisted charging station, (2018)