Free flap perfusion prediction by laser doppler flowmetry based time series analysis

被引:0
|
作者
Kodama H. [1 ]
Ishida K. [1 ]
Hirayama H. [1 ]
Kishi K. [1 ]
Miyawaki T. [1 ]
机构
[1] Department of Plastic and Reconstructive surgery, The Jikei University School of Medicine
关键词
ARMA; free flap; laser doppler flowmetry; LSTM; time series analysis;
D O I
10.11239/jsmbe.Annual59.626
中图分类号
学科分类号
摘要
Flap ischemia and consecutive flap loss is an innate complication in reconstructive free flap surgery. With the development of machine learning, time series analysis based flap failure prediction has become possible. With the laser doppler flowmetry pocket device (PocketLDF®) by JMS it has become possible to measure skin perfusion every second. In this trial skin perfusion in addition to blood pressure, pulse and respiratory rate were measured in 3 patients and flap failure prediction based on the Auto-Regressive Moving Average (ARMA) model and the Long Short Term Memory (LSTM) network was conducted. Accurate perfusion prediction with the ARMA model for stationary processes and with the LSTM network for non-stationary processes was possible. In comparison with real time observation by the attending doctor, the ARMA model was able to predict flap ischemia ahead of time. © 2021, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
引用
收藏
页码:628 / 630
页数:2
相关论文
共 50 条
  • [1] A study of perfusion of the distal free-TRAM flap using laser Doppler flowmetry
    Booi, Darren I.
    Debats, Iris B. J. G.
    Boeckx, Willy D.
    van der Hulst, Rene R. W. J.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2008, 61 (03): : 282 - 288
  • [2] Importance of wavelet analysis in laser Doppler flowmetry time series
    Bernjak, Alan
    Stefanovska, Aneta
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4064 - 4067
  • [3] Detrended fluctuation analysis of laser Doppler flowmetry time series
    Esen, Ferhan
    Aydin, Guelsuen Soenmez
    Esen, Hamza
    MICROVASCULAR RESEARCH, 2009, 78 (03) : 314 - 318
  • [4] Fractal dimensions of laser doppler flowmetry time series
    Carolan-Rees, G
    Tweddel, AC
    Naka, KK
    Griffith, TM
    MEDICAL ENGINEERING & PHYSICS, 2002, 24 (01) : 71 - 76
  • [5] ASSESSMENT OF TRAM FLAP PERFUSION USING LASER DOPPLER FLOWMETRY - AN ADJUNCT TO MICROVASCULAR AUGMENTATION
    HALLOCK, GG
    ALTOBELLI, JA
    ANNALS OF PLASTIC SURGERY, 1992, 29 (02) : 122 - 127
  • [6] ANALYSIS OF THE DIMINISHED SKIN PERFUSION IN ELDERLY PEOPLE BY LASER DOPPLER FLOWMETRY
    WEISS, M
    MILMAN, B
    ROSEN, B
    EISENSTEIN, Z
    ZIMLICHMAN, R
    AGE AND AGEING, 1992, 21 (04) : 237 - 241
  • [7] Noninvasive, real time laser Doppler flowmetry in perfusion regions and larger vessels
    Elter, Peter
    Seiter, Eric
    Karch, Torsten
    Stork, Wilhelm
    Mueller-Glaser, Klaus D.
    Lutter, Norbert
    Proceedings of SPIE - The International Society for Optical Engineering, 3570 : 244 - 254
  • [8] ON MONITORING OF FLAP CIRCULATION USING LASER DOPPLER FLOWMETRY
    SVENSSON, H
    SVEDMAN, P
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1984, 3 (3-4): : 436 - 436
  • [9] Noninvasive, real time laser Doppler flowmetry in perfusion regions and larger vessels
    Elter, P
    Seiter, E
    Karch, T
    Stork, W
    Müller-Glaser, KD
    Lutter, N
    BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS, 1999, 3570 : 244 - 254
  • [10] MEASUREMENT OF HEPATIC PERFUSION IN RATS BY LASER DOPPLER FLOWMETRY
    ALMOND, NE
    WHEATLEY, AM
    AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (02): : G203 - G209