Experimental study on an injection-assisted air source heat pump with a novel two-stage variable-speed scroll compressor

被引:0
|
作者
Wang, Jijin [1 ]
Qv, Dehu [2 ]
Ni, Long [1 ]
Yao, Yang [1 ]
机构
[1] School of Architecture, Harbin Institute of Technology, Key Laboratory of Cold Region Urban and Rural Human Settlement Environment Science and Technology, Ministry of Industry and Information Technology, Harbin,150090, China
[2] Department of Building Environment and Energy Application Engineering, School of Civil Engineering, Lanzhou University of Technology, China
来源
基金
中国国家自然科学基金;
关键词
Air source heat pumps - Heating - Temperature - Energy efficiency - Pumps;
D O I
暂无
中图分类号
学科分类号
摘要
Traditional air source heat pumps (ASHPs) with scroll compressors were limited in terms of variable volume ratio. An injection-assisted ASHP using a novel two-stage variable-speed scroll compressor with a variable volume ratio and direct current (DC) speed regulation motor, named IDCAHP, was proposed herein for improving heating performance in cold and/or severely cold regions over wide-range temperature conditions. Experiments focusing on the IDCAHP heating performance under different temperatures and various characteristics of the compressor frequency were performed. Results indicated that the IDCAHP performed well over wide-range temperature conditions. In particular, the discharge pressure decreased steadily with falling ambient temperature, and the discharge temperature of the IDCAHP increased with the rising pressure ratio by less than 82.6 °C at an ambient temperature of −20.0 °C. Additionally, gas injection and increasing the compressor frequency could improve the heating capacity of the IDCAHP. As the ambient temperature was −20.0 °C, the heating capacity reached 68.1% of the nominal condition, and the heating coefficient of performance (COP) and energy efficiency ratio (EER) of the IDCAHP could reach 2.0 and 1.8, respectively. Moreover, the decreasing intermediate pressure improved the heating performance. By contrast, with a common ASHP without gas injection, quasi-two-stage compression air-source heat pump with an economiser (QCAHP-E), quasi-two-stage compression air-source heat pump with a flash tank (QCAHP-F), and two-stage compression air-source heat pump (TCAHP) system, the COP of the IDCAHP increased to 35.0%, 4.2%, 37.6%, and 16.2%, respectively, whereas the discharge temperature decreased to 47.9 °C, 46.5 °C, 62.7 °C, and 40.7 °C, respectively. © 2020 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [1] Experimental study on an injection-assisted air source heat pump with a novel two-stage variable-speed scroll compressor
    Wang, Jijin
    Qv, Dehu
    Ni, Long
    Yao, Yang
    APPLIED THERMAL ENGINEERING, 2020, 176
  • [2] Residential air-source heat pump with refrigerant injection and variable speed compressor: Experimental investigation and compressor modeling
    Dechesne, Bertrand J.
    Tello-Oquendo, Fernando M.
    Gendebien, Samuel
    Lemort, Vincent
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 108 : 79 - 90
  • [3] Experimental study of an improved air-source heat pump system with a novel three-cylinder two-stage variable volume ratio rotary compressor
    Xiao Biao
    Huang Tongyi
    He Lin
    Yan Yan
    Sun Yuying
    Wang Wei
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 343 - 353
  • [4] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector:Design and experimental research
    XU ShuXue&MA GuoYuan Beijing University of Technology
    Science China(Technological Sciences), 2010, (03) : 782 - 788
  • [5] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector: Design and experimental research
    Xu ShuXue
    Ma GuoYuan
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (03) : 782 - 788
  • [6] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector:Design and experimental research
    XU ShuXueMA GuoYuan Beijing University of TechnologyBeijing China
    Science China(Technological Sciences), 2010, 53 (03) : 782 - 788
  • [7] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector: Design and experimental research
    ShuXue Xu
    GuoYuan Ma
    Science China Technological Sciences, 2010, 53 : 782 - 788
  • [8] Application of an Air Source Heat Pump System with a Three-Cylinder Two-Stage Variable Volumn Ratio Rotary Compressor
    Xiao B.
    Yan Y.
    Zhao S.
    Huang T.
    Li X.
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2021, 55 (02): : 188 - 195
  • [9] Optimum compressor cylinder volume ratio for two-stage compression air source heat pump systems
    Jiang, Shuang
    Wang, Shugang
    Jin, Xu
    Yu, Yao
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 77 - 89
  • [10] Research on air-source heat pump coupled with economized vapor injection scroll compressor and ejector
    Xu Shuxue
    Ma Guoyuan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1587 - 1595