Low energy electronic recoils and single electron detection with a liquid Xenon proportional scintillation counter

被引:7
|
作者
Qi, Jianyang [1 ]
Hood, Noah [1 ]
Kopec, Abigail [1 ]
Ma, Yue [1 ]
Xu, Haiwen [1 ]
Zhong, Min [1 ]
Ni, Kaixuan [1 ]
机构
[1] Univ Calif San Diego, Dept Phys, La Jolla, CA 92093 USA
来源
JOURNAL OF INSTRUMENTATION | 2023年 / 18卷 / 07期
基金
美国国家科学基金会;
关键词
Noble liquid detectors (scintillation; ionization; double-phase); Charge transport and multiplication in liquid media; Charge transport; multiplication and electroluminescence in rare gases and liquids; Neutron detectors (cold; thermal; fast neutrons);
D O I
10.1088/1748-0221/18/07/P07027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Liquid xenon (LXe) is a well-studied detector medium to search for rare events in dark matter and neutrino physics. Two-phase xenon time projection chambers (TPCs) can detect electronic and nuclear recoils with energy down to kilo-electron volts (keV). In this paper, we characterize the response of a single-phase liquid xenon proportional scintillation counter (LXePSC), which produces electroluminescence directly in the liquid, to detect electronic recoils at low energies. Our design uses a thin (10-25 mu m diameter), central anode wire in a cylindrical LXe target where ionization electrons, created from radiation particles, drift radially towards the anode, and electroluminescence is produced. Both the primary scintillation (S1) and electroluminescence (S2) are detected by photomultiplier tubes (PMTs) surrounding the LXe target. Up to 17 photons are produced per electron, obtained with a 10 mu m diameter anode wire, allowing for the highly efficient detection of electronic recoils from beta decays of a tritium source down to similar to 1 keV. Single electrons, from photoemission of the cathode wires, are observed at a gain of 1.8 photoelectrons (PE) per electron. The delayed signals following the S2 signals are dominated by single-photon-like hits, without evidence for electron signals observed in the two-phase xenon TPCs. We discuss the potential application of such a LXePSC for reactor neutrino detection via Coherent Elastic Neutrino Nucleus Scattering (CE nu NS).
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Scintillation response of liquid xenon to low energy nuclear recoils
    Aprile, E
    Giboni, KL
    Majewski, P
    Ni, K
    Yamashita, M
    Hasty, R
    Manzur, A
    McKinsey, DN
    PHYSICAL REVIEW D, 2005, 72 (07):
  • [2] LIQUID XENON PROPORTIONAL SCINTILLATION-COUNTER
    MASUDA, K
    TAKASU, S
    DOKE, T
    TAKAHASHI, T
    NAKAMOTO, A
    KUBOTA, S
    SHIBAMURA, E
    NUCLEAR INSTRUMENTS & METHODS, 1979, 160 (02): : 247 - 253
  • [3] Scintillation characteristics for low energy recoils in Liquid Xenon.: Preliminary results
    Lüscher, R
    Akimov, D
    Bewick, A
    Davidge, D
    Dawson, JV
    Howard, AS
    Ivaniouchenkov, I
    Jones, WG
    Joshi, MK
    Kudryavtsev, VA
    Lawson, TB
    Lebendenko, V
    Lehner, MJ
    Lightfoot, PK
    Liubarsky, I
    McMillan, JE
    Peak, CD
    Quenby, JJ
    Spooner, NJC
    Sumner, TJ
    Tovey, DR
    Ward, CK
    IDENTIFICATION OF DARK MATTER, 2001, : 446 - 451
  • [4] Measurements of scintillation efficiency and pulse shape for low energy recoils in liquid xenon
    Akimov, D
    Bewick, A
    Davidge, D
    Dawson, J
    Howard, AS
    Ivaniouchenkov, I
    Jones, WG
    Joshi, J
    Kudryavtsev, VA
    Lawson, TB
    Lebedenko, V
    Lehner, MJ
    Lightfoot, PK
    Liubarsky, I
    Lüscher, R
    McMillan, JE
    Peak, CD
    Quenby, JJ
    Spooner, NJC
    Sumner, TJ
    Tovey, DR
    Ward, CK
    PHYSICS LETTERS B, 2002, 524 (3-4) : 245 - 251
  • [5] Scintillation efficiency for low energy nuclear recoils in liquid xenon dark matter detectors
    Mu, Wei
    Xiong, Xiaonu
    Ji, Xiangdong
    ASTROPARTICLE PHYSICS, 2015, 61 : 56 - 61
  • [6] New measurement of the scintillation efficiency of low-energy nuclear recoils in liquid xenon
    Plante, G.
    Aprile, E.
    Budnik, R.
    Choi, B.
    Giboni, K. -L.
    Goetzke, L. W.
    Lang, R. F.
    Lim, K. E.
    Fernandez, A. J. Melgarejo
    PHYSICAL REVIEW C, 2011, 84 (04):
  • [7] Precision measurements of the scintillation pulse shape for low-energy recoils in liquid xenon
    Hogenbirk, E.
    Aalbers, J.
    Breur, P. A.
    Decowski, M. P.
    van Teutem, K.
    Colijn, A. P.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [8] GAS PROPORTIONAL SCINTILLATION COUNTER WITH XENON AND XENON MIXTURES
    CONDE, CAN
    POLICARPO, AJ
    ALVES, MAF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (03) : 84 - +
  • [9] Position reconstruction in a liquid xenon scintillation chamber for low-energy nuclear recoils and γ-rays
    Neves, F.
    Solovov, V.
    Chepel, V.
    Lopes, M. L.
    da Cunha, J. Pinto
    Lindote, A.
    Silva, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 48 - 52
  • [10] Measurement of light and charge yield of low-energy electronic recoils in liquid xenon
    Goetzke, L. W.
    Aprile, E.
    Anthony, M.
    Plante, G.
    Weber, M.
    PHYSICAL REVIEW D, 2017, 96 (10)