Failure Analysis and Reliability Improvement of Control System of Main Steam Isolation Valve in Nuclear Power Plants

被引:0
|
作者
Li X. [1 ]
机构
[1] China Nuclear Power Operations Management Co., Ltd., Haiyan
来源
关键词
Failure mode analysis; Limit switch; Main steam isolation valve; Reliability improvement; Root-cause analysis;
D O I
10.13832/j.jnpe.2021.01.0138
中图分类号
学科分类号
摘要
The main steam isolation valve is the most important isolation equipment of the steam pipeline between the nuclear island and the conventional island in nuclear power plants. This paper mainly introduced the function and control theory, and the failure mode analysis. Combined with the historical fault statistics, the weak point of the system-limit switch is obtained, and the failure mechanism and root cause analysis of limit switch failure are emphatically expounded. At last, the paper puts forward the improvement measures from five aspects: human, machine, material, method and environment, which has certain reference significance for the maintenance and improvement of the main steam isolation control system of other nuclear power plants in service in China. © 2021, Editorial Board of Journal of Nuclear Power Engineering. All right reserved.
引用
收藏
页码:138 / 142
页数:4