Synergetic control and fault characteristics analysis of hybrid wind farm considering resistance-capacitance crowbar

被引:0
|
作者
Feng H. [1 ]
Shu H. [1 ]
Yang X. [2 ]
Song J. [1 ]
Deng H. [1 ]
Zhou Z. [1 ]
Chen Y. [1 ]
Zhang P. [1 ]
机构
[1] Kunming University of Science and Technology, Kunming
[2] Wuhan University, Wuhan
基金
中国国家自然科学基金;
关键词
cooperative control strategy; hybrid wind farm; resistance-capacitance crowbar; short-circuit current;
D O I
10.19783/j.cnki.pspc.231124
中图分类号
学科分类号
摘要
There is a problem that the low-voltage ride-through measures of a hybrid wind farm are complex and difficult to cooperate with and the fault characteristics after low-voltage ride-through are difficult to analyze. Thus it is proposed that a resistance-capacitance crowbar is applied to the doubly-fed wind turbine to improve the frequency offset and reactive power characteristics of the hybrid wind farm during low-voltage ride-through. First, the models of doubly-fed wind turbine group and permanent magnet direct-drive wind turbine group are established, and a simplified equivalent model of a hybrid wind farm is established by the method of grouping and aggregating equivalence. Then the reactive power regulation ability and regulation characteristics of various types of wind turbines during a fault in the hybrid wind farm considering the resistance-capacitance crowbar are analyzed. The reactive power cooperative control strategy of the hybrid wind farm is formulated to optimize the reactive power output capacity during low voltage ride-through. The short-circuit characteristics of the hybrid wind farm after adopting the cooperative control strategy are analyzed and the short-circuit current is analyzed. Finally, based on PSCAD/EMTDC simulation software, a hybrid wind farm simulation model is established to verify the effectiveness of the collaborative strategy and the correctness of the fault current expression. © 2024 Power System Protection and Control Press. All rights reserved.
引用
收藏
页码:111 / 122
页数:11
相关论文
共 27 条
  • [1] WANG Li, DINH-NHON T., Stability enhancement of a power system with a PMSG-based and a DFIG-based offshore wind farm using a SVC with an adaptive-network based fuzzy inference system, IEEE Transactions on Industrial Electronics, 60, 7, pp. 2799-2807, (2013)
  • [2] CUI Sen, YAN Xiangwu, LI Ruibo, Experimental research on improving the dynamic reactive power coordinated control capability of doubly-fed induction wind turbine, Power System Protection and Control, 50, 8, pp. 117-129, (2022)
  • [3] YANG Yukun, XU Jianzhong, Low voltage ride-through strategy for high-capacity direct-drive wind turbines based on supercapacitor energy storage, Power System Protection and Control, 51, 18, pp. 106-116, (2023)
  • [4] WANG Xiaoyang, ZHENG Di, YANG Guosheng, Et al., Analysis of three-phase short-circuit currents contributed by DFIG in hybrid wind farm, Journal of Chongqing University, 41, 9, pp. 19-29, (2018)
  • [5] LI Hui, ZHAO Bin, SHI Xuyang, Et al., Simulation study on the transient operational performances of a wind farm including different wind turbine generator systems, Power System Protection and Control, 39, 13, pp. 1-7, (2011)
  • [6] FAN Xiaohong, SUN Shiyun, SUN Dejuan, Et al., Analysis of three-phase short-circuit current characteristics of doubly fed induction generator, Power System Protection and Control, 47, 18, pp. 38-48, (2019)
  • [7] FAN Xiaohong, AN Dechao, SUN Shiyun, Et al., Three-Phase short circuit current characteristic analysis of doubly fed induction generator considering crowbar protection action time, Transactions of China Electrotechnical Society, 34, 16, pp. 3444-3452, (2019)
  • [8] JIANG Huilan, LI Xiyu, JIA Yanqi, Et al., Low voltage ride-through control strategy for DFIG under asymmetrical grid voltage drop, Proceedings of the CSU-EPSA, 33, 12, pp. 27-33, (2021)
  • [9] XU Dianguo, WANG Wei, CHEN Ning, Dynamic characteristic analysis of doubly-fed induction generator low voltage ride-through based on crowbar protection, Proceedings of the CSEE, 30, 22, pp. 29-36, (2010)
  • [10] GAO Shuping, YU Kun, SONG Guobing, Calculation and protection method for a three-phase short circuit fault current based on a doubly-fed wind field, Power System Protection and Control, 51, 7, pp. 32-39, (2023)