Pumping test is a fundamental method to determinate aquifer hydraulic parameters. The main evaluated hydraulic parameters are the transmissivity and the aquifer storage coefficient. For estimation of these parameters a semi-logarithmic straight line method is commonly used, which is based on the assumptions of the Theis mathematical model. Nevertheless, there are other parameters corresponding to real conditions during the pumping test, such as the skin effect and the wellbore storage. The evaluation of pumping test data is usually carried out by estimation through curve matching a straight line to drawdown data plotted on a semi-log graph. Neglecting the skin effect and the wellbore storage can lead to false analysis of the time-drawdown variation in the pumping well. Here an evaluation method is developed to estimate the transmissivity, the aquifer storage coefficient, skin effect and wellbore storage from the pumping test data showing this characteristic curve shape. Copyright © 2019 Inderscience Enterprises Ltd.
引用
收藏
页码:1 / 11
页数:10
相关论文
共 50 条
  • [1] Sensitivity analysis of a pumping test on a well with wellbore storage and skin
    Kabala, ZJ
    ADVANCES IN WATER RESOURCES, 2001, 24 (05) : 483 - 504
  • [2] Theoretical evaluation of high-permeability wellbore skin effect on aquifer response under pumping
    Lin, Jun-Hong
    Lin, Ying-Fan
    JOURNAL OF HYDROLOGY, 2024, 641
  • [3] Transient flow to a finite-radius well with wellbore storage and skin effect in a poroelastic confined aquifer
    Fan, Zhiqiang
    Parashar, Rishi
    ADVANCES IN WATER RESOURCES, 2020, 142 (142)
  • [4] Unsteady flow to a partially penetrating pumping well with wellbore storage in a dual-permeability confined aquifer
    Wang, Lei
    Xiang, Yangyue
    Hu, Jianling
    Li, Taotao
    Cai, Chi
    Cai, Jianchao
    JOURNAL OF HYDROLOGY, 2020, 591
  • [5] Determination of skin and aquifer parameters for a slug test with wellbore-skin effect
    Yeh, Hund-Der
    Chen, Yen-Ju
    JOURNAL OF HYDROLOGY, 2007, 342 (3-4) : 283 - 294
  • [6] A Simple Data Analysis Method for a Pumping Test with Skin and Wellbore Storage Effects
    Chen, Chia-Shyun
    Lan, Chuan-Gui
    TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2009, 20 (03): : 557 - 562
  • [7] THE EFFECT OF WELLBORE STORAGE AND SKIN ON INTERFERENCE TEST DATA
    TONGPENYAI, Y
    RAGHAVAN, R
    JOURNAL OF PETROLEUM TECHNOLOGY, 1981, 33 (01): : 151 - 160
  • [8] Pumping test in a confined aquifer under tidal influence
    Chapuis, RP
    Bélanger, C
    Chenaf, D
    GROUND WATER, 2006, 44 (02) : 300 - 305
  • [9] Non-Darcian effect on a sinusoidal pumping test in a leaky confined aquifer
    Li, Yabing
    Zhou, Zhifang
    Zhuang, Chao
    Shen, Qi
    HYDROGEOLOGY JOURNAL, 2023, 31 (04) : 931 - 946
  • [10] Non-Darcian effect on a variable-rate pumping test in a confined aquifer
    Li, Yabing
    Zhou, Zhifang
    Zhuang, Chao
    Huang, Yong
    Wang, Jinguo
    HYDROGEOLOGY JOURNAL, 2020, 28 (08) : 2853 - 2863