Fully automated radiotherapy treatment planning: A scan to plan challenge

被引:4
|
作者
Gooding, Mark J. [1 ,2 ]
Aluwini, Shafak [3 ]
Urbano, Teresa Guerrero [4 ]
McQuinlan, Yasmin [5 ]
Om, Deborah [6 ]
Staal, Floor H. E. [3 ]
Perennec, Tanguy [7 ]
Azzarouali, Sana [8 ]
Cardenas, Carlos E. [9 ]
Carver, Antony [10 ]
Korreman, Stine Sofia [11 ,13 ]
Bibault, Jean-Emmanuel [12 ]
机构
[1] Inpictura Ltd, 5 Chambers, Abingdon OX14 3PX, England
[2] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester M20 4BX, England
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, Groningen, Netherlands
[4] Kings Coll London, Guys & St Thomas NHS Fdn Trust, Sch Canc & Pharmaceut Sci, Dept Clin Oncol, London, England
[5] Mirada Med Ltd, Barclay House 234 Botley Rd, Oxford OX2 0HP, England
[6] Univ Paris Cite, Hop Europeen Georges Pompidou, Dept Med Phys, F-75015 Paris, France
[7] Inst Cancerol Ouest, Dept Radiotherapie, F-44805 Nantes, France
[8] locat Vrije Univ Amsterdam, Amsterdam UMC, Radiat Oncol, De Boelelaan 1117, Amsterdam, Netherlands
[9] Univ Alabama Birmingham, Dept Radiat Oncol, Birmingham, AL USA
[10] Univ Hosp Birmingham NHS Fdn Trust, Dept Med Phys, Birmingham, England
[11] Aarhus Univ, Dept Clin Med, DK-8000 Aarhus, Denmark
[12] Univ Paris Cite, Hop Europeen Georges Pompidou, Dept Radiat Oncol, F-75015 Paris, France
[13] Aarhus Univ Hosp, Danish Ctr Particle Therapy, DK-8200 Aarhus, Denmark
关键词
Autocontouring; Contouring; Autoplanning; Computer assisted radiotherapy planning; Automation; Artificial intelligence; Prostate cancer; Image-guided radiotherapy; MR-GUIDED RADIOTHERAPY; PELVIC LYMPH-NODE; RADIATION-THERAPY; CLINICAL-EVALUATION; PROSTATE-CANCER; GUIDELINES; DELINEATION; ATLAS; PATIENT; BEHALF;
D O I
10.1016/j.radonc.2024.110513
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: Over the past decade, tools for automation of various sub-tasks in radiotherapy planning have been introduced, such as auto-contouring and auto-planning. The purpose of this study was to benchmark what degree of automation is possible. Materials and Methods: A challenge to perform automated treatment planning for prostate and prostate bed radiotherapy was set up. Participants were provided with simulation CTs and a treatment prescription and were asked to use automated tools to produce a deliverable radiotherapy treatment plan with as little human intervention as possible. Plans were scored for their adherence to the protocol when assessed using consensus expert contours. Results: Thirteen entries were received. The top submission adhered to 81.8% of the minimum objectives across all cases using the consensus contour, meeting all objectives in one of the ten cases. The same system met 89.5% of objectives when assessed with their own auto-contours, meeting all objectives in four of the ten cases. The majority of systems used in the challenge had regulatory clearance (Auto-contouring: 82.5%, Auto-planning: 77%). Despite the 'hard' rule that participants should not check or edit contours or plans, 69% reported looking at their results before submission. Conclusions: Automation of the full planning workflow from simulation CT to deliverable treatment plan is possible for prostate and prostate bed radiotherapy. While many generated plans were found to require none or minor adjustment to be regarded as clinically acceptable, the result indicated there is still a lack of trust in such systems preventing full automation.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Is full automation of radiotherapy treatment planning from scan to plan possible?
    Gooding, Mark J.
    Al-Uwini, Shafak
    Guerrero-Urbano, Teresa
    McQuinlan, Yasmin
    Om, Deborah
    Staal, Floor H. E.
    Korreman, Stine
    Bibault, Jean-Eammanuel
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S2888 - S2890
  • [2] Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
    Court, Laurence E.
    Kisling, Kelly
    McCarroll, Rachel
    Zhang, Lifei
    Yang, Jinzhong
    Simonds, Hannah
    du Toit, Monique
    Trauernicht, Chris
    Burger, Hester
    Parkes, Jeannette
    Mejia, Mike
    Bojador, Maureen
    Balter, Peter
    Branco, Daniela
    Steinmann, Angela
    Baltz, Garrett
    Gay, Skylar
    Anderson, Brian
    Cardenas, Carlos
    Jhingran, Anuja
    Shaitelman, Simona
    Bogler, Oliver
    Schmeller, Kathleen
    Followill, David
    Howell, Rebecca
    Nelson, Christopher
    Peterson, Christine
    Beadle, Beth
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (134):
  • [3] Fully automated treatment planning for MLC-based robotic radiotherapy
    Schipaanboord, Bastiaan W. K.
    Gizynska, Marta K.
    Rossi, Linda
    Vries, Kim C.
    Heijmen, Ben J. M.
    Breedveld, Sebastiaan
    MEDICAL PHYSICS, 2021, 48 (08) : 4139 - 4147
  • [4] Fully Automated Multicriteria Optimization (MCO) Treatment Plan Generation for Radiation Treatment Planning
    Kirlik, G.
    D'Souza, W. D.
    Zhang, H. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : S98 - S98
  • [5] Automated Radiotherapy Treatment Planning
    Moore, Kevin L.
    SEMINARS IN RADIATION ONCOLOGY, 2019, 29 (03) : 209 - 218
  • [6] An Initial Plan Check Procedure Specifically Designed for Fully-Automated Treatment Planning
    Court, L.
    McCarroll, R.
    Kisling, K.
    Zhang, L.
    Yang, J.
    Simonds, H.
    du Toit, M.
    Jhingran, A.
    Balter, P.
    Beadle, B.
    MEDICAL PHYSICS, 2017, 44 (06) : 2881 - 2881
  • [7] Fast, high quality, semi-automated and fully-automated prostate radiotherapy treatment planning
    Wheeler, P. A.
    Chu, M.
    Woodley, O.
    Paton, A.
    Maggs, R.
    Lewis, D. G.
    Staffurth, J.
    Spezi, E.
    Millin, A. E.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S768 - S768
  • [8] Benchmarking daily adaptation using fully automated radiotherapy treatment plan optimization for rectal cancer
    Jagt, Thyrza Z.
    Janssen, Tomas M.
    Betgen, Anja
    Wiersema, Lisa
    Verhage, Rick
    Garritsen, Sanne
    Vijlbrief-Bosman, Tineke
    de Ruiter, Peter
    Remeijer, Peter
    Marijnen, Corrie A. M.
    Peters, Femke P.
    Sonke, Jan -Jakob
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 24 : 7 - 13
  • [9] Utilisation of Pareto navigation techniques to calibrate a fully automated radiotherapy treatment planning solution
    Wheeler, Philip A.
    Chu, Michael
    Holmes, Rosemary
    Smyth, Maeve
    Maggs, Rhydian
    Spezi, Emiliano
    Staffurth, John
    Lewis, David G.
    Millin, Anthony E.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 10 : 41 - 48
  • [10] Automated radiotherapy treatment plan integrity verification
    Yang, Deshan
    Moore, Kevin L.
    MEDICAL PHYSICS, 2012, 39 (03) : 1542 - 1551