Unveiling the dynamics of intraoperative contamination in total hip arthroplasty: the discrepancy between particulate and microbial contamination in surgical site infection risk

被引:0
|
作者
Tateiwa, Toshiyuki [1 ]
Masaoka, Toshinori [1 ]
Takahashi, Yasuhito [1 ,2 ]
Ishida, Tsunehito [1 ]
Shishido, Takaaki [1 ]
Yamamoto, Kengo [1 ]
机构
[1] Tokyo Med Univ, Dept Orthoped Surg, 6-7-1 Nishishinjuku,Shinjuku Ku, Tokyo 1600023, Japan
[2] Tokyo Med Univ, Dept Bone & Joint Biomat Res, 6-7-1 Nishishinjuku,Shinjuku Ku, Tokyo 1600023, Japan
关键词
Total hip arthroplasty; Surgical site infection; Space suits; Particle contamination; Microbial contamination; LAMINAR AIR-FLOW; OPERATING-ROOM; KNEE REPLACEMENT; POSTOPERATIVE INFECTION; DEEP INFECTION; JOINT; VENTILATION; PREVENTION; QUALITY; COUNTS;
D O I
10.1186/s42836-024-00272-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundSurgical site infection (SSI) is a major problem following total hip arthroplasty (THA). This study investigated the impact of a standard intraoperative routine where the surgical team wears full-body exhaust suits (space suits) within a laminar airflow (LAF)-ventilated operating room (OR) on environmental contamination. Our primary objective was to identify potential modifiable intraoperative factors that could be better controlled to minimize SSI risk.MethodsWe implemented an approach involving simultaneous and continuous air sampling throughout actual primary cementless THA procedures. This method concurrently monitored both airborne particle and microbial contamination levels from the time the patient entered the OR for surgery until extubation.ResultsAirborne particulate and microbial contamination significantly increased during the first and second patient repositionings (postural changes) when the surgical team was not wearing space suits. However, their concentration exhibited inconsistent changes during the core surgical procedures, between incision and suturing, when the surgeons wore space suits. The microbial biosensor detected zero median microbes from draping to suturing. In contrast, the particle counter indicated a significant level of airborne particles during head resection and cup press-fitting, suggesting these procedures might generate more non-viable particles.ConclusionsThis study identified a significant portion of airborne particles during the core surgical procedures as non-viable, suggesting that monitoring solely for particle counts might not suffice to estimate SSI risk. Our findings strongly support the use of space suits for surgeons to minimize intraoperative microbial contamination within LAF-ventilated ORs. Therefore, minimizing unnecessary traffic and movement of unsterile personnel is crucial. Additionally, since our data suggest increased contamination during patient repositioning, effectively controlling contamination during the first postural change plays a key role in maintaining low microbial contamination levels throughout the surgery. The use of sterile gowns during this initial maneuver might further reduce SSIs. Further research is warranted to investigate the impact of sterile attire on SSIs.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Environment of care: Is it time to reassess microbial contamination of the operating room air as a risk factor for surgical site infection in total joint arthroplasty?
    Parvizi, Javad
    Barnes, Sue
    Shohat, Noam
    Edmiston, Charles E., Jr.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2017, 45 (11) : 1267 - 1272
  • [2] Contamination rate of the surgical gowns during total hip arthroplasty
    Ianiv Klaber
    Pablo Ruiz
    Daniel Schweitzer
    Maria Jesus Lira
    Eduardo Botello
    Aniela Wozniak
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 1015 - 1019
  • [3] Contamination rate of the surgical gowns during total hip arthroplasty
    Klaber, Ianiv
    Ruiz, Pablo
    Schweitzer, Daniel
    Jesus Lira, Maria
    Botello, Eduardo
    Wozniak, Aniela
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (07) : 1015 - 1019
  • [5] Directed Air Flow to Reduce Airborne Particulate and Bacterial Contamination in the Surgical Field During Total Hip Arthroplasty
    Stocks, Gregory W.
    O'Connor, Daniel P.
    Self, Sean D.
    Marcek, Geoff A.
    Thompson, Brandon L.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (05): : 771 - 776
  • [6] The incidence and risk factors of intraoperative bacterial contamination in primary total knee arthroplasty
    Xing, Lijun
    Liu, Fengyue
    Li, Enrun
    Kang, Yuling
    Tan, Kunyuan
    Li, Juhong
    FRONTIERS IN SURGERY, 2024, 11
  • [7] Microbial Load of Trocars: Potential Source of Contamination and Surgical Site Infection
    Vilas-Boas, Vanessa Aparecida
    Levy, Carlos Emilio
    Pedreira de Freitas, Maria Isabel
    Woo, Kevin
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2018, 32
  • [8] Differences in the Risk Factors for Surgical Site Infection between Total Hip Arthroplasty and Total Knee Arthroplasty in the Korean Nosocomial Infections Surveillance System (KONIS)
    Song, Kyoung-Ho
    Kim, Eu Suk
    Kim, Young Keun
    Jin, Hye Young
    Jeong, Sun Young
    Kwak, Yee Gyung
    Cho, Yong Kyun
    Sung, Joohon
    Lee, Yeong-Seon
    Oh, Hee-Bok
    Kim, Tae Kyun
    Koo, Kyung-Hoi
    Kim, Eui-Chong
    Kim, June Myung
    Choi, Tae Yeol
    Kim, Hyo Youl
    Choi, Hee Jung
    Kim, Hong Bin
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2012, 33 (11): : 1086 - 1093
  • [9] Intraoperative Hypothermia Is Not Associated with Surgical Site Infections after Total Hip or Knee Arthroplasty
    Abugri, Bright Osman
    Matsusaki, Takashi
    Ren, Wanxu
    Morimatsu, Hiroshi
    ACTA MEDICA OKAYAMA, 2022, 76 (06) : 651 - 660
  • [10] RISK FACTORS FOR SURGICAL SITE INFECTION AFTER PRIMARY TOTAL HIP ARTHROPLASTY: A CASE CONTROL STUDY
    Brgoch, M.
    Super, N.
    Pace, N.
    Mayer, J.
    Hopf, H. W.
    WOUND REPAIR AND REGENERATION, 2011, 19 (02) : A16 - A16