A patient-specific auto-planning method for MRI-guided adaptive radiotherapy in prostate cancer

被引:2
|
作者
Liu, Xiaonan [1 ,2 ]
Chen, Xinyuan [1 ]
Chen, Deqi [1 ]
Liu, Yuxiang [1 ]
Quan, Hong [2 ]
Gao, Linrui [1 ]
Yan, Lingling [1 ]
Dai, Jianrong [1 ]
Men, Kuo [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Canc Hosp, Natl Canc Ctr, Natl Clin Res Ctr Canc, Beijing 100021, Peoples R China
[2] Wuhan Univ, Sch Phys & Technol, Wuhan 430072, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
MRI-guided adaptive radiotherapy; Auto-planning; Patient-specific; Dose prediction; Deep learning; IMPLEMENTATION; QUALITY;
D O I
10.1016/j.radonc.2024.110525
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Fast and automated generation of treatment plans is desirable for magnetic resonance imaging (MRI)-guided adaptive radiotherapy (MRIgART). This study proposed a novel patient-specific autoplanning method and validated its feasibility in improving the existing online planning workflow. Materials and methods: Data from 40 patients with prostate cancer were collected retrospectively. A patient-specific auto-planning method was proposed to generate adaptive treatment plans. First, a population dose-prediction model (M-0) was trained using data from previous patients. Second, a patient-specific model (M-ps) was created for each new patient by fine-tuning M-0 with the patient's data. Finally, an auto plan was optimized using the parameters derived from the predicted dose distribution by M-ps. The auto plans were compared with manual plans in terms of plan quality, efficiency, dosimetric verification, and clinical evaluation. Results: The auto plans improved target coverage, reduced irradiation to the rectum, and provided comparable protection to other organs-at-risk. Target coverage for the planning target volume (+0.61 %, P = 0.023) and clinical target volume 4000 (+1.60 %, P < 0.001) increased. V-2900cGy (-1.06 %, P = 0.004) and V-1810cGy (-2.49 %, P < 0.001) to the rectal wall and V-1810cGy (-2.82 %, P = 0.012) to the rectum were significantly reduced. The auto plans required less planning time (-3.92 min, P = 0.001), monitor units (-46.48, P = 0.003), and delivery time (-0.26 min, P = 0.004), and their gamma pass rates (3 %/2 mm) were higher (+0.47 %, P = 0.014). Conclusion: The proposed patient-specific auto-planning method demonstrated a robust level of automation and was able to generate high-quality treatment plans in less time for MRIgART in prostate cancer.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Patient-Specific Daily Updated Deep Learning Auto-Segmentation for MRI-Guided Adaptive Radiotherapy
    Zhang, W.
    Li, Z.
    Peng, Y.
    Yin, Y.
    Zhou, Q.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E108 - E109
  • [2] Patient-specific daily updated deep learning auto-segmentation for MRI-guided adaptive radiotherapy
    Li, Zhenjiang
    Zhang, Wei
    Li, Baosheng
    Zhu, Jian
    Peng, Yinglin
    Li, Chengze
    Zhu, Jennifer
    Zhou, Qichao
    Yin, Yong
    RADIOTHERAPY AND ONCOLOGY, 2022, 177 : 222 - 230
  • [3] An adaptive MR-CT registration method for MRI-guided prostate cancer radiotherapy
    Zhong, Hualiang
    Wen, Ning
    Gordon, James J.
    Elshaikh, Mohamed A.
    Movsas, Benjamin
    Chetty, Indrin J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07): : 2837 - 2851
  • [4] Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer
    Hsu, Shu-Hui
    Han, Zhaohui
    Leeman, Jonathan E.
    Hu, Yue-Houng
    Mak, Raymond H.
    Sudhyadhom, Atchar
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [5] Auto-Planning Using Multicriteria Optimization for Prostate Cancer Radiotherapy
    Huang, K.
    Wang, K.
    Gopal, A.
    Hendershot, J.
    Kusmaul, E.
    Steinberg, M.
    Chen, S.
    Guerrero, M.
    MEDICAL PHYSICS, 2024, 51 (10) : 7654 - 7654
  • [6] MRI-guided prostate adaptive radiotherapy - A systematic review
    McPartlin, A. J.
    Li, X. A.
    Kershaw, L. E.
    Heide, U.
    Kerkmeijere, L.
    Lawton, C.
    Mahmood, U.
    Pos, F.
    van As, N.
    van Herk, M.
    Vesprini, D.
    van Zyp, J. van der Voort
    Tree, A.
    Choudhury, A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (03) : 371 - 380
  • [7] Patient-Specific Deep Learning Auto-Segmentation for MRGuided Adaptive Radiotherapy of Prostate Cancer
    Amad, A.
    Chen, X.
    Hall, W. A.
    Lawton, C. A. F.
    Li, A.
    Paulson, E. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E638 - E639
  • [8] MRI-Guided Radiotherapy for Prostate Cancer: Seeing is Believing
    Westley, Rosalyne L.
    Valle, Luca F.
    Tree, Alison C.
    Kishan, Amar U.
    SEMINARS IN RADIATION ONCOLOGY, 2024, 34 (01) : 45 - 55
  • [9] MRI-guided external beam radiotherapy of prostate cancer
    Van der Heide, U.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S61 - S61
  • [10] MRI-GUIDED RADIOTHERAPY FOR PROSTATE CANCER: A NEW PARADIGM
    Murgic, Jure
    Gregov, Marin
    Mrcela, Iva
    Budanec, Mirjana
    Krengli, Marco
    Frobe, Ana
    Franco, Pierfrancesco
    ACTA CLINICA CROATICA, 2022, 61 : 65 - 70