Ultrasound Examination of the Median Nerve at Different Levels: Inter-rater Reliability Study

被引:0
|
作者
Dede, Burak Tayyip [1 ]
Kilinc, Fatih [1 ]
Oguz, Muhammed [1 ]
Bagcier, Fatih [2 ]
Aytekin, Ebru [1 ]
机构
[1] Univ Hlth Sci Turkey, Istanbul Training & Res Hosp, Clin Phys Med & Rehabil, Istanbul, Turkiye
[2] Univ Hlth Sci Turkey, Basaksehir Cam & Sakura City Hosp, Clin Phys Med & Rehabil, Istanbul, Turkiye
关键词
Ultrasound; reliability; median nerve; CARPAL-TUNNEL-SYNDROME; DIAGNOSIS;
D O I
10.4274/tod.galenos.2023.30164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: In this study, we aimed to investigate the inter-rater reliability of the median nerve, evaluated at different levels by ultrasound (US) in asymptomatic subjects. Materials and Methods: A cross-sectional study. This study included 61 healthy controls. The mediolateral and anteroposterior diameters and cross-sectional area (CSA) of the median nerve at the carpal tunnel inlet were measured. The CSA of the median nerves at the carpal tunnel outlet and forearm level was measured. Flattening ratio, wrist-forearm ratio and wrist-forearm difference were calculated. Results: In the inter-rater comparison of the measurements, there was a statistically significant difference only in the carpal tunnel outlet cross sectional area (p<0.048). There was no statistically significant difference between the observers in terms of other measurements (p>0.05). For the median nerve measurement, agreement was also moderate to good inter-rater reliability [intraclass correlation coefficient (ICC) =0.540.81] except for the forearm cross sectional area, swelling ratio of the medial nerve. For the median nerve forearm cross sectional area, agreement was excellent inter-rater reliability (ICC =0.91). However, for swelling ratio, agreement was poor interrater reliability (ICC =0.27). Conclusion: In this study, US showed to be a reliable tool for measuring median nerve dimensions in asymptomatic subjects.
引用
收藏
页码:44 / 48
页数:5
相关论文
共 50 条
  • [1] Inter-Rater and Intra-Rater Reliability of Sonographic Median Nerve and Wrist Measurements
    Gonzalez-Suarez, Consuelo B.
    Buenavente, Ma Lorraine D.
    Cua, Ronald Christopher A.
    Fidel, Maria Belinda C.
    Cabrera, Jan-Tyrone C.
    Regala, Carina Fatima G.
    JOURNAL OF MEDICAL ULTRASOUND, 2018, 26 (01) : 14 - 23
  • [2] INTER-RATER RELIABILITY OF THE MEDIAN MOTOR NERVE CONDUCTION STUDY; DOES EXPERIENCE PLAY A ROLE?
    Swain, Nathan
    Han, Jay
    Joyce, Nanette
    Lipa, Bethany
    Que Nguyen
    MUSCLE & NERVE, 2014, 50 (04) : 711 - 711
  • [3] Inter-rater reliability of the neurological examination in schizophrenia
    Sanders, RD
    Forman, SD
    Pierri, JN
    Baker, RW
    Kelley, ME
    Van Kammen, DP
    Keshavan, MS
    SCHIZOPHRENIA RESEARCH, 1998, 29 (03) : 287 - 292
  • [4] Testing the Reliability of Inter-Rater Reliability
    Eagan, Brendan
    Brohinsky, Jais
    Wang, Jingyi
    Shaffer, David Williamson
    LAK20: THE TENTH INTERNATIONAL CONFERENCE ON LEARNING ANALYTICS & KNOWLEDGE, 2020, : 454 - 461
  • [5] Inter-rater reliability of the standardised mini mental state examination
    Tehan, J. V.
    Katz, B.
    AUSTRALASIAN JOURNAL ON AGEING, 2016, 35 : 35 - 35
  • [6] Vibration sensibility of the median nerve in a population with chronic whiplash associated disorder: Intra- and inter-rater reliability study
    Tyros, I.
    Soundy, A.
    Heneghan, N. R.
    MANUAL THERAPY, 2016, 25 : 81 - 86
  • [7] OWAS inter-rater reliability
    Lins, Christian
    Fudickar, Sebastian
    Hein, Andreas
    APPLIED ERGONOMICS, 2021, 93
  • [8] AN INTER-RATER RELIABILITY STUDY OF THE BARTHEL INDEX
    ROY, CW
    TOGNERI, J
    HAY, E
    PENTLAND, B
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1988, 11 (01) : 67 - 70
  • [9] ASSESSMENT OF INTER-RATER RELIABILITY
    BEARD, K
    STEWART, DA
    AGE AND AGEING, 1989, 18 (05) : 354 - 354
  • [10] INTER-RATER RELIABILITY FROM THE VIEWPOINT OF THE RATER
    SORENSON, AG
    GROSS, CF
    PERSONNEL AND GUIDANCE JOURNAL, 1957, 35 (06): : 365 - 368