Numerical Study on the Influence of Various Design Variables on the Behavior Characteristics of Oil and Gas in Internal Floating Roof Tanks

被引:0
|
作者
Li, Ji-Chao [1 ]
Liu, Ming [2 ]
Dang, Shi-Wang [1 ]
Hu, Ling-Chong [1 ]
Chen, Guang [1 ]
Zhang, Sheng-Dong [1 ]
Kong, Xiang-Hu [3 ]
Xu, Heng [4 ]
机构
[1] Jining Univ, Sch Mech & Elect Engn, Qufu 273155, Peoples R China
[2] Jining Polytech, Dept Mech & Elect Engn, Jining 272023, Peoples R China
[3] Qufu Sci & Technol Innovat Serv Ctr, Qufu 273155, Peoples R China
[4] Hoseo Univ, Div Mech & Automot Engn, Asan 31499, South Korea
关键词
internal floating roof tank; oil volume fraction; vent; oil and gas diffusion; numerical simulation; RISK-ASSESSMENT; STORAGE TANKS; SIMULATION; EVAPORATION; DISPERSION; CFD; EMISSIONS; ACCIDENTS; RELEASE; MODEL;
D O I
10.3390/en17174336
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the development of the petrochemical industry, the number of storage tanks has continuously increased, exacerbating the issue of oil evaporation losses. Therefore, it is urgent to find efficient and economical measures to reduce oil evaporation losses. This paper establishes a diffusion model for internal floating roof tanks (IFRTs) and uses numerical simulation methods to study the mass fraction distribution, pressure distribution, and the variation patterns of oil vapor inside the tanks at different floating roof heights. The results show that the closer to the top of the tank, the lower the oil vapor mass fraction, and the mass fraction distribution is almost symmetrical. As the floating roof height decreases, the vapor mass fraction in the mixed gas region inside the tank gradually decreases, showing a distribution below the lower explosive limit (LEL), indicating improved safety. Furthermore, the study found that in the benchmark model, the behavior characteristics of gasoline vapor are reflected in the changes in mass fraction, velocity, and pressure distribution, where the oil vapor concentration in the upper part is lower but evenly distributed. By comparing the behavior characteristics of oil vapor inside the tank at different floating roof heights, it was found that the floating roof height significantly affects the diffusion and accumulation of oil vapor. The presence of vents effectively reduces the accumulation of oil vapor concentration, improving the stability and safety inside the tank. For different floating roof height scenarios (such as CASE 1, CASE 2, and CASE 4), the oil vapor behavior characteristics are similar. The study results provide important theoretical support for the future development of oil vapor recovery technologies and the design of enclosed energy-saving recovery devices inside tanks, indicating that optimizing the floating roof height and vent system design can significantly reduce oil evaporation losses.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] SLOSHING BEHAVIOR OF FLOATING-ROOF OIL STORAGE TANKS
    SAKAI, F
    NISHIMURA, M
    OGAWA, H
    COMPUTERS & STRUCTURES, 1984, 19 (1-2) : 183 - 192
  • [2] Internal Wind Pressures and Buckling Behavior of Large Cylindrical Floating-Roof Tanks Under Various Liquid Levels
    Zhao, Yang
    Liu, Qing
    Cai, Shuqi
    Dong, Shilin
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2020, 142 (05):
  • [3] Study sets design limits on floating single-roof tanks
    Noaman, Ahmed Saad
    OIL & GAS JOURNAL, 2017, 115 (04) : 81 - U24
  • [4] Failure characteristics of floating-roof oil storage tanks subjected to blast impact
    Lu, Sheng-Zhuo
    Wang, Wei
    Chen, Wei-Dong
    Baozha Yu Chongji/Explosion and Shock Waves, 2015, 35 (05): : 696 - 702
  • [5] Numerical simulation of thermal response behavior of floating-roof tanks exposed to pool fire
    Wang, Xiuzhen
    Zhou, Kuibin
    Mebarki, Ahmed
    Jiang, Juncheng
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [6] Numerical study on the temperature drop characteristics of waxy crude oil in a double-plate floating roof oil tank
    Wang, Min
    Zhang, Xinyu
    Yu, Guojun
    Li, Jingfa
    Yu, Bo
    Sun, Dongliang
    APPLIED THERMAL ENGINEERING, 2017, 124 : 560 - 570
  • [7] Computational fluid dynamics study of flow around floating-roof oil storage tanks
    Pasley, H
    Clark, C
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2000, 86 (01) : 37 - 54
  • [8] Influence of Wind Deviation Angle on n-Hexane Evaporation Loss of Internal Floating-Roof Tanks
    Huang Weiqiu
    Xu Manlin
    Li Fei
    Ji Hong
    Fang Jie
    ChinaPetroleumProcessing&PetrochemicalTechnology, 2020, 22 (02) : 46 - 55
  • [9] Influence of Wind Deviation Angle on n-Hexane Evaporation Loss of Internal Floating-Roof Tanks
    Weiqiu, Huang
    Manlin, Xu
    Fei, Li
    Hong, Ji
    Jie, Fang
    CHINA PETROLEUM PROCESSING & PETROCHEMICAL TECHNOLOGY, 2020, 22 (02) : 46 - 55
  • [10] Floating-roof steel tanks under harmonic settlement: FE parametric study and design criterion
    赵阳
    曹庆帅
    谢新宇
    Journal of Zhejiang University Science A(Science in Engineering), 2006, (03) : 398 - 406