Determination of Chromium Content in Nickel Base Alloy by Matrix Matching Calibration Method of Inductively Coupled Plasma Atomic Emission Spectrometry

被引:0
|
作者
Liu Jie [1 ]
Tan Sheng-nan [1 ]
Qi Zhen-nan [1 ]
Ren Ling-ling [1 ]
Ge Jing-jing [1 ]
Sun Zhong-hua [1 ]
机构
[1] Hebei HBIS Mat Technol Res Inst Co Ltd, Shijiazhuang 050000, Hebei, Peoples R China
关键词
Coupled plasma atomic emission spectrometry; Matrix matching; Calibration method; Nickel base alloy; Chromium;
D O I
10.3964/j.issn.1000-0593(2024)08-2250-06
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Chromium has multiple roles in nickel-based alloy and has outstanding contributions to increasing the wear resistance of alloy coating. At the same time, chromium can form a dense oxidation protective film under the action of high-temperature gas, which significantly improves the alloy's resistance to high-temperature oxidation and thermal fatigue performance. However, in the case of high chromium content, chromium easily forms harmful phases with titanium, aluminum, molybdenum, and other elements in the alloy and reduces its strength. So, the quasi-determined value of chromium in nickel-base alloy is very important. Nickel base alloy samples are digested by microwave digestion using hydrofluoric acid, hydrochloric acid, and nitric acid. The matrix is matched by inductively coupled plasma atomic emission spectrometry, and the calibration solution is prepared to determine-chromium's net strength in the nickel-base alloy's analysis spectrum line to calculate the content. Given the interference of high-content elements such as Ni, Mo, and Fe in nickel-base alloys on the determination of Cr content, 266. 602 nm with fewer interference elements and moderate sensitivity was selected as the analytical spectral line; the matrix effect and the interference effect of coexisting elements were systematically investigated. When preparing the calibration solution, the elements with content greater than 5% were matched with the same content. Prepare the low standard calibration solution K-1 Cr for the chromium element, prepare the high standard calibration solution K-h (cr) for the chromium element, prepare the sample solution K-s (Cr), and use the ICP-OES spectrometer to determine the net strength of the low standard calibration solution K-1 Cr, the sample solution K-S Cr, and the high standard calibration solution K-h (cr) on the analytical spectrum line in turn, and calculate the chromium content according to the formula. The method's accuracy was evaluated using standard reference materials, and the reliability of the method was verified by comparative analysis using the YS/T 539. 4-2009 standard. The results showed that the limit of detection (LOD) and limit of quantification (LOQ) of the method were 0. 05 and 0. 10 mu g . mL(-1), respectively, and the relative standard deviation (RSD) of the determination result is less than 2. 5%. The relative error (RE) of the comparison analysis result between the measured value and the certified value of the standard reference material is less than 2. 5%. This method is easy to operate and accurate to detect. It broadens the detection range for the determination of chromium content in nickel-based alloys by ICP-OES. The lower detection limit is reduced from 2. 0% to 0. 1%, and the upper limit of detection range is increased from 30% to 33. 5%. It greatly improves the efficiency and accuracy of the detection of chromium content in nickel-base alloys. It is suitable for determining chromium content in various brands of nickel-base alloys.
引用
收藏
页码:2250 / 2255
页数:6
相关论文
共 10 条
  • [1] [蔡群 Cai Qun], 2022, [材料科学与工艺, Material Science and Technology], V30, P28
  • [2] DU Mi-fang, 2019, 冶金分析, V39, P68
  • [3] FENG Feng, Chemical Analysis and Meterage(化学分析计量為2020, V29, P87
  • [4] [李佗 Li Tuo], 2013, [光谱实验室, Chinese Journal of Spectroscopy laboratory], V30, P840
  • [5] Lingxia Li., 2015, Metallurgical Analysis, V35, P6
  • [6] LL Xne-feng, 2004, 、Surface Technology, P37
  • [7] QI Zhen-nan, 2021, Metallurgical Analysis(冶金分析), V41, P87
  • [8] WEL Xiao-lan, CIESC Journal(化工学报), P3182
  • [9] [张旭 Zhang Xu], 2022, [现代化工, Modern Chemical Industry], V42, P1
  • [10] ZHU Bin., 2007, Physical Testing and Chemical Analysis (Part B: Chemical Analysis), V43, P491