Electroanalytical sensing of antidiabetic drug linagliptin by using square-wave voltammetry on the boron-doped diamond electrode

被引:2
|
作者
Barzani, Hemn A. H. [1 ]
Ali, Hoshyar Saadi [2 ]
Yardim, Yavuz [3 ]
机构
[1] Lebanese French Univ, Coll Hlth Sci, Dept Med Lab Sci, Erbil, Iraq
[2] Knowledge Univ, Coll Sci, Dept Med Lab Sci, Kirkuk 44001, Erbil, Iraq
[3] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkiye
来源
MONATSHEFTE FUR CHEMIE | 2024年 / 155卷 / 10期
关键词
Linagliptin; Electrochemical sensing; Square-wave voltammetry; Boron-doped diamond electrode; Drug formulations; ELECTROCHEMICAL DETERMINATION; DOSAGE FORM; PHARMACEUTICALS; SURFACTANT; HPLC;
D O I
10.1007/s00706-024-03229-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This research paper presents an electroanalytical investigation utilizing voltammetry to quantify the antidiabetic drug linagliptin with an unmodified boron-doped diamond electrode. Using cyclic voltammetry, linagliptin exhibited a single, distinct, irreversible oxidation peak at around + 1.03 V (vs. Ag/AgCl) in a 0.1 mol dm-3 phosphate buffer solution at pH 7.4. The square-wave voltammetry technique achieved acceptable linearity at approximately + 0.94 V in PBS (pH 7.4). The methodology demonstrated linearity within the concentration range of 1.0 and 50.0 mu g cm-3 (equivalent to 2.1 x 10-6-1.1 x 10-4 mol dm-3) and yielded a limit of detection of 0.28 mu g cm-3 (equivalent to 5.9 x 10-7 mol dm-3). The investigation of the proposed method's applicability was ultimately conducted through the sensing of linagliptin in drug formulations. The established methodologies can serve as viable alternatives to other analytical techniques due to their cost-effectiveness, user-friendliness, efficiency, and ability to yield reliable and repeatable results.
引用
收藏
页码:927 / 935
页数:9
相关论文
共 50 条
  • [1] Individual and simultaneous electroanalytical sensing of epinephrine and lidocaine using an anodically pretreated boron-doped diamond electrode by square-wave voltammetry
    Pinar, Pinar Talay
    Yardim, Yavuz
    Senturk, Zuhre
    DIAMOND AND RELATED MATERIALS, 2020, 101
  • [2] Square-wave voltammetry determination of aspartame in dietary products using a boron-doped diamond electrode
    Medeiros, Roberta Antigo
    de Carvalho, Adriana Evaristo
    Rocha-Filho, Rorneu C.
    Fatibello-Filho, Orlando
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3195 - 3207
  • [3] Determination of Folic Acid in Pharmaceutical Preparations by Square-Wave Voltammetry Using a Boron-Doped Diamond Electrode
    Cinkova, Kristina
    Satkovska, Petra
    Svorc, L'ubomir
    CHEMICKE LISTY, 2015, 109 (10): : 788 - 793
  • [4] Determination of Coumarin in Mikania glomerata Infusions by Square-Wave Voltammetry Using a Boron-Doped Diamond Electrode
    Nobrega, Denise M.
    Lourenco, Anabel S.
    Fernandes, David Douglas S.
    Lyra, Wellington S.
    Moreira, Edilene D. T.
    Diniz, Paulo Henrique G. D.
    Araujo, Mario C. U.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2022, : 838 - 845
  • [5] The Immunosuppressive drug - Rapamycin - Electroanalytical Sensing Using Boron-Doped Diamond electrode
    Stankovic, Dalibor M.
    Katcher, Kurt
    ELECTROCHIMICA ACTA, 2015, 168 : 76 - 81
  • [6] Electroanalytical determination of promethazine hydrochloride in pharmaceutical formulations on highly boron-doped diamond electrodes using square-wave adsorptive voltammetry
    Ribeiro, Francisco Wirley P.
    Cardoso, Amanda S.
    Portela, Rafael R.
    Lima, Janete E. S.
    Machado, Sergio A. S.
    de Lima-Neto, Pedro
    De Souza, Djenaine
    Correia, Adriana N.
    ELECTROANALYSIS, 2008, 20 (18) : 2031 - 2039
  • [7] Square-Wave Voltammetric Determination of Antihistaminic Drug Hydroxyzine in Pharmaceuticals Using a Boron-doped Diamond Electrode
    Scremin, Jessica
    Sartori, Elen Romao
    ORBITAL-THE ELECTRONIC JOURNAL OF CHEMISTRY, 2016, 8 (03): : 174 - 180
  • [8] Simultaneous determination of paracetamol and penicillin V by square-wave voltammetry at a bare boron-doped diamond electrode
    Svorc, Lubomir
    Sochr, Jozef
    Tomcik, Peter
    Rievaj, Miroslav
    Bustin, Dugan
    ELECTROCHIMICA ACTA, 2012, 68 : 227 - 234
  • [9] Determination of indacaterol from inhaler capsules by square-wave voltammetry at the surface of the boron-doped diamond electrode
    Barzani, Hemn Abdulazeez H.
    Ali, Hoshyar Saadi
    Yardim, Yavuz
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2025, 90 (01) : 77 - 94
  • [10] Determination of benzoylecgonine in synthetic urine samples via square-wave voltammetry with boron-doped diamond electrode
    Gomes Jr, Sidnei B.
    Conceicao, Nathalia S.
    dos Santos, Gabriel F. S.
    Rodrigues, Jose Guilherme A.
    Romao, Wanderson
    Ferreira, Rafael Q.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2025, 29 (03) : 1205 - 1215