A comparison of four decontamination procedures in Reusing healing abutments: An in vitro study

被引:2
|
作者
Naghsh, Narges [1 ]
Hosseini, Arezoo [1 ]
Mogharehabed, Ahmad [1 ]
Yaghini, Jaber [1 ]
Pezeshki, Zahra [1 ]
Khaleghi, Niloofar [1 ]
机构
[1] Isfahan Univ Med Sci, Dent Implants Res Ctr, Sch Dent, Dept Periodont, Esfahan, Iran
关键词
Dental Implants; Decontamination; Titanium; Equipment Reuse; Sterilization; HYDROGEN-PEROXIDE; TITANIUM; SURFACES; SAFE;
D O I
10.1016/j.sdentj.2024.06.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to compare the effect of four decontamination methods on the level of residual contaminants in the re-usage of dental healing abutments. Materials and methods: In this experimental study, 50 used healing abutments were divided into five groups of ten as follows: 1. Control group: healing abutments were submerged in the ultrasonic device then autoclaved at 121 degrees C for 15 min; 2. Hypochlorite group: Same procedure as the control group, but the healing abutments were additionally immersed in 3 % hypochlorite for 20 min; 3. Chlorhexidine group: Same procedure as the control group, but the healing abutments were additionally treated with 12 % chlorhexidine; 4. Air polishing group: Same procedure as the control group, but the healing abutments were subjected to air polishing; 5. Hydrogen peroxide group: Same procedure as the control group, but the healing abutments were additionally exposed to 3 % hydrogen peroxide. Then, all healing abutments were stained with a protein-specific stain, Phloxine B. Five photographs were taken of each healing abutment, with four capturing the body (shank)and one capturing the top. All images were analysed, to measure the stained (contaminated) areas of each sample. The obtained data were analysed using statistical software (significance set at p < 0.05). Results: The one-way ANOVA test indicated that the average percentage of contamination residues on the occlusal surface did not show a significant difference among the five groups: control: 5.5 +/- 2.8, sodium hypochlorite: 4.9 +/- 2.5, Chlorhexidine: 5.3 +/- 2.5, air polisher: 3.1 +/- 1.8 and Hydrogen peroxide: 4.8 +/- 3.1. (p = 0.26). The average percentage of residual contamination on the body surfaces (shank part) was significantly lower in the air polisher (1.7 +/- 1.1) and sodium hypochlorite (2.4 +/- 1.1) groups compared to the other three groups (Control: 6.1 +/- 2.3, Hydrogen peroxide: 4.6 +/- 0.7, Chlorhexidine: 5.4 +/- 2.4) (p < 0.05). Conclusion: The results of this study showed that the use of sodium hypochlorite and air polishing, alongside autoclaving and ultrasonic cleaning, effectively reduced residual contamination on the body surfaces of healing abutments.
引用
收藏
页码:1141 / 1145
页数:5
相关论文
共 50 条
  • [1] Reusing Titanium Healing Abutments: Comparison of Two Decontamination Methods
    Chew, Michelle
    Tompkins, Geoffrey
    Tawse-Smith, Andrew
    Waddell, J. Neil
    Ma, Sunyoung
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (06) : 613 - 618
  • [2] An In Vitro Analysis of Sodium Hypochlorite Decontamination for the Reuse of Implant Healing Abutments
    Almehmadi, Ahmad H.
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (04) : 271 - 279
  • [3] Decontamination of Customized Laser-Microtextured Titanium Abutments: A Comparative In Vitro Study of Different Cleaning Procedures
    Farronato, Davide
    Fumagalli, Davide
    Asa'ad, Farah
    Rasperini, Giulio
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2018, 38 (05) : E87 - E95
  • [4] Efficacy of combined chemical and electrochemical decontamination treatments on contaminated healing abutments and their effect on surface topography: An in vitro study
    Kyaw, Thiha Tin
    Abdou, Ahmed
    Nakata, Hidemi
    Pimkhaokham, Atiphan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (05) : 696 - 708
  • [5] Investigation of different electrochemical cleaning methods on contaminated healing abutments in vitro: an approach for metal surface decontamination
    Kyaw, Thiha Tin
    Hanawa, Takao
    Kasugai, Shohei
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [6] Investigation of different electrochemical cleaning methods on contaminated healing abutments in vitro: an approach for metal surface decontamination
    Thiha Tin Kyaw
    Takao Hanawa
    Shohei Kasugai
    International Journal of Implant Dentistry, 6
  • [7] FREQUENCY OF CONTAMINATION ON USED HEALING ABUTMENTS AFTER STERILIZATION: AN IN VITRO STUDY
    Gul, Meisha
    Zafar, Kamil
    Ghafoor, Robia
    Khan, Farhan Raza
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (01) : e1 - e9
  • [8] AN IN VITRO COMPARISON OF THE ACCURACY OF IMPLANT IMPRESSIONS WITH CODED HEALING ABUTMENTS AND DIFFERENT IMPLANT ANGULATIONS
    Al-Abdullah, Khaled
    Zandparsa, Roya
    Finkelman, Matthew
    Hirayama, Hiroshi
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (02): : 90 - 100
  • [9] Accuracy of torque controllers on healing abutments in implant dentistry-an in vitro study
    Goyal, Varun
    Delgado-Ruiz, Rafael
    Kurtz, Kenneth S.
    Romanos, Georgios E.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (06): : 606 - 610
  • [10] Optimisation of mass casualty decontamination procedures in vitro
    Jones, David R.
    Larner, Joanne
    Price, Shirley C.
    Chilcott, Robert P.
    TOXICOLOGY, 2010, 278 (03) : 363 - 364