Frameless Registration Method Using a Depth Camera for Robot-Assisted Stereotactic Brain Surgery

被引:0
|
作者
Yazan, Ersan [1 ]
Talu, Muhamed Fatih [2 ]
Aydogmus, Omur [3 ]
机构
[1] Adiyaman Univ, Besni Vocat High Sch, Dept Comp Technol, TR-02040 Adiyaman, Turkiye
[2] Inonu Univ, Fac Engn, Dept Comp Engn, TR-44000 Malatya, Turkiye
[3] Firat Univ, Technol Fac, Dept Mechatron Engn, TR-23119 Elazig, Turkiye
关键词
landmark registration; face landmark; stereotactic surgery; brain targeting; random forest; SVD;
D O I
10.18280/ts.410430
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Stereotactic surgery aims to access critical areas of the brain with high accuracy. The classical surgical process requires two separate radiological imaging datasets (MRI-CT) and their precise registration. Additionally, specific anatomical landmarks (AC, PC, TAL) are manually identified by the neurosurgeon in both datasets, and MRI-CT registration is performed using these landmarks. To address the issues of patients' double exposure to radiological imaging and the manual identification of landmarks, this paper proposes aAnew approach based on the registration of facial landmarks. The proposed approach consists of four stages. The first stage involves creating 2D facial masks (MRHead and DHead) from the MRI and depth camera data obtained from the patient. Each mask, automatically generated using Google Mediapipe software, consists of 468 points. In the second stage, the mask points are transformed from 2D to 3D. In the third stage, precise registration of the 3D mask points is achieved using singular value decomposition (SVD) and random forest (RF) methods. In the final stage, using the registration matrix, the robotic arm is guided to reach the desired target point on a 3D-printed head prototype. Using the RF method for MHead and DHead mask registration, we obtained fiducial registration error (FRE) values of 1.633 mm and 1.523 mm, and target registration error (TRE) values of 2.217 mm and 2.164 mm for each patient, respectively. These promising results will form the basis of further developments in fully autonomous brain-targeting software with robotic assistance.
引用
收藏
页码:2013 / 2021
页数:9
相关论文
共 50 条
  • [1] Frameless Robot-Assisted Deep Brain Stimulation Surgery: An Initial Experience
    Ho, Allen L.
    Pendharkar, Arjun V.
    Brewster, Ryan
    Martinez, Derek L.
    Jaffe, Richard A.
    Xu, Linda W.
    Miller, Kai J.
    Halpern, Casey H.
    OPERATIVE NEUROSURGERY, 2019, 17 (04) : 424 - 431
  • [2] Three-Dimensional Structure Light Robot-Assisted Frameless Stereotactic Brain Biopsy
    Chen, Jie
    Cheng, Xing
    Huang, Jiashang
    Luo, Pengren
    Mao, Deqiang
    Yang, Haifeng
    OPERATIVE NEUROSURGERY, 2024, 27 (03) : 309 - 315
  • [3] Frameless Stereotactic Robot-Assisted Subthalamic Nucleus Deep Brain Stimulation: Case Report
    Vadera, Sumeet
    Chan, Alvin
    Lo, Thomas
    Gill, Amandip
    Morenkova, Anna
    Phielipp, Nicolas M.
    Hermanowicz, Neal
    Hsu, Frank P. K.
    WORLD NEUROSURGERY, 2017, 97 : 762.e11 - 762.e14
  • [4] Accuracy of frameless robot-assisted stereoelectroencephalography depth electrode implantation using the neurolocate registration system in paediatric patients
    Kurzbuch, Arthur R.
    Scala, Maria R.
    Cooper, Ben
    Kitchen, John
    Tronnier, Volker
    Ellenbogen, Jonathan
    BRITISH JOURNAL OF NEUROSURGERY, 2024,
  • [5] Feasibility and Accuracy of Robot-Assisted, Stereotactic Biopsy Using 3-Dimensional Intraoperative Imaging and Frameless Registration Tool
    Deboeuf, Louise
    Moiraghi, Alessandro
    Debacker, Clement
    Peeters, Sophie M.
    Simboli, Giorgia Antonia
    Roux, Alexandre
    Dezamis, Edouard
    Oppenheim, Catherine
    Chretien, Fabrice
    Pallud, Johan
    Zanello, Marc
    NEUROSURGERY, 2023, 92 (04) : 803 - 811
  • [6] Frameless robot-assisted stereotactic biopsies for lesions of the brainstem—a series of 103 consecutive biopsies
    Iulia Peciu-Florianu
    Victor Legrand
    Apolline Monfilliette-Djelad
    Claude-Alain Maurage
    Quentin Vannod-Michel
    Serge Blond
    Gustavo Touzet
    Nicolas Reyns
    Journal of Neuro-Oncology, 2022, 157 : 109 - 119
  • [7] Frameless stereotactic brain biopsy: A prospective study on robot-assisted brain biopsies performed on 32 patients by using the RONNA G4 system
    Dlaka, Domagoj
    Svaco, Marko
    Chudy, Darko
    Jerbic, Bojan
    Sekoranja, Bojan
    Suligoj, Filip
    Vidakovic, Josip
    Romic, Dominik
    Raguz, Marina
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (03):
  • [8] Robot-guided frameless stereotactic radio-surgery for brain metastases
    El-Abassi, R.
    Abad, P. Garciarena
    Juarbe, R.
    Tremont-Lukats, I. W.
    Ready, M.
    Swanton, R.
    Gould, E. C.
    Culicchia, F.
    EUROPEAN JOURNAL OF NEUROLOGY, 2009, 16 : 576 - 576
  • [9] The VBH mouthpiece: A registration device for frameless stereotactic surgery
    Bale, RJ
    Martin, A
    Vogele, M
    Freysinger, W
    Springer, P
    Giacomuzzi, SM
    RADIOLOGY, 1997, 205 : 1107 - 1107
  • [10] A Novel Registration Method for Robot-assisted Percutaneous Vertebroplasty
    Cheng, Pengfei
    He, Yongyi
    Xin, Baoquan
    PROCEEDINGS OF 2019 IEEE 7TH INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND NETWORK TECHNOLOGY (ICCSNT 2019), 2019, : 530 - 534