Concrete Bedding Effect on the Behavior of Buried Concrete Pipe: Experimental Investigation

被引:0
|
作者
Dawood, Abbas O. [1 ]
Al-Mosawe, Mosa J. [2 ]
Said, Abdul Muttalib I. [2 ]
机构
[1] Univ Misan, Coll Engn, Dept Civil Engn, Maysan 62001, Iraq
[2] Univ Baghdad, Coll Engn, Dept Civil Engn, Baghdad 10001, Iraq
关键词
Concrete bedding; Buried concrete pipe; Patch loading; Uniform load; Bedding factor; SOIL;
D O I
10.1061/JPSEA2.PSENG-1561
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete pipes both reinforced and unreinforced still serve as efficient subsurface infrastructure, especially when used as culverts and sewer lines. In which its structural performance greatly affected by pipe-soil interaction through installation types. In this study the effect of concrete bedding on the behavior of buried unreinforced concrete pipe is investigated through full-scale experimental testing program which the concrete pipes are embedded in gravelly sand soil that is loose and dense. With thickness of 30 cm over pipe crown and subjected to different surface loadings. Seven standard 300 mm internal diameter precast unreinforced concrete pipes were evaluated in a lab soil box test facility. Two loading conditions are used, namely earth fill that simulated by a uniform loading platform, and wheel load that simulated using a patch loading platform with dimensions of 254x508 mm2 (10x20 in.2), which is used by AASHTO to mimic the wheel load of an HS20 truck. The results demonstrated that controlled installation utilizing dense compaction granular backfill could achieve 70% of the pipe strength acquired by employing the typical concrete bedding of the indirect design approach. For concrete bedding under patch loads, the greatest bedding factor (ratio between the supporting strength of buried concrete pipe to the three-edge bearing test strength) obtained is 4.53. The failure loads of pipes with concrete bedding is greater than pipes with compacted soil bedding by 30% for uniform loading and 43% for patch loading.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Nonlinear Finite-Element-Based Investigation of the Effect of Bedding Thickness on Buried Concrete Pipe
    Abolmaali, Ali
    Kararam, Anupong
    JOURNAL OF TRANSPORTATION ENGINEERING, 2010, 136 (09) : 793 - 799
  • [2] BEHAVIOR OF BURIED CONCRETE PIPE
    DAVIS, RE
    BACHER, AE
    JOURNAL OF THE GEOTECHNICAL ENGINEERING DIVISION-ASCE, 1979, 105 (03): : 444 - 446
  • [3] BEHAVIOR OF BURIED CONCRETE PIPE
    KRIZEK, RJ
    MCQUADE, PV
    JOURNAL OF THE GEOTECHNICAL ENGINEERING DIVISION-ASCE, 1978, 104 (07): : 815 - 836
  • [4] STUDY OF PIPE WITH CONCRETE BEDDING .3.
    OLANDER, HC
    DAVIDSON, JW
    TRANSPORTATION ENGINEERING JOURNAL OF ASCE, 1980, 106 (06): : 631 - 646
  • [5] Segmentation of buried concrete pipe images
    Sinha, SK
    Fieguth, PW
    AUTOMATION IN CONSTRUCTION, 2006, 15 (01) : 47 - 57
  • [6] An Experimental Study on Ground Reinforcement Effect of Concrete and Expansion Mat for Prevention of Buried Pipe Damage
    Park, Jeong-Jun
    Shin, Heesoo
    Yuu, Jungjo
    Hong, Gigwon
    JOURNAL OF THE KOREAN GEOSYNTHETIC SOCIETY, 2019, 18 (01): : 91 - 101
  • [7] Full scale testing of concrete pipe bedding design
    Allouche, EN
    Wong, S
    Baumert, ME
    UNDERGROUND INFRASTRUCTURE RESEARCH: MUNICIPAL, INDUSTRIAL AND ENVIRONMENTAL APPLICATIONS, 2001, : 117 - 124
  • [8] CONCRETE CREEP AND SHRINKAGE AND WIRE RELAXATION IN BURIED PRESTRESSED CONCRETE PIPE
    ZARGHAMEE, MS
    HEGER, FJ
    DANA, WR
    ACI STRUCTURAL JOURNAL, 1990, 87 (05) : 512 - 522
  • [9] Numerical investigation of effect of geotextile and pipe stiffness on buried pipe behavior
    Oner C.
    Bildik S.
    Frost J.D.
    Geomechanics and Engineering, 2023, 34 (06) : 611 - 621
  • [10] BURIED CONCRETE PIPE EMBANKMENT INSTALLATION ANALYSIS
    SELIG, ET
    PACKARD, DL
    JOURNAL OF TRANSPORTATION ENGINEERING-ASCE, 1986, 112 (06): : 576 - 592