摘要
Background. Dental implants are increasingly favored as a therapeutic replacement option for edentulism. Titanium (Ti), due to its excellent biocompatibility and unique osseointegration properties, is commonly used in dental implants. Various surface modifications have been explored to improve osseointegration outcomes. Graphene oxide (GO) is a promising material with various applications. Chitosan, found in the exoskeleton of crustaceans and in marine algae, has several biomedical applications. Silver (Ag) is another promising antibacterial agent that increases permeability and damages the bacterial cell membrane upon binding. Objectives. The present study applied a novel implant surface coating of Ag-decorated GO and chitosan on Ti implants to promote bone formation. We further analyzed the physiochemical and antibacterial properties of this surface coating. Material and methods. A solution was prepared by mixing 3 mL of 1% chitosan solution with 10 mg of Ag-GO nanoparticles (NPs). Titanium metal was heated to 70-80 degrees C on a hotplate and the solution was applied onto Ti to obtain an adhesive surface coating. The coated implant was further analyzed for surface properties, using scanning electron microscopy (SEM), the energy dispersive X-ray (EDX) analysis, the attenuated total reflectance-Fourier transform infrared (ATR-FTIR) technique, and the biocompatibility and corrosion analyses. Results. The SEM analysis revealed a homogenously spread, rough, fibrillar and porous layer of coating on the metal surface. The EDX and ATR-FTIR analyses confirmed the successful coating of the implant surface with Ag-decorated GO and chitosan layers. The cell culture assay demonstrated excellent biocompatibility of the surface coating. The corrosion analysis showed improved corrosion resistance of the developed imdifferentiation and proliferation while maintaining an antimicrobial environment on the implant surface.
引用
收藏
页码:627 / 632
页数:6
相关论文
共 2 条
  • [1] Development, characterisation, biocompatibility, and corrosion analysis of gadolinium and selenium doped bioactive glass surface coating for dental implants
    Ram, Vamshi V.
    Arumugam, Parkavi
    Ali, Saheb
    Yadalam, Pradeep Kumar
    Mosaddad, Seyed Ali
    Heboyan, Artak
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2025, 37 (03) : 462 - 469
  • [2] Silver-Decorated Reduced Graphene Oxide-Sulfonated Polyaniline Ternary Nanocomposite: A Highly Reliable Anti-Corrosion Coating Material for Mild Steel
    Nayak, Saurav Ramesh
    Mohana, Kikkeri Narasimha Shetty
    Rajitha, Kamalon
    Madhusudhana, Ambale Murthy
    Naik, Satishkumar R.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2024, 33 (21) : 11801 - 11814