Efficacy and Safety of Different Hybrid Closed Loop Systems for Automated Insulin Delivery in People With Type 1 Diabetes: A Systematic Review and Network Meta-Analysis

被引:3
|
作者
Di Molfetta, Sergio [1 ]
Di Gioia, Ludovico [1 ]
Caruso, Irene [1 ]
Cignarelli, Angelo [1 ]
Green, Suetonia C. [2 ]
Natale, Patrizia [3 ,4 ,5 ]
Strippoli, Giovanni F. M. [3 ,4 ]
Sorice, Gian Pio [1 ]
Perrini, Sebastio [1 ]
Natalicchio, Annalisa [1 ]
Laviola, Luigi [1 ]
Giorgino, Francesco [1 ]
机构
[1] Univ Bari Aldo Moro, Dept Precis & Regenerat Med & Ionian Area, Sect Internal Med Endocrinol Androl & Metab Dis, Bari, Italy
[2] Univ Otago Christchurch, Dept Med, Christchurch, New Zealand
[3] Univ Bari Aldo Moro, Dept Precis & Regenerat Med & Ionian Area, Bari, Italy
[4] Univ Sydney, Sydney Sch Publ Hlth, Sydney, Australia
[5] Univ Foggia, Dept Med & Surg Sci, Nephrol Dialysis & Transplantat Unit, Foggia, Italy
关键词
automated insulin delivery; hybrid closed loop; Time In Range; type; 1; diabetes; GLYCEMIC CONTROL; CONSISTENCY; METRICS; LIFE;
D O I
10.1002/dmrr.3842
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To compare the efficacy and safety of different hybrid closed loop (HCL) systems in people with diabetes through a network meta-analysis. Methods: We searched MEDLINE, EMBASE, CENTRAL and PubMed for randomised clinical trials (RCTs) enrolling children, adolescents and/or adults with type 1 or type 2 diabetes, evaluating Minimed 670G, Minimed 780G, Control-IQ, CamAPS Fx, DBLG-1, DBLHU, and Omnipod 5 HCL systems against other types of insulin therapy, and reporting time in target range (TIR) as outcome. Results: A total of 28 RCTs, all enrolling people with type 1 diabetes, were included. HCL systems significantly increased TIR compared with subcutaneous insulin therapy without continuous glucose monitoring (SIT). Minimed 780G achieved the highest TIR ahead of Control IQ (mean difference (MD) 5.1%, 95% confidence interval (95% CI) [0.68; 9.52], low certainty), Minimed 670G (MD 7.48%, 95% CI [4.27; 10.7], moderate certainty), CamAPS Fx (MD 8.94%, 95% CI [4.35; 13.54], low certainty), and DBLG1 (MD 10.69%, 95% CI [5.73; 15.65], low certainty). All HCL systems decreased time below target range, with DBLG1 (MD - 3.69%, 95% CI [-5.2; - 5.2; - 2.19], high certainty), Minimed 670G (MD - 2.9%, 95% CI [-3.77; - 3.77; - 2.04], moderate certainty) and Minimed 780G (MD - 2.79%, 95% CI [-3.94; - 3.94; - 1.64], high certainty) exhibiting the largest reductions compared to SIT. The risk of severe hypoglycaemia and diabetic ketoacidosis was similar to other types of insulin therapy. Conclusions: We show a hierarchy of efficacy among the different HCL systems in people with type 1 diabetes, thus providing support to clinical decision-making.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Efficacy and Safety of Automated Insulin Delivery Systems in Patients with Type 1 Diabetes Mellitus: A Systematic Review and Meta-Analysis
    Fan, Wenqi
    Deng, Chao
    Xu, Ruoyao
    Liu, Zhenqi
    Leslie, Richard David
    Zhou, Zhiguang
    Li, Xia
    DIABETES & METABOLISM JOURNAL, 2025, 49 (02) : 235 - 251
  • [2] The impact of closed-loop automated insulin delivery systems on hypoglycaemia awareness in people living with type 1 diabetes: A systematic review and meta-analysis
    Efthymiadis, Agathoklis
    Bastounis, Anastasios
    Liu, Linda
    Bourlaki, Marianthi
    Spinos, Dimitrios
    Tsikopoulos, Konstantinos
    JOURNAL OF DIABETES AND METABOLIC DISORDERS, 2024, 23 (02) : 2251 - 2261
  • [3] Effect of Automated Insulin Delivery on Diabetes Distress in People with Type 1 Diabetes-A Systematic Review and Meta-analysis
    Canha, Dulce
    McMahon, Virginia K.
    Schmitz, Susanne
    Alzaid, Fawaz
    Reznik, Yves V.
    Riveline, Jean-Pierre
    Fagherazzi, Guy
    Aguayo, Gloria A.
    DIABETES, 2024, 73
  • [4] Efficacy of automated insulin delivery (AID) systems in type 1 diabetes: protocol of a systematic review and network meta-analysis of outpatient randomised controlled trials
    Stahl-Pehe, Anna
    Schlesinger, Sabrina
    Kuss, Oliver
    Shokri-Mashhadi, Nafiseh
    Baechle, Christina
    Warz, Klaus-D
    Buerger-Buesing, Jutta
    Holl, Reinhard
    Spoerkel, Olaf
    Rosenbauer, Joachim
    BMJ OPEN, 2023, 13 (10):
  • [5] Automated insulin delivery in pregnant women with type 1 diabetes: a systematic review and meta-analysis
    Yang, Qin
    Hao, Jiayi
    Cui, Huijing
    Yang, Qingqing
    Sun, Feng
    Zeng, Baoqi
    ACTA DIABETOLOGICA, 2025,
  • [6] Efficacy and Safety of Technology in Type 1 Diabetes: A Systematic Review and Network Meta-analysis
    Pease, Anthony J.
    Lo, Clement
    Earnest, Arul
    Kiriakova, Velislava
    Liew, Danny
    Zoungas, Sophia
    DIABETES, 2019, 68
  • [7] A Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
    Peacock, Sofia
    Frizelle, Isolda
    Hussain, Sufyan
    DIABETES THERAPY, 2023, 14 (05) : 839 - 855
  • [8] A Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
    Sofia Peacock
    Isolda Frizelle
    Sufyan Hussain
    Diabetes Therapy, 2023, 14 : 839 - 855
  • [9] Efficacy of the hybrid closed-loop insulin delivery system in children and adolescents with type 1 diabetes: a meta-analysis with trial sequential analysis
    Ferreira, Rafael Oliva Morgado
    Trevisan, Talita
    Pasqualotto, Eric
    Schmidt, Pedro
    Chavez, Matheus Pedrotti
    Watanabe, Janine Midori Figueiredo
    van de Sande-Lee, Simone
    ARCHIVES OF ENDOCRINOLOGY METABOLISM, 2024, 68
  • [10] The efficacy of automated insulin delivery systems in children and adolescents with type 1 diabetes Mellitus: A systematic review and meta-analysis of randomized controlled trials
    Michou, Panagiota
    Gkiourtzis, Nikolaos
    Christoforidis, Athanasios
    Kotanidou, Eleni P.
    Galli-Tsinopoulou, Asimina
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 199