Experimental investigation on post-installed lap splices in ordinary and steel fiber-reinforced concrete

被引:0
|
作者
Croppi, Jose I. [1 ]
Ahrens, Mark Alexander [1 ]
Palmeri, Alessandro [2 ]
Piccinin, Roberto [3 ]
Mark, Peter [1 ]
机构
[1] Ruhr Univ Bochum, Inst Concrete Struct, Univ Str 150, D-44801 Bochum, Germany
[2] Hilti Entwicklungsgesell, Kaufering, Germany
[3] Hilti Corp, Schaan, Liechtenstein
关键词
Post-installed rebar; Bond; Lap splice; Splitting; Steel fiber reinforcement; Fiber-optic sensors; STRENGTH; BOND; BARS; BEHAVIOR; DESIGN; JOINTS; PLAIN;
D O I
10.1617/s11527-024-02450-7
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The design of post-installed lap splices typically relies on provisions derived from cast-in-place reinforcing bars (rebars). However, some bond characteristics of post-installed rebars show significant differences compared to cast-in-place rebars, especially when using high-performance mortars. To quantify the bond strength for design purposes, a sound understanding of differences in bond stress distribution, splitting failure mode, and load transfer mechanisms is crucial. This study offers new experimental evidence on these aspects, focusing on the impact of different high-performance injection mortars, lap lengths, and the incorporation of hooked steel fibers in the concrete. Direct tension tests were conducted on spliced post-installed and cast-in-place rebars. Fiber-optic sensors were used to measure strains quasi-continuously on the rebars, minimizing interference on the bond. The findings reveal that post-installed lap splices yield slightly higher bond strength than their cast-in-place counterparts, mainly due to the higher bond stiffness of the mortars. However, this advantage is limited by the bond behavior of the cast-in-rebar within the post-installed lap splice, particularly in conditions of poor confinement. In ordinary strength concrete, cast-in-place rebars exhibit an approximately constant bond stress distribution, as typically assumed for design purposes; by contrast, post-installed rebars show a pronounced non-linear distribution. Furthermore, an addition of steel fibers alters the bond stress of the rebars, resulting in a non-linear distribution in all cases. The study reveals a 20% increase in bond strength of lap splices in concrete reinforced with 80 kg/m3\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\hbox {kg}/\hbox {m}<^>3$$\end{document} of steel fibers. Moreover, they improve the ductility of bond failure for post-installed lap splices.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Retrofit of Deficient Lap Splices Using Post-Installed Anchors
    Low, Katelyn S.
    Martinez, Gloriana Arrieta
    Wald, David M.
    Bayrak, Oguzhan
    ACI STRUCTURAL JOURNAL, 2018, 115 (06) : 1541 - 1550
  • [2] Investigation on bond in post-installed anchored bars and lap splices subjected to direct tension
    Croppi, Jose I.
    Genesio, Giovacchino
    Piccinin, Roberto
    Casucci, Daniele
    Ahrens, Mark Alexander
    Mark, Peter
    STRUCTURAL CONCRETE, 2023, 24 (05) : 5769 - 5786
  • [3] Experimental investigation of lap splices in externally bonded carbon fiber-reinforced plastic plates
    Stallings, JM
    Porter, NM
    ACI STRUCTURAL JOURNAL, 2003, 100 (01) : 3 - 10
  • [4] Lap splices in steel fiber-reinforced reactive powder concrete beams under dynamic loading
    Husain, Zinah Asaad Abdul
    Ghaddar, Maha Ghalib
    Hamood, Mohammed J.
    4TH INTERNATIONAL CONFERENCE ON BUILDINGS, CONSTRUCTION AND ENVIRONMENTAL ENGINEERING, 2020, 737
  • [5] Tension Lap Splices Strengthened with Ultrahigh-Performance Fiber-Reinforced Concrete
    Dagenais, Marc-Andre
    Massicotte, Bruno
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2015, 27 (07)
  • [6] Cyclic Behavior of Lap Splices Strengthened with Ultrahigh Performance Fiber-Reinforced Concrete
    Dagenais, Marc-Andre
    Massicotte, Bruno
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (02)
  • [7] Static Behavior of Post-Installed High-Strength Large-Bolt Shear Connector with Fabricated Hybrid Fiber-Reinforced Concrete/Ordinary Concrete Deck
    He, Yuliang
    Li, Junjie
    He, Wujian
    Wu, Qiangqiang
    Xiang, Yiqiang
    Yang, Ying
    MATERIALS, 2025, 18 (05)
  • [8] Use of Carbon Fiber-Reinforced Polymer Anchors to Repair and Strengthen Lap Splices of Reinforced Concrete Columns
    Kim, InSung
    Jirsa, James O.
    Bayrak, Oguzhan
    ACI STRUCTURAL JOURNAL, 2011, 108 (05) : 630 - 640
  • [9] Tensile behavior of post-installed anchors in plain and steel fiber-reinforced normal- and high-strength concretes
    Gesoglu, M
    Özturan, T
    Özel, M
    Güneyisi, E