Biomechanical characterization of cadaveric brachial plexus regions using uniaxial tensile tests

被引:1
|
作者
Perruisseau-Carrier, Anne C. [1 ,2 ]
Marco, Yann [3 ]
Fleury, Vadim [3 ]
Jmal, Hamdi [1 ]
Brogan, David M. [4 ]
Forli, Alexandra [2 ]
Bahlouli, Nadia [1 ]
机构
[1] Univ Strasbourg, ICube, UMR 7357, CNRS, F-67000 Strasbourg, France
[2] Grenoble Univ Hosp, Hand Surg Plast & Reconstruct Surg, F-38000 Grenoble, France
[3] CNRS, IRDL Inst Rech Dupuy Lome, UMR 6027, ENSTA Bretagne, Brest, France
[4] Washington Univ St Louis, Dept Orthoped Surg, St. Louis, MO USA
来源
HAND SURGERY & REHABILITATION | 2024年 / 43卷 / 04期
关键词
Brachial plexus; Biomechanics; Peripheral nerves; Tensile test; Stretch injury; PERIPHERAL-NERVE; MECHANICAL-PROPERTIES; FINE-STRUCTURE; INJURIES; ROOTS; RAT;
D O I
10.1016/j.hansur.2024.101747
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: The proximal regions of the brachial plexus (roots, trunks) are more susceptible to permanent damage due to stretch injuries than the distal regions (cords, terminal branches). A better description of brachial plexus mechanical behavior is necessary to better understand deformation mechanisms in stretch injury. The purpose of this study was to model the biomechanical behavior of each portion of the brachial plexus (roots, trunks, cords, peripheral nerves) in a cadaveric model and report differences in elastic modulus, maximum stress and maximum strain. Methods: Eight cadaveric plexi, divided into 47 segments according to regions of interest, underwent cyclical uniaxial tensile tests, using a BOSE (R) Electroforce (R) 3330 and INSTRON (R) 5969 material testing machines, to obtain the stress and strain histories of each specimen. Maximum stress, maximum strain and elastic modulus were extracted from the load-displacement and stress-strain curves. Statistical analyses used 1-way ANOVA with post-hoc Tukey HSD (Honestly Significant Difference) and Mann-Whitney tests. Results: Mean elastic modulus was 8.65 MPa for roots, 8.82 MPa for trunks, 22.44 MPa for cords, and 26.43 MPa for peripheral nerves. Differences in elastic modulus and in maximum stress were statistically significant (p < 0.001) between proximal (roots, trunks) and distal (cords, peripheral nerves) specimens. Conclusions: Proximal structures demonstrated significantly smaller elastic modulus and maximum stress than distal structures. These data confirm the greater fragility of proximal regions of the brachial plexus. (c) 2024 SFCM. Published by Elsevier Masson SAS. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页数:8
相关论文
共 49 条
  • [1] Biomechanical characterization of cadaveric brachial plexus microstructure
    Perruisseau-Carrier, Anne C.
    Marco, Yann
    Fleury, Vadim
    Brogan, David M.
    Forli, Alexandra
    Bahlouli, Nadia
    HAND SURGERY & REHABILITATION, 2024, 43 (04):
  • [2] A Systematic Review of the Tensile Biomechanical Properties of the Neonatal Brachial Plexus
    Orozco, Virginia
    Magee, Rachel
    Balasubramanian, Sriram
    Singh, Anita
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (11):
  • [3] Biomechanical characterization of human temporal muscle fascia in uniaxial tensile tests for graft purposes in duraplasty
    Johann Zwirner
    Benjamin Ondruschka
    Mario Scholze
    Gundula Schulze-Tanzil
    Niels Hammer
    Scientific Reports, 11
  • [4] Biomechanical characterization of human temporal muscle fascia in uniaxial tensile tests for graft purposes in duraplasty
    Zwirner, Johann
    Ondruschka, Benjamin
    Scholze, Mario
    Schulze-Tanzil, Gundula
    Hammer, Niels
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [5] Biomechanical properties of porcine cornea; planar biaxial tests versus uniaxial tensile tests
    Hatami-Marbini, Hamed
    Emu, Md Esharuzzaman
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2025, 166
  • [6] Human dilated ascending aorta: Mechanical characterization via uniaxial tensile tests
    Ferrara, Anna
    Morganti, Simone
    Totaro, Pasquale
    Mazzola, Alessandro
    Auricchio, Ferdinando
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 53 : 257 - 271
  • [7] RUPTURE OF BREAST IMPLANTS: A MECHANICAL ANALYSIS USING UNIAXIAL TENSILE TESTS
    Ramiao, Nilza
    Martins, Pedro
    Fernandes, Antonio Augusto
    Barroso, Maria da Luz
    Santos, Diana
    M2D2015: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS IN DESIGN, 2015, : 1809 - 1812
  • [8] Study on the wrinkling behavior of perforated metallic plates using uniaxial tensile tests
    Tang, Haoxing
    Wen, Tong
    Zhou, Yin
    You, Jianhao
    Ma, Desong
    THIN-WALLED STRUCTURES, 2021, 167
  • [9] Characterization of the strain-induced plastic anisotropy of rolled sheets by using sequences of simple shear and uniaxial tensile tests
    Bouvier, S
    Gardey, B
    Haddadi, H
    Teodosiu, C
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2006, 174 (1-3) : 115 - 126
  • [10] Mechanical Characterization of the Human Abdominal Wall Using Uniaxial Tensile Testing
    Kriener, Kyleigh
    Lala, Raushan
    Homes, Ryan Anthony Peter
    Finley, Hayley
    Sinclair, Kate
    Williams, Mason Kelley
    Midwinter, Mark John
    BIOENGINEERING-BASEL, 2023, 10 (10):