High resolution HLA genotyping with third generation sequencing technology-A multicentre study

被引:1
|
作者
Buhler, Stephane [1 ,2 ]
Norgaard, Maja [3 ]
Steffensen, Rudi [4 ]
Klove-Mogensen, Kirstine [4 ,5 ]
Moller, Bjarne Kuno [3 ]
Grossmann, Rebecca [6 ]
Ferrari-Lacraz, Sylvie [1 ,2 ]
Lehmann, Claudia [6 ]
机构
[1] Geneva Univ Hosp, Transplantat Immunol Unit, Geneva, Switzerland
[2] Geneva Univ Hosp, Dept Diagnost, Natl Reference Lab Histocompatibil, Geneva, Switzerland
[3] Aarhus Univ Hosp, Dept Clin Immunol, Aarhus, Denmark
[4] Aalborg Univ Hosp, Dept Clin Immunol, Aalborg, Denmark
[5] Aalborg Univ, Dept Clin Med, Aalborg, Denmark
[6] Univ Hosp Leipzig, Lab Transplantat Immunol, Leipzig, Germany
关键词
deceased donor typing; donor specific antibody determination; high-resolution typing; HLA-typing; nanopore sequencing; NanoTYPE; single sample HLA-typing; third generation sequencing; HUMAN-LEUKOCYTE ANTIGEN; SURVIVAL;
D O I
10.1111/tan.15632
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Molecular HLA typing techniques are currently undergoing a rapid evolution. While real-time PCR is established as the standard method in tissue typing laboratories regarding allocation of solid organs, next generation sequencing (NGS) for high-resolution HLA typing is becoming indispensable but is not yet suitable for deceased donors. By contrast, high-resolution typing is essential for stem cell transplantation and is increasingly required for questions relating to various disease associations. In this multicentre clinical study, the TGS technique using nanopore sequencing is investigated applying NanoTYPE (TM) kit and NanoTYPER (TM) software (Omixon Biocomputing Ltd., Budapest, Hungary) regarding the concordance of the results with NGS and its practicability in diagnostic laboratories. The results of 381 samples show a concordance of 99.58% for 11 HLA loci, HLA-A, -B, -C, -DRB1, -DRB3, -DRB4, -DRB5, -DQA1, -DQB1, -DPA1 and -DPB1. The quality control (QC) data shows a very high quality of the sequencing performed in each laboratory, 34,926 (97.15%) QC values were returned as 'passed', 862 (2.4%) as 'inspect' and 162 (0.45%) as 'failed'. We show that an 'inspect' or 'failed' QC warning does not automatically lead to incorrect HLA typing. The advantages of nanopore sequencing are speed, flexibility, reusability of the flow cells and easy implementation in the laboratory. There are challenges, such as exon coverage and the handling of large amounts of data. Finally, nanopore sequencing presents potential for applications in basic research within the field of epigenetics and genomics and holds significance for clinical concerns.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A multi-site study employing high resolution HLA genotyping by next generation sequencing
    Holcomb, Cherie L.
    Hoglund, Bryan
    Simen, Birgitte
    Egholm, Michael
    Blake, Lisbeth
    Tyan, Dolly B.
    Pando, Marcelo J.
    Anderson, Matthew W.
    Trachtenberg, Elizabeth
    Ladner, Martha
    White, Shana
    Wassmuth, Ralf
    Bohme, Irena
    Gabriel, Christian
    Proll, Johannes
    Klein, Rolf
    Thiele, Bernhard
    Monos, Dimitri
    Ferriola, Deborah
    Lind, Curt
    Goodridge, Damian
    Sayer, David
    Schmitz-Agheguian, Gudrun
    Erlich, Henry A.
    TISSUE ANTIGENS, 2010, 75 (05): : 536 - 537
  • [2] A multi-site study using high-resolution HLA genotyping by next generation sequencing
    Holcomb, C. L.
    Hoeglund, B.
    Anderson, M. W.
    Blake, L. A.
    Boehme, I.
    Egholm, M.
    Ferriola, D.
    Gabriel, C.
    Gelber, S. E.
    Goodridge, D.
    Hawbecker, S.
    Klein, R.
    Ladner, M.
    Lind, C.
    Monos, D.
    Pando, M. J.
    Proell, J.
    Sayer, D. C.
    Schmitz-Agheguian, G.
    Simen, B. B.
    Thiele, B.
    Trachtenberg, E. A.
    Tyan, D. B.
    Wassmuth, R.
    White, S.
    Erlich, H. A.
    TISSUE ANTIGENS, 2011, 77 (03): : 206 - 217
  • [3] High-resolution, high-throughput HLA genotyping by next-generation sequencing
    Bentley, G.
    Higuchi, R.
    Hoglund, B.
    Goodridge, D.
    Sayer, D.
    Trachtenberg, E. A.
    Erlich, H. A.
    TISSUE ANTIGENS, 2009, 74 (05): : 393 - 403
  • [4] RAPID, HIGH RESOLUTION HLA GENOTYPING USING NANOPORE SEQUENCING
    Clark, Peter M.
    Ferriola, Deborah
    Monos, Dimitri S.
    HUMAN IMMUNOLOGY, 2017, 78 : 90 - 90
  • [5] CLINICAL IMPLEMENTATION OF NEXT-GENERATION DNA SEQUENCING IMPROVES HIGH-RESOLUTION HLA GENOTYPING
    Allen, Elizabeth S.
    Yang, Bing
    Garrett, Jodi
    Yang, Chunlong
    Ball, Edward D.
    Morris, Gerald P.
    HUMAN IMMUNOLOGY, 2017, 78 : 215 - 215
  • [6] A MULTI-SITE STUDY EMPLOYING HIGH RESOLUTION HLA GENOTYPING BY NEXT GENERATION 454 GS FLX SEQUENCING.
    Holcomb, Cherie L.
    Hoeglund, Bryan
    Anderson, Matthew W.
    Blake, Lisbeth A.
    Boehme, Irena
    Egholm, Michael
    Ferriola, Deborah
    Gabriel, Christian
    Goodridge, Damian
    Klein, Rolf
    Ladner, Martha
    Lind, Curt
    Monos, Dimitri
    Pando, Marcelo
    Proell, Johannes
    Sayer, David C.
    Schrnitz-Agheguian, Gudrun
    Simen, Birgitte B.
    Thiele, Bernhard
    Trachtenbere, Elizabeth
    Tyan, Dolly B.
    Wassmuth, Ralf
    White, Shana
    Erlich, Henry A.
    HUMAN IMMUNOLOGY, 2010, 71 : S12 - S12
  • [7] High Throughput Clinical HLA Genotyping By Next Generation Sequencing.
    Yin, Y.
    Lan, J.
    Reed, E.
    Zhang, Q.
    TRANSPLANTATION, 2014, 98 : 263 - 263
  • [8] High Throughput Clinical HLA Genotyping By Next Generation Sequencing.
    Yin, Y.
    Lan, J.
    Reed, E.
    Zhang, Q.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 : 263 - 263
  • [9] HLA Genotyping using Next Generation Sequencing
    Lucan, C.
    Pop, Laura-Ancuta
    Florian, A.
    Pileczki, Valentina
    Petrushev, B.
    Dima, Delia
    Frinc, Ioana
    Berindan-Neagoe, Ioana
    Irimie, A.
    Berce, C.
    Florian, I. -S.
    Bojan, Anca
    Tomuleasa, C.
    ROMANIAN JOURNAL OF INTERNAL MEDICINE, 2016, 54 (02) : 98 - 104
  • [10] HIGH RESOLUTION HLA TYPING OF BLOOD STEM CELL DONORS WITH NEXT GENERATION SEQUENCING TECHNOLOGY
    Hirv, Kaimo
    Nieberle, Ingrid
    Welzmueller, Susanne
    Grumbt, Barbara
    Zacher, Thomas
    Knabe, Hans
    TISSUE ANTIGENS, 2012, 79 (06): : 407 - 408