Investigations of the UVC 222 NM air cleaning system in an air-conditioned room

被引:1
|
作者
Leow, Chee Huan [1 ]
Saw, Lip Huat [1 ]
Low, Foon Siang [1 ]
机构
[1] Univ Tunku Abdul Rahman, Lee Kong Chian Fac Engn & Sci, Kajang 43000, Selangor, Malaysia
关键词
UVGI; Disinfection; Airborne transmission; Indoor air quality;
D O I
10.1016/j.buildenv.2024.111990
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Far-Ultraviolet-C (far-UVC) 222 nm was introduced during the Covid-19 pandemic to disinfect the airborne pathogens, particularly SARS-CoV-2. Although far-UVC 222 nm has shown promising results in surface disinfection, its efficacy in air disinfection remains uncertain due to additional variables in air. This study investigated the efficacy of far-UVC 222 nm UVGI in air disinfection experimentally, using total plate count, and input the measured far-UVC intensity into the computational fluid dynamic model to predict infection risk using the Wells- Riley model. Experimental results indicated that after 1 h of far-UVC irradiation, an equivalent far-UVC dosage of 21.31 J/m2, 2 , airborne bacteria concentration was reduced by 44.4 %-74.1 %, while airborne fungal concentration showed a marginal reduction. In a recirculating air-conditioned room, a 20 W far-UVC fixture installation, referred to as Case 1, demonstrated the highest available dosage of 7.66 % difference compared to Case 2. The use of far-UVC in Case 1 can reduce the risk of infection for the influenza H1N1, SARS-CoV-2, and Mycobacterium tuberculosis by 54.48 %, 60.06 %, and 83.73 %, respectively. The study suggests installing far-UVC near the recirculating air-conditioner supply air jet and away from surrounding walls for optimum effectiveness. These results provide recommendations for alternatives to upper-room UVGI, offering a viable option for continuous room air and surface disinfection.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Outdoor pollutants effect on air quality of air-conditioned room
    Zheng, Jianxiang
    Zhou, Lei
    ADVANCES IN ENERGY SCIENCE AND EQUIPMENT ENGINEERING, 2015, : 1379 - 1384
  • [2] POLLEN STUDIES IN A HOSPITAL AIR-CONDITIONED ROOM
    CHAFEE, FH
    NEW ENGLAND AND REGIONAL ALLERGY PROCEEDINGS, 1985, 6 (02): : 150 - 152
  • [3] DISINFECTING AIR-CONDITIONED AIR
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1962, (5288): : 1357 - +
  • [4] Adaptive PID Control of Indoor Air Quality for an Air-conditioned Room
    Gu, Xiaosong
    Li, Heng
    Zhao, Litie
    Wang, Hanqing
    INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 289 - +
  • [5] Development of air purification system in air-conditioned spaces
    Kwan, CHS
    Chan, DWT
    Law, LKC
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3430 - 3434
  • [6] Gas discrimination in an air-conditioned system
    Sarry, F
    Lumbreras, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (04) : 809 - 812
  • [7] Simulink and bond graph modeling of an air-conditioned room
    Yu, B
    van Paassen, AHC
    SIMULATION MODELLING PRACTICE AND THEORY, 2004, 12 (01) : 61 - 76
  • [8] Determination of the Maximum Air Velocity in the Staying Zone of an Air-Conditioned Room.
    Nielsen, Peter V.
    HLH Heizung Luftung/Klima Haustechnik, 1980, 31 (09): : 324 - 330
  • [9] Ionization of air in an air-conditioned building
    Behounek, F
    Kletschka, J
    NATURE, 1938, 142 : 956 - 956
  • [10] AIR-CONDITIONED HANDPIECE
    KILLILEA, JF
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1945, 32 (15): : 966 - 975